API RF vs RTJ Flange Face | Selection & Interchangeability

2026-11-16 18:26

API RF vs RTJ Flange Face

HYRIG supplies API flanges with RF and RTJ facings. This guide explains the sealing mechanisms, pressure class boundaries, and physical differences between Raised Face (RF) and Ring Type Joint (RTJ) flanges to assist with specification.

Key Facts

  • RF (Raised Face): Standard for ASME B16.5 Class 150 and 300. Relies on a flat gasket compressed against a 1.6 mm raised surface.
  • RTJ (Ring Type Joint): Standard for API 6A wellheads and high-pressure ASME B16.5 classes (Class 900+). Relies on a metal ring gasket wedged into a groove.
  • Interchangeability: RF and RTJ are physically incompatible. They cannot mate or seal against each other.
  • Cost: RTJ flanges and ring gaskets are significantly more expensive than RF and spiral wound gaskets.

Key Specifications

FeatureRF FlangeRTJ Flange
Sealing MechanismFlat gasket compressed by bolt loadMetal ring wedged into a trapezoidal groove
Typical Pressure ClassClass 150 / 300 / 600Class 900 / 1500 / 2500, API 6A
Face Height1.6 mm (Class 150/300)No raised face; groove cut into face
Gasket TypeSpiral wound, graphite, PTFESoft iron, low carbon steel, stainless steel ring
AlignmentRelies on bolt holes and gasket IDMetal ring aligns the flanges concentrically

Dimensions

DimensionStandard
Flange DimensionsASME B16.5
RF Height1.6 mm (Class 150/300)
RTJ Groove DimensionsASME B16.20 / API 6A

Structure and Working Principle

RF (Raised Face): The sealing element is a flat gasket (often spiral wound). Bolt load compresses the gasket between the raised faces of the mating flanges. The raised face concentrates the bolt load onto a smaller area, increasing the seating stress on the gasket. This is highly effective and cost-efficient for moderate pressures.

RTJ (Ring Type Joint): The sealing element is a metal ring gasket. The flange faces are machined with a trapezoidal groove. When the bolts are tightened, the metal ring is wedged tightly between the two grooves, creating a highly reliable metal-to-metal seal. RTJ is preferred for high pressure, high temperature, and hazardous media where gasket blowout is a risk.

Cross-Reference and Replacement

When deciding between RF and RTJ, evaluate these factors:

  1. Verify Line Pressure: RF is standard up to Class 600. If the line is Class 900 or higher, RTJ is typically required.
  2. Check Existing Piping: If the existing flange is RTJ, you must replace it with an RTJ flange. An RF flange will not seal against a groove.
  3. Gasket Availability: Ensure the correct gasket type (spiral wound vs. metal ring) is available for the specified facing.

Applications

  • RF Facings: General refinery piping, utility lines, low-to-medium pressure steam and water systems.
  • RTJ Facings: High-pressure gas wells, hydrogen service, offshore platforms, and critical high-temperature lines.

Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.

Frequently Asked Questions

Q: Can I use an RF gasket on an RTJ flange?

No. An RTJ flange has a machined groove and no raised face. A flat gasket cannot seal against this groove, leading to immediate leakage.

Q: Why is RTJ more expensive?

RTJ flanges require additional machining to cut the precise trapezoidal groove. The metal ring gaskets are also significantly more expensive than spiral wound gaskets.

Q: At what pressure class should I switch from RF to RTJ?

ASME B16.5 provides RF facings up to Class 2500. However, industry practice typically shifts to RTJ starting at Class 900 for critical or hazardous service, due to the higher reliability of the metal seal.

Q: What is the typical lead time?

Standard lead time is 4 to 6 weeks depending on the flange size, class, and material.

Selection Support

To select the correct flange facing, provide the line class, operating pressure, medium, and the facing type of the mating equipment. Our engineers will confirm the specification.

Contact

For API RF or RTJ flange selection, contact HYRIG: info@hyrig.com