This page presents verified field cases of our API 610 BB1 horizontal axial split, between-bearings, double suction pumps operating reliably in demanding continuous service. Each case demonstrates the pump's ease of maintenance, high temperature stability, and cost-effective performance.
Case 1 – Refinery Process Circulation (Middle East Refinery)
Background: A refinery needed a reliable pump for refined oil circulation (diesel/gas oil) at elevated temperature. The existing pump suffered from seal leaks and high maintenance frequency.
BB1 Pump Solution:
Flow: 850 m³/h
Head: 140 m
Temperature: 250°C
Material: Carbon steel casing, 316L impeller
Seal: API 682 Plan 23 mechanical seal
Mounting: Centerline support
Results:
Stable year-round operation with no unplanned downtime
Low failure rate – only routine annual inspection required
Axial split casing allowed quick seal replacement without removing piping
User reported 40% reduction in maintenance costs
Available references: Site photo, operating log, maintenance record.
Case 2 – Power Plant Cooling Water System (Southeast Asia)
Background: A 300 MW coal-fired power plant required a large volume circulating water pump for condenser cooling. The plant needed high efficiency and energy savings to reduce operational costs.
BB1 Pump Solution:
Flow: 2,200 m³/h
Head: 32 m
Material: Cast iron casing, stainless steel shaft
Speed: 740 rpm (low speed for large flow)
Results:
High efficiency (86%) at duty point
Energy saving of 8% compared to previous pump
Met full load power plant demand across summer and winter conditions
Double suction design eliminated axial thrust, reducing bearing temperature
Available references: Site installation photo, performance test report, efficiency comparison chart.
Case 3 – Chemical Factory Corrosive Medium (China)
Background: A chemical plant needed a pump for transferring slightly corrosive liquid (dilute acid, 70°C) with zero leakage requirement due to environmental regulations.
BB1 Pump Solution:
Flow: 400 m³/h
Head: 65 m
Temperature: 70°C
Material: 316L stainless steel (casing, impeller, shaft)
Seal: API 682 Plan 53B dual mechanical seal
Results:
Completely leak-free operation for 2+ years
No corrosion on wetted parts (316L provided excellent resistance)
Axial split design allowed easy internal inspection during annual shutdown
The plant ordered two additional BB1 pumps for other chemical transfer lines
Available references: Site photo, material certificate (EN 10204 3.1), seal plan diagram.
Case 4 – Industrial Park Centralized Water Supply (Eastern Europe)
Background: An industrial park required multiple parallel pumps for a centralized water supply system serving several factories. Stable flow and pressure across varying demand were critical.
BB1 Pump Solution:
Three BB1 pumps operating in parallel (2 duty + 1 standby)
Flow per pump: 950 m³/h
Head: 85 m (constant pressure)
Material: Cast iron casing, bronze impeller (for potable water)
Results:
Stable flow and pressure maintained across daily demand fluctuations
VFD-ready design allows speed control for energy savings
Low vibration (<2.0 mm/s) and quiet operation
Easy maintenance – pumps can be inspected one at a time without shutting down the entire water supply
Available references: Station layout drawing, site photos, pump house installation images.
What You Can Request From Us for Each Case
Site photos and installation images
Project parameter sheet (flow, head, power, material, seal type)
Actual operating data (pressure, temperature, vibration, bearing temperature)
User reference contact (with prior permission)
Why Real Project Cases Matter
Field references prove that our BB1 pumps deliver:
Stable year-round operation in refinery, power, and chemical services
High efficiency and energy savings for large flow cooling water
Corrosion resistance and leak-free performance with 316L and API 682 seals
Reliable parallel operation for industrial water supply
Get the Complete BB1 Pump Case Study Package
We can match your operating conditions to similar successful installations. Request the BB1 pump project case PDF or ask for references in your specific industry.
Email: info@hyrig.com
Please specify your industry (refinery / power plant / chemical / water supply) and we will send relevant case studies, photographs, and technical data within 24 hours. We also welcome inquiries for custom BB1 pump selection and factory direct pricing.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.