API 610 desulfurization rich liquid pump for transferring H₂S and CO₂‑loaded rich amine from absorber to regenerator. OH2 single-stage, BB3 high-head, VS4 vertical sump. 316L stainless steel (S-8) wetted parts. API 682 Plan 53B dual pressurized seals for zero H₂S emissions. Flows 10–1500 m³/h, heads 20–1500 m. 20-year design life, 3-year continuous run.

Conatct For Details
DetailReview(0)Additional

Product Overview

The Desulfurization Rich Liquid Pump is a specialized centrifugal pump designed to transfer “rich” solvent – the H₂S and CO₂‑loaded amine solution – from the bottom of the absorber (contactor) to the regenerator (stripper) in refinery hydrodesulfurization (HDS), natural gas sweetening, Claus tail gas treatment, and carbon capture (CCUS) processes. This rich liquid is highly corrosive, contains toxic hydrogen sulfide, and may be at elevated temperatures.

To ensure safe, emissions‑free, and reliable operation under these severe conditions, the pump is manufactured and certified to API 610 11th/12th edition (ISO 13709) standards – guaranteeing a 20‑year design life and a minimum 3‑year uninterrupted service.

Pump Configurations for Desulfurization Rich Liquid

Pump TypeConfigurationBest Rich Liquid Duty
OH2 (Preferred)Overhung, centreline‑mounted, single‑stageStandard rich amine transfer from absorber to regenerator (heads ≤150 m, flows to 600 m³/h)
BB3Axially split, multistage, between bearingsHigh‑head rich liquid (>150 m) when regenerator is elevated or absorber pressure is very high
VS4Vertical suspended sump / can typeSump or pit collection of rich liquid drains; low NPSHa installations

Key Technical Specifications

ParameterOH2BB3VS4
Flow range10 – 600 m³/h50 – 1500 m³/h10 – 750 m³/h
Head range20 – 260 m (typical ≤150 m)100 – 1500 m15 – 280 m
Pressure ratingUp to 64 barUp to 150 barUp to 40 bar
Temperature–45 to +200°C–45 to +200°C–46 to +260°C
Speed1,450 / 2,950 rpm1,450 / 2,950 rpm1,450 / 2,950 rpm

Materials – API 610 Table H

Rich amine (MDEA, MEA, DEA loaded with H₂S, CO₂, and heat‑stable salts) is highly corrosive. 316L stainless steel (API 610 Class S‑8) is the minimum requirement. Carbon steel (C‑6) must not be used.

ComponentMaterial (Standard)Upgrade Option
Casing316L SS (CF3M)Duplex (D‑1/D‑2), Super Duplex (U‑8)
Impeller316L SSDuplex, Super Duplex, 17‑4 PH
Shaft316 SS or 4140 with coating17‑4 PH, Duplex SS
Wear rings316L SS + Stellite hard‑facingTungsten carbide
Gaskets / O‑ringsSpiral wound (graphite) / FKMAflas for higher temperature

For rich amine containing H₂S partial pressure above NACE limits, NACE MR0175 / ISO 15156 certification is required.

Mechanical Seals – API 682 Compliance

Because the fluid contains toxic H₂S, fugitive emissions must be eliminated. Dual pressurized seals (API 682 Arrangement 3) with Plan 53B (bladder accumulator) are mandatory.

Seal ArrangementAPI 682 PlanApplication
Dual pressurised (Arr. 3)Plan 53BStandard for all desulfurization rich liquid pumps – zero emissions, barrier fluid pressure > process
Tandem seal (Arr. 2)Plan 52Not recommended for H₂S service
Single seal (Arr. 1)Plan 11 / 21Not permitted – H₂S leakage risk

Plan 53B provides a barrier fluid pressurised above process pressure using a bladder accumulator, preventing any amine or H₂S from leaking to atmosphere. It includes a reservoir with level indicator and low‑pressure alarm. Seal faces: silicon carbide (SiC) / SiC. Elastomers: FKM (Viton) for up to 120°C; Aflas for higher temperatures.

NPSH Considerations

The rich liquid pump typically takes suction from the bottom of an absorber operating at moderate to high pressure (5–20 barg). NPSHa is generally adequate, but dissolved gases (H₂S, CO₂, methane) can flash if suction pressure drops. Ensure no pressure loss between the absorber nozzle and pump suction flange. For low‑pressure absorbers, provide an inducer on the first‑stage impeller.

Minimum Flow Protection

Because the rich liquid flow varies with gas throughput, the pump must be protected from operation below Minimum Continuous Stable Flow (MCSF). An automatic recirculation valve (ARC) or a continuous bypass line with orifice returns minimum flow to the suction source (absorber or surge drum). This is especially critical for BB3 multistage pumps.

Applications for Desulfurization Rich Liquid Pump

IndustryProcessRich LiquidPump Configuration
Refinery HDSHydrodesulfurizationRich MDEA / DEA (H₂S + CO₂)OH2 (standard)
Natural gas sweeteningAmine treatingRich MDEA / MEAOH2 or BB3 (tall regenerator)
Claus tail gas treatmentTGTURich MDEAOH2
CCUSCarbon captureRich MEAOH2 (larger flows)
Syngas purificationAmmonia / methanolRich MDEAOH2

API 610 Compliance Highlights

  • Design life: 20 years minimum

  • Continuous operation: Minimum 3 years uninterrupted service

  • Bearing life: L10 ≥25,000 hours

  • Critical speed: ≥120% of maximum operating speed

  • Centreline mounting (OH2/BB3): Thermal stability for hot rich liquid

  • Hydrostatic test: 1.5x design pressure

  • Performance test: Water per API 610 Grade 1 or 2

  • Material certification: EN 10204 3.1 full traceability

  • NACE MR0175 / ISO 15156 available for sour service

Why Choose Our Desulfurization Rich Liquid Pump?

  • Full API 610 compliance (OH2 / BB3 / VS4) – 11th/12th edition ISO 13709, 20‑year life

  • 316L stainless steel (S‑8) as standard – proven resistance to H₂S and CO₂ corrosion

  • API 682 Plan 53B dual pressurised seals – zero emissions, mandatory for H₂S‑laden rich amine

  • Broad hydraulic coverage – flows 10–1500 m³/h, heads 20–1500 m

  • Low NPSH designs – inducer option for low‑pressure absorbers

  • Centreline mounting – handles elevated temperatures

  • Easy maintenance – back pull‑out (OH2), axial split (BB3), vertical withdrawable (VS4)

  • Minimum flow protection – ARC or bypass integrated

  • NACE MR0175 / ISO 15156 compliant options – for high H₂S partial pressure

  • Field proven – thousands of units in refineries and gas plants worldwide

Recommended Spare Parts (Per Pump)

ComponentRecommended Quantity
Mechanical seal cartridge (API 682 Plan 53B ready)1 set
Bearing set (radial + thrust)1 set
Wear ring set (casing + impeller)1 set
Gasket / O‑ring kit (full set)1 set
Inducer (if fitted)1 set

Get a Quote or Engineering Support

For selection of the correct Desulfurization Rich Liquid Pump for your refinery or gas plant – including rich amine composition, H₂S partial pressure, flow and head calculations, NACE MR0175 certification, API 682 seal plan (Plan 53B), and complete API 610 data sheet – please contact our engineering team.

Email: info@hyrig.com

Our engineers support refinery HDS, gas sweetening, and carbon capture projects worldwide with reliable, emissions‑compliant API 610 desulfurization rich liquid pumps – safe transfer of H₂S‑laden rich amine from absorber to regenerator.


Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit