HYRIG can supply DIN 3840 swing check valves in F1, F2, and F6 face-to-face series. This guide explains which PN rating and size uses which series, and why DN and PN alone are not enough to specify a replacement.
| DN | PN16 L (mm) | PN25 L (mm) | PN40 F1 L (mm) | PN40 F2 L (mm) |
|---|---|---|---|---|
| 50 | 200 (F6) | 200 (F6) | 230 | 300 |
| 100 | 300 (F6) | 300 (F6) | 350 | 430 |
| 200 | 500 (F6) | 500 (F6) | 600 | 650 |
| 300 | 700 (F6) | 700 (F6) | 850 | 900 |
Data source: Technical data table.
| Series | Typical PN | Typical DN Range |
|---|---|---|
| F1 | PN16 / PN40 | DN15–DN40 (PN16); DN15–DN300 (PN40) |
| F2 | PN25 / PN40 | DN40–DN900 |
| F6 | PN16 / PN25 | DN50–DN900 (PN16); DN40–DN900 (PN25) |
The face-to-face series defines the physical length of the valve body. It exists because the same nominal size and pressure rating can be manufactured to different lengths for different piping systems or installation practices. F1 is the shortest series and is common in small PN16 and some PN40 sizes. F2 is longer and appears at higher pressure ratings and larger sizes. F6 is the standard series for the mainstream PN16 and PN25 range.
The practical consequence is that DN and PN do not uniquely define a swing check valve. Two valves with the same DN100 and PN40 rating can have different face-to-face lengths if one is F1 and the other is F2. If the replacement valve is longer than the existing gap, the flanges will not meet; if it is shorter, the line may need a spacer or spool piece.
When replacing a DIN swing check valve:
Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.
Q: What is the difference between DIN 3202 F1 and F2?
F1 is the shorter series for PN16 and some PN40 sizes; F2 is longer and used for PN25/40 at larger sizes. They are not dimensionally interchangeable.
Q: Can I use a PN40 valve to replace a PN16 valve with the same DN?
Not without checking the face-to-face series. A PN40 F2 valve is longer than a PN16 F6 valve of the same DN and will not fit the same piping gap.
Q: Which series is used for PN16?
PN16 uses F1 for DN15–DN40 and F6 for DN50–DN900.
Q: What is the typical lead time?
Standard lead time is 4–6 weeks depending on size, PN rating, and material.
To confirm the correct face-to-face series for your replacement, provide the existing gap measurement, DN, PN rating, and flange drilling. Our engineers will match the valve to the DIN 3202 series.
For DIN 3202 F1/F2/F6 selection support, contact HYRIG: info@hyrig.com