A demineralized water pump (also called DM water pump or deionized water pump) handles high purity water with very low conductivity and no dissolved solids. Demineralized water is corrosive to carbon steel (it strips oxides) and can cause leaching of ions from unsuitable materials, contaminating the water. Therefore, stainless steel (typically 304, 316, or 316L) is required for all wetted parts. Our API 610 OH2 centrifugal pump is specifically engineered for reliable, contamination‑free demineralized water service. This design fully complies with API 610 11th/12th edition (ISO 13709) .
Structure match check: API 610 OH2 is defined as a horizontal, single‑stage, overhung pump with foot‑mounted casing and back pull‑out design. This matches demineralized water service requirements because:
OH2 provides easy maintenance – back pull‑out for seal, impeller, bearing inspection without disturbing piping – critical for continuous boiler feed or process water supply.
All wetted parts can be manufactured from 316SS to prevent corrosion and product contamination.
Low NPSH designs (inducer or high‑suction specific speed impeller) are available for deaerator or tank suction with limited headroom.
High efficiency reduces energy cost for 24/7 pump operation.
Why API 610 OH2 for demineralized water duty?
Purity preservation – 316SS or 316L for all wetted parts (casing, impeller, shaft, wear rings, hardware). No cast iron, no rubber that can leach. Gaskets: PTFE or EPDM (low extractables). Mechanical seal faces: SiC vs. carbon (silicon carbide recommended for long life in clean water).
Corrosion resistance – Demineralized water is aggressive to carbon steel. Stainless steel provides passive oxide layer. For high temperature demineralized water (boiler feed), 316SS is standard; for higher resistivity, 304SS also acceptable.
Low NPSH – Deaerators or storage tanks often provide limited NPSHa (2-4 m). Optional inducer reduces NPSHr below 1 m, preventing cavitation and noise.
High efficiency – Demineralized water pumps often run continuously (e.g., boiler feed, reverse osmosis feed). CFD optimized hydraulics achieve up to 85% efficiency, saving significant energy.
Wide hydraulic range – Flow 5 to 1500 m³/h, head up to 250 m, covering most demin water duties from transfer to high pressure boiler feed (though higher pressure usually requires multistage BB pumps, but OH2 is suitable for lower to medium pressures).
Key design features for demineralized water service
Materials (wetted) – Casing: 316SS (CF8M / CF3M). Impeller: 316SS or 17-4PH. Shaft: 316SS if non‑wetted, or 17-4PH for strength. Wear rings: 17-4PH (optional, can be omitted to eliminate crevices). Gaskets: PTFE or EPDM. Fasteners: 316SS.
Surface finish – For higher purity applications (e.g., pharmaceutical), electropolished wetted surfaces available.
Low NPSH – Inducer option recommended when NPSHa is below 3 m. For very low NPSH (e.g., from storage tank with lift), consult for special design.
Sealing – Single mechanical seal with Plan 11 (internal recirculation) from discharge is standard for demin water. For higher purity or to prevent any product loss, Plan 52 (tandem seal with unpressurized buffer) or Plan 53A (double seal with raised barrier) available. Seal faces: SiC vs. carbon (adequate) or SiC vs. SiC (for longer life).
Bearing housing – Oil lubricated (pure oil mist optional). For continuous operation, bearing temperature monitoring recommended.
Drain – Full capacity drain port to completely empty casing without leaving stagnant water (prevents bacterial growth in some applications).
Vent – High point vent to remove air during filling.
Typical performance range
| Parameter | Value |
|---|---|
| Flow rate | 5 – 1500 m³/h |
| Head | Up to 250 m |
| Temperature | Up to 120°C (higher with special design) |
| Pressure rating | Up to 25 bar |
| NPSHr (with inducer) | As low as 0.5 m |
| Speeds | 1450 / 2900 / 3600 rpm |
| Efficiency | Up to 85% |
Typical applications
Boiler feed water (low to medium pressure, as part of pre‑boiler circuit).
Reverse osmosis feed pumps (after pretreatment, before high pressure pump).
Demineralized water transfer from storage to process units (refinery, power, chemical, pharmaceutical).
Rinsing and washing lines (electronics, semiconductor, pharmaceutical).
Make‑up water for cooling loops (closed systems).
Laboratory and pilot plant pure water circulation.
Why choose our API 610 OH2 demineralized water pump?
Full API 610 compliance – Performance test, NPSH test (inducer), 4‑hour mechanical run test.
Contamination‑free – 316SS wetted parts, no cast iron, no rubber. Clean internal finish.
High efficiency – Energy savings over 10+ year continuous operation.
Low NPSH – Inducer prevents cavitation from deaerators or storage tanks.
Short lead time – Standard 316SS pumps available ex‑stock (2‑4 weeks).
Global spare parts support – 316SS casings, impellers, shafts, seal cartridges, bearings shipped worldwide.
Quality assurance
ISO 9001:2015 certified.
API 610 mechanical run test with vibration and bearing temperature monitoring.
Hydrostatic test of casing.
Material traceability EN 10204 3.1 / 3.2.
PMI (positive material identification) for 316SS components.
NDE – MT, PT optional for stainless steel.
How to specify your demineralized water pump
Please provide: flow (m³/h), head (m), operating temperature (°C), NPSHa (m), water conductivity or purity requirement (e.g., <0.1 µS/cm, pharmaceutical grade), installation (continuous or intermittent), and required material (standard 316SS, or higher finish). We will recommend inducer (yes/no), impeller trim, seal plan (11/52/53A), and driver details.
Contact us
For a quotation or technical discussion on demineralized water pumps (API 610 OH2) :
info@hyrig.com
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.