HYRIG can supply the API ball valve range. This FAQ page answers common technical and procurement questions about API 6D and API 608 ball valves, including design standards, testing requirements, and selection criteria.
Q: What is the difference between API 6D and API 608?
API 6D is the specification for pipeline and wellhead valves, covering larger sizes and higher pressure classes. API 608 covers general service quarter-turn valves, typically for smaller sizes and lower pressures.
Q: How does a fire-safe ball valve work?
A fire-safe valve uses a secondary metal-to-metal seal. If the primary PTFE seat melts during a fire, the metal components contact each other to maintain a seal and prevent the spread of flammable media.
Q: What standard covers fire-safe testing?
API 607 is the standard fire test for quarter-turn valves with soft seats. API 6FA is the equivalent standard for API 6D valves. Both verify performance under defined fire conditions.
Q: What is the difference between floating and trunnion ball valves?
Floating ball valves use line pressure to push the ball against the downstream seat. Trunnion ball valves use spring-loaded seats and mechanical anchors, supporting higher pressures and larger sizes with lower operating torque.
Q: Can a floating ball valve be used for DBB?
No. Floating ball valves only have a reliable downstream seal. Trunnion valves have independent bi-directional seals, which are required for Double Block and Bleed (DBB) isolation.
Q: What is the typical lead time for API ball valves?
Standard lead time is typically 4 to 6 weeks depending on size, class, and material. Fire-safe testing with third-party witness may add 1 to 2 weeks. For urgent shutdown planning, share your required date and we will confirm production priority.
Q: What materials are available for the body?
Standard body materials include ASTM A216 WCB (carbon steel) for general service, A351 CF8 (stainless steel) for mild corrosive media, and A351 CF8M for severe corrosive environments.
Q: Do the valves come with an anti-static device?
Yes. The stem and ball are designed with an anti-static device to prevent the buildup of static electricity during operation, reducing the risk of sparking in hazardous environments.
Still have questions about API ball valve specifications or standards? Share your pipeline requirements with our engineers for confirmation.
For more information on API ball valves, contact HYRIG: info@hyrig.com