HYRIG can supply the API 6D lift check valve range. The API 6D lift check valve uses a guided disc that lifts off the seat under forward flow and closes rapidly when flow reverses. It is specified for systems requiring fast, chatter-free closure, such as compressor discharge lines and high-pressure headers.
| NPS | DN | Class 150 L RF (mm) | Class 150 H (mm) | Class 150 Wt (kg) | Class 300 L RF (mm) | Class 300 H (mm) | Class 300 Wt (kg) |
|---|---|---|---|---|---|---|---|
| 2 | 50 | 203 | 140 | 15 | 267 | 140 | 26 |
| 3 | 80 | 241 | 168 | 28 | 318 | 178 | 50 |
| 4 | 100 | 292 | 194 | 42 | 356 | 195 | 86 |
| 6 | 150 | 406 | 226 | 75 | 445 | 245 | 180 |
| 8 | 200 | 495 | 250 | 118 | 533 | 280 | 220 |
| 10 | 250 | 622 | 275 | 194 | 622 | 336 | 310 |
| 12 | 300 | 699 | 332 | 320 | 711 | 380 | 510 |
| Dimension | Standard |
|---|---|
| Face-to-face (RF) | ASME B16.10 |
| Face-to-face (RTJ) | ASME B16.10 |
| Face-to-face (BW) | ASME B16.10 |
| Flanged ends | ASME B16.5 (Class 150-900) |
| Butt weld ends | ASME B16.25 |
| Pressure-temperature rating | ASME B16.34 |
| Wall thickness | API 600 / BS 1868 |
Unlike the swing check valve, which relies on a hinged disc moving through a long arc, the lift check valve uses a disc guided by a central stem or body bore. When forward flow enters, the disc lifts vertically off the seat. When flow stops or reverses, the disc drops back into the seat.
The short, linear travel of the guided disc results in fast, non-slam closure. This design is ideal for lines subject to flow reversal or pulsation, reducing the risk of water hammer compared to a large swing check valve. Because the flow path changes direction inside the valve, the pressure drop is generally higher than that of a full-bore swing valve.
Replacing a swing check valve with a lift check valve? Verify these factors:
Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation. Water hammer risk must be assessed for the specific piping system.
Q: Why is a lift check valve better for pulsating flow?
The short linear travel of the guided disc allows it to close quickly before reverse flow develops. A swing check valve's long arc travel can result in chatter and slamming in pulsating conditions.
Q: What is the pressure drop difference compared to a swing check?
A lift check valve has a higher pressure drop because the flow must change direction around the disc. A swing check valve is closer to a full-bore straight path.
Q: Can it be installed vertically?
Standard gravity lift check valves are typically for horizontal installation. For vertical upward flow, a spring-assisted lift check valve is recommended.
Q: What is the typical lead time?
Standard lead time is 4 to 6 weeks depending on size, class, material, and end connection.
To determine if a lift check valve is suitable for your system, provide the flow rate, pressure class, installation orientation, and pump/compressor details. Our engineers will confirm the sizing and closure design.
For API 6D lift check valve selection, contact HYRIG: info@hyrig.com
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.