HYRIG can supply DIN 3840 swing check valves in F1, F2, and F6 face-to-face series. This guide explains which PN rating and size uses which series, and why DN and PN alone are not enough to specify a replacement.

Key Facts

  • F1: Short face-to-face series. Used for PN16 small sizes (DN15–DN40) and some PN40 sizes (DN15–DN300).
  • F2: Longer face-to-face series. Used for PN25 and PN40 at larger sizes (DN40–DN900).
  • F6: Standard face-to-face series for PN16 DN50–DN900 and PN25 DN40–DN900.
  • Interchangeability: F1, F2, and F6 are not dimensionally interchangeable. A PN40 F2 valve will not fit a piping gap designed for a PN16 F6 valve of the same DN.

Key Specifications

DNPN16 L (mm)PN25 L (mm)PN40 F1 L (mm)PN40 F2 L (mm)
50200 (F6)200 (F6)230300
100300 (F6)300 (F6)350430
200500 (F6)500 (F6)600650
300700 (F6)700 (F6)850900

Data source: Technical data table.

Dimensions

SeriesTypical PNTypical DN Range
F1PN16 / PN40DN15–DN40 (PN16); DN15–DN300 (PN40)
F2PN25 / PN40DN40–DN900
F6PN16 / PN25DN50–DN900 (PN16); DN40–DN900 (PN25)

Structure and Working Principle

The face-to-face series defines the physical length of the valve body. It exists because the same nominal size and pressure rating can be manufactured to different lengths for different piping systems or installation practices. F1 is the shortest series and is common in small PN16 and some PN40 sizes. F2 is longer and appears at higher pressure ratings and larger sizes. F6 is the standard series for the mainstream PN16 and PN25 range.

The practical consequence is that DN and PN do not uniquely define a swing check valve. Two valves with the same DN100 and PN40 rating can have different face-to-face lengths if one is F1 and the other is F2. If the replacement valve is longer than the existing gap, the flanges will not meet; if it is shorter, the line may need a spacer or spool piece.

Cross-Reference and Replacement

When replacing a DIN swing check valve:

  1. Measure the existing gap: Do not rely on the DN and PN alone. Measure the face-to-face length and compare it to the F1/F2/F6 table.
  2. Check the flange drilling: DIN 2543/2544/2545 and EN 1092-1 differ from ASME B16.5. Confirm the mating flange standard.
  3. Do not substitute across series: A PN40 F2 valve cannot replace a PN16 F6 valve in the same gap, even if the bore and flange drilling are compatible.

Applications

  • F1: Small PN16 lines, compact skids, and some PN40 small-bore installations.
  • F2: PN40 and PN25 lines at larger sizes, where the longer body accommodates the higher-pressure disc and seat.
  • F6: Mainstream PN16 and PN25 plant piping, cooling water, and utility headers.

Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.

Frequently Asked Questions

Q: What is the difference between DIN 3202 F1 and F2?

F1 is the shorter series for PN16 and some PN40 sizes; F2 is longer and used for PN25/40 at larger sizes. They are not dimensionally interchangeable.

Q: Can I use a PN40 valve to replace a PN16 valve with the same DN?

Not without checking the face-to-face series. A PN40 F2 valve is longer than a PN16 F6 valve of the same DN and will not fit the same piping gap.

Q: Which series is used for PN16?

PN16 uses F1 for DN15–DN40 and F6 for DN50–DN900.

Q: What is the typical lead time?

Standard lead time is 4–6 weeks depending on size, PN rating, and material.