HYRIG can supply the DIN 3840 swing check valve range. The DIN swing check valve is a flanged non-return valve with a hinged disc, designed to BS EN 1868 and DIN 3840, with face-to-face dimensions
Conatct For Details
DetailReview(0)Additional

DIN 3840 Swing Check Valve

HYRIG can supply the DIN 3840 swing check valve range. The DIN swing check valve is a flanged non-return valve with a hinged disc, designed to BS EN 1868 and DIN 3840, with face-to-face dimensions per DIN 3202 F1/F2/F6 and EN 558-1. It is available in PN16, PN25, PN40, PN63 and PN100.

Key Facts

  • Design standard: DIN 3840, BS EN 1868
  • Pressure rating: PN16 / PN25 / PN40 / PN63 / PN100
  • Size range: DN40–DN900 (PN16/25/40); DN15–DN400 (PN40 per DIN 3202 F1)
  • Face-to-face: DIN 3202 F1 / F2 / F6, EN 558-1
  • Flange drilling: DIN 2543 / DIN 2544 / DIN 2545 / EN 1092-1
  • Testing: DIN 3230, EN 12266-1, API 598 (optional)
  • Body materials: DIN 17245 GS-C25, A216 WCB, CF8, CF8M

Key Specifications

DNPN16 L (F1/F6)PN25 L (F6)PN40 L (F1)PN40 L (F2)
40180180200260
50200200230300
80260260310380
100300300350430
150400400480550
200500500600650
300700700850900

Data source: Technical data table. PN16 uses DIN 3202 F1 for DN15–DN40 and F6 for DN50–DN900; PN25 uses F6; PN40 uses F1 or F2 depending on size.

To verify the correct face-to-face series for your pressure rating, read the DIN 3202 F1 vs F2 vs F6 comparison. To compare swing check against dual-plate check on water hammer and dirty service, read the DIN swing check vs API 594 dual plate guide.

Dimensions

DimensionStandard
Face-to-face (PN16)DIN 3202 F1 (DN15–40), F6 (DN50–900)
Face-to-face (PN25)DIN 3202 F6
Face-to-face (PN40)DIN 3202 F1 or F2
Flange drillingDIN 2543 (PN16), DIN 2545 (PN40), EN 1092-1
TestingDIN 3230, EN 12266-1

Structure and Working Principle

The valve uses a full-bore hinged disc that swings open under forward flow and returns to the seat when flow stops or reverses. Because the disc clears the bore in the open position, pressure drop is low compared with a lift or piston check. The bolted bonnet allows access to the disc and seat for inspection without removing the body from the line.

The critical procurement variable is the face-to-face series, not just the DN and PN. DIN 3202 defines multiple series (F1, F2, F6) with different lengths for the same nominal size and pressure rating. A valve with the correct bore and flange drilling but the wrong series will not fit the piping gap. PN16 generally uses F1 for small sizes and F6 for larger sizes; PN40 can use F1 or F2 depending on the size. Always confirm the series against the existing piping gap before ordering.

Cross-Reference and Replacement

Replacing a DIN swing check valve? Verify these before ordering:

  1. Face-to-face series: Measure the existing gap and match it to the DIN 3202 series (F1, F2, or F6). DN and PN alone do not define the length.
  2. Flange drilling: DIN 2543/2544/2545 and EN 1092-1 are not interchangeable with ASME B16.5. Confirm the mating flange standard.
  3. Installation orientation: Standard swing checks are for horizontal or vertical upward flow. Confirm whether the existing valve is installed vertically and whether a spring-assisted or damped design is required.
  4. Pressure rating vs series: A PN40 valve does not share the same face-to-face length as a PN16 valve of the same DN. Do not substitute across pressure ratings without checking the piping gap.

Applications

  • Pump discharge lines: Low pressure drop and full-bore flow suit large water pumps.
  • Cooling water headers: Simple, spring-free construction tolerates dirty water better than a dual-plate check.
  • Steam condensate returns: Metal-seated swing checks handle moderate temperatures where soft seats are unsuitable.
  • European-standard plant piping: Face-to-face and flange drilling per DIN/EN allow direct replacement in skids built to European standards.

Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation. Verify the DIN 3202 face-to-face series against the existing piping gap before ordering.

Frequently Asked Questions

Q: What is the difference between DIN 3202 F1 and F2?

F1 is the short face-to-face series used for PN16 and some PN40 sizes; F2 is longer and used for PN25/40 at larger sizes. They are not dimensionally interchangeable.

Q: Does a DIN swing check valve have the same face-to-face as an ANSI check valve?

No. DIN 3202 and ASME B16.10 define different lengths. A DIN F1 valve is often shorter than the ANSI equivalent at the same DN.

Q: Can a DIN swing check valve be installed vertically?

Some configurations accept vertical upward flow, but the disc must close by gravity. Confirm the orientation and minimum flow with the manufacturer before ordering.

Q: What is the typical lead time?

Standard lead time is 4–6 weeks depending on size, PN rating, material, and documentation.

Selection Support

To confirm the correct face-to-face series, flange drilling, and disc material for your line, provide the DN, PN rating, existing piping gap, medium, and installation orientation. Our engineering team will verify the DIN 3202 series and EN 558-1 dimensions.

Contact

For DIN 3840 swing check valve selection, contact HYRIG: info@hyrig.com