HYRIG can supply API check valves. This FAQ addresses common engineering and procurement questions regarding swing and lift check valve installation, testing, and sizing.
Q: How do I choose between a swing check valve and a lift check valve?
Swing check valves are best for horizontal lines with steady flow and low pressure drop requirements. Lift check valves are better for pulsating flow (like compressor discharge) because their guided disc closes faster, preventing water hammer.
Q: Can a swing check valve be installed vertically?
Yes, but only for upward flow. Downward-flow vertical installation is not standard and requires a special design. Lift check valves are typically used horizontally.
Q: What causes water hammer in check valves?
Water hammer occurs when a check valve closes slowly, allowing reverse flow to build up momentum before the disc slams shut. Swing valves are prone to this at high velocities; lift valves or damped swing designs mitigate the risk.
Q: What is the purpose of the gasket in high-pressure classes?
For Class 150 and 300, a stainless steel and flexible graphite spiral wound gasket is standard. For Class 900 and above, a ring joint gasket (RTJ) or a pressure-seal bonnet design is used to ensure a tight seal under high pressure.
Q: What is the typical lead time for API check valves?
Standard lead time is 4 to 6 weeks depending on the valve size, pressure class, material (WCB, CF8, CF8M), and end connection.
Q: What testing is performed on the valves?
Valves are tested to API 598, which includes a shell test for body integrity and a seat test to verify tight shutoff against reverse flow.
Q: Are API 602 forged valves different from API 6D cast valves?
Yes. API 602 covers small-bore forged steel valves (typically NPS 1/2 to 2) for high-pressure applications. API 6D covers larger cast or forged steel valves for pipeline service.
Q: Can the seat be repaired or replaced?
For carbon steel valves with renewable seats (typically NPS 8 and smaller), the seat can be replaced. For larger sizes or integral seats, the seat is welded and must be re-machined or the valve replaced.
To confirm the correct check valve model and configuration for your system, provide the line size, pressure class, flow medium, and installation orientation. Our engineering team will verify the selection.
For more information on API check valves, contact HYRIG: info@hyrig.com