HYRIG supplies both bellows seal and packed globe valves. This guide outlines the mechanical differences between dynamic packing and static metal barriers to help specify the correct sealing method for your process conditions.
| Feature | Packed Globe Valve | Bellows Seal Globe Valve |
|---|---|---|
| Primary Seal | Dynamic compression packing | Static welded metal bellows |
| Stem Movement | Sliding through packing | Axial movement within bellows |
| Leak Path | Stem passage (dynamic) | No dynamic leak path |
| Maintenance | Periodic packing adjustment | No packing maintenance required |
| Vertical Height | Standard | Taller due to bellows housing |
| Dimension | Standard |
|---|---|
| Face-to-Face | ASTM B16.10 |
| Flange Dimensions | ASME B16.5 |
| Design Construction | BS 1873 |
A packed globe valve uses a gland follower to compress flexible packing rings against the moving stem. This creates a dynamic seal, but thermal expansion and friction eventually cause the packing to wear, leading to measurable leaks.
A bellows seal globe valve replaces the dynamic packing with a multi-ply metal bellows. The bellows is welded to both the stem and the bonnet, creating a static, hermetic barrier. The rising stem moves axially within the bellows, meaning the process media never contacts the atmosphere. A secondary graphite packing is often installed above the bellows as a backup, but it does not perform the primary sealing function.
Upgrading from a packed valve to a bellows seal design requires checking:
Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.
Q: Can a packed valve be converted to a bellows seal valve?
No. The bonnet, stem, and body of a bellows valve are specifically designed to house the metal bellows assembly. A complete valve replacement is required.
Q: Which design requires more maintenance?
Packed valves require periodic gland tightening and packing replacement due to wear. Bellows seal valves have no dynamic packing wear, significantly reducing routine maintenance.
Q: Are bellows valves suitable for high cycling applications?
Bellows valves are suitable for high cycling, but the cycle life depends on the pressure, temperature, and bellows material. For extreme high-cycle applications, verify the fatigue life with the manufacturer.
Q: What is the typical lead time?
Standard lead time for either design is typically 4 to 6 weeks depending on size and material.
To determine if a bellows seal design is required for your system, provide the operating temperature, pressure, and medium. Our engineers will help evaluate the emission risks and lifecycle costs.
For help selecting between bellows seal and packed globe valves, contact HYRIG: info@hyrig.com