HYRIG can supply the API 6D lift check valve range. The API 6D lift check valve uses a guided disc that lifts off the seat under forward flow and closes rapidly when flow reverses.
Conatct For Details
DetailReview(0)Additional

API 6D Lift Check Valve

HYRIG can supply the API 6D lift check valve range. The API 6D lift check valve uses a guided disc that lifts off the seat under forward flow and closes rapidly when flow reverses. It is specified for systems requiring fast, chatter-free closure, such as compressor discharge lines and high-pressure headers.

Key Facts

  • Design standard: API 6D, BS 1868
  • Pressure class: Class 150 / 300 / 600 / 900
  • Size range: NPS 2-12 (DN 50-300)
  • Disc type: Guided lift disc (piston)
  • Closure: Gravity return (spring assist available on request)
  • Seat: Metal-seated, hard alloy overlay
  • End connections: RF, RTJ, BW
  • Testing: API 598, API 6D

Key Specifications

NPSDNClass 150 L RF (mm)Class 150 H (mm)Class 150 Wt (kg)Class 300 L RF (mm)Class 300 H (mm)Class 300 Wt (kg)
2502031401526714026
3802411682831817850
41002921944235619586
615040622675445245180
8200495250118533280220
10250622275194622336310
12300699332320711380510

Dimensions

DimensionStandard
Face-to-face (RF)ASME B16.10
Face-to-face (RTJ)ASME B16.10
Face-to-face (BW)ASME B16.10
Flanged endsASME B16.5 (Class 150-900)
Butt weld endsASME B16.25
Pressure-temperature ratingASME B16.34
Wall thicknessAPI 600 / BS 1868

Structure and Working Principle

Unlike the swing check valve, which relies on a hinged disc moving through a long arc, the lift check valve uses a disc guided by a central stem or body bore. When forward flow enters, the disc lifts vertically off the seat. When flow stops or reverses, the disc drops back into the seat.

The short, linear travel of the guided disc results in fast, non-slam closure. This design is ideal for lines subject to flow reversal or pulsation, reducing the risk of water hammer compared to a large swing check valve. Because the flow path changes direction inside the valve, the pressure drop is generally higher than that of a full-bore swing valve.

Cross-Reference and Replacement

Replacing a swing check valve with a lift check valve? Verify these factors:

  1. Pressure drop: Lift valves have a higher pressure drop. Ensure the system pump or compressor has enough head margin.
  2. Installation orientation: Standard lift check valves are typically installed in horizontal lines. For vertical lines, confirm if a spring-assisted design is required to ensure proper closure.
  3. Face-to-face: Both follow ASME B16.10, but confirm the L dimension as lift valves may differ from swing valves in the same pressure class.
  4. Pulsating flow: If the system experiences reciprocating pump or compressor surges, the lift check valve is the preferred choice to prevent chatter.

Applications

  • Compressor discharge lines: Fast closure prevents backflow into the compressor and resists flow pulsation.
  • Boiler feedwater systems: Reliable non-return protection for high-pressure, high-temperature water.
  • Reciprocating pump lines: Minimizes water hammer caused by rapid flow reversal.
  • High-pressure headers: Provides tight shutoff in Class 600 and Class 900 systems.

Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation. Water hammer risk must be assessed for the specific piping system.

Frequently Asked Questions

Q: Why is a lift check valve better for pulsating flow?

The short linear travel of the guided disc allows it to close quickly before reverse flow develops. A swing check valve's long arc travel can result in chatter and slamming in pulsating conditions.

Q: What is the pressure drop difference compared to a swing check?

A lift check valve has a higher pressure drop because the flow must change direction around the disc. A swing check valve is closer to a full-bore straight path.

Q: Can it be installed vertically?

Standard gravity lift check valves are typically for horizontal installation. For vertical upward flow, a spring-assisted lift check valve is recommended.

Q: What is the typical lead time?

Standard lead time is 4 to 6 weeks depending on size, class, material, and end connection.

Selection Support

To determine if a lift check valve is suitable for your system, provide the flow rate, pressure class, installation orientation, and pump/compressor details. Our engineers will confirm the sizing and closure design.

Contact

For API 6D lift check valve selection, contact HYRIG: info@hyrig.com

Related Pages

Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit