HYRIG can supply the API bellows seal globe valve range. The valve is designed to BS 1873 with a metal bellows acting as the primary stem seal.
Conatct For Details
DetailReview(0)Additional

API Bellows Seal Globe Valve

HYRIG can supply the API bellows seal globe valve range. The valve is designed to BS 1873 with a metal bellows acting as the primary stem seal. This hermetic design eliminates fugitive emissions from the stem passage, making it suitable for high-temperature, vacuum, and hazardous media.

Key Facts

  • Design Standard: BS 1873
  • Pressure Class: Class 150 / Class 300
  • Size Range: NPS 1/2 to NPS 14 (DN 15 to DN 350)
  • Stem Sealing: Triple protection (Metal Bellows + Graphite Packing + Backseat)
  • Body Materials: ASTM A216 WCB, A351 CF8, A351 CF8M
  • Bellows Material: A182 F304 / A182 F316L
  • End Connection: ASME B16.5 Flanged
  • Testing Standard: API 598

Key Specifications

NPSDNClass 150 L (mm)Class 150 H (mm)Class 150 Wt (kg)Class 300 L (mm)Class 300 H (mm)Class 300 Wt (kg)
1/2"1510824141522416
3/4"2011724151782417
1"25127241620328310
1-1/4"321402801021532015
1-1/2"401652861322932220
2"502033681826739925
3"802414003531845052
4"1002924575535658488
6"150406609104444660160
8"200495698200559762259
10"250622762300622850420
12"3006988763907111085595
14"3507879906107621187876

Dimensions

DimensionStandard
Face-to-Face (L)ASTM B16.10
Flange DimensionsASME B16.5
Design ConstructionBS 1873
Inspection & TestAPI 598

Structure and Working Principle

The valve achieves sealing integrity through a triple-layer stem design:

  1. Primary Seal: A multi-ply metal bellows is welded to the stem and bonnet, creating a hermetic barrier. The bellows absorbs the axial movement of the rising stem without torsional stress, preventing premature fatigue.
  2. Secondary Seal: Flexible graphite packing sits above the bellows. If the bellows is compromised, the packing limits external leakage.
  3. Backseat: When fully open, the stem backseat engages the bonnet to provide an additional static seal.

The rising stem design provides visual position indication, allowing operators to verify open, closed, or partial-stroke status directly without instrumentation.

Cross-Reference and Replacement

When upgrading from a standard packed globe valve to a bellows seal design, four factors must be verified:

  1. Face-to-Face Dimension: Confirm the pipeline gap matches the L dimension (ASTM B16.10) listed in the specifications table.
  2. Vertical Clearance: The bellows housing increases the valve height (H dimension). Ensure sufficient overhead clearance is available for installation and maintenance.
  3. Flange Rating: Verify the mating pipe flanges match ASME B16.5 Class 150 or 300.
  4. Material Compatibility: Confirm the bellows material (A182 F304 or F316L) is compatible with the process medium and operating temperature.

Applications

  • Steam and Heat Transfer Systems: Eliminates stem packing leaks common in high-temperature steam service.
  • Vacuum Systems: The metal barrier prevents atmospheric ingress, maintaining vacuum integrity.
  • Fugitive Emission Control: Suitable for facilities requiring strict control of volatile organic compounds (VOCs) or hazardous air pollutants.

Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.

Frequently Asked Questions

Q: What is the difference between a bellows seal globe valve and a standard packed valve?

A bellows seal valve uses a metal bellows to isolate the stem from the atmosphere, eliminating fugitive emissions. A standard packed valve relies on compression packing, which requires periodic maintenance and has a measurable leak rate.

Q: How long does the metal bellows last?

Bellows cycle life depends on operating pressure, temperature, and stroke frequency. It must be evaluated on a project-specific basis; standard designs provide high fatigue resistance for continuous operation.

Q: What is the typical lead time?

Standard lead time is typically 4 to 6 weeks depending on size, material (WCB, CF8, CF8M), and order quantity.

Q: Is the valve fire-safe?

The graphite packing and metal-to-metal body gasket provide fire-resistant secondary sealing. Confirm specific fire-safe testing requirements (such as API 607) for your project specification.

Selection Support

To confirm the correct bellows material and pressure class for your system, provide the operating temperature, medium, and line size. Our engineering team will verify the configuration against BS 1873 and ASME B16.5 requirements.

Contact