HYRIG can supply BS EN 1092-1 steel pipe flanges. The EN 1092-1 flange is the European-standard flanged connection, designated by DN and PN. It is available in PN16, PN25 and PN40, in Type 11 (weld neck) and Type 01 (plate flange) designs, with Form A (flat face) or Form B (raised face) facings.
| DN | PN16 D (mm) | PN16 k (mm) | PN16 b (mm) | PN16 Bolts | PN40 D (mm) | PN40 k (mm) | PN40 b (mm) | PN40 Bolts |
|---|---|---|---|---|---|---|---|---|
| 50 | – | – | – | – | 195 | 145 | 30 | 4 × M20 |
| 100 | 220 | 180 | 20 | 8 × M16 | 235 | 190 | 24 | 8 × M20 |
| 150 | 285 | 240 | 22 | 8 × M20 | 300 | 250 | 28 | 8 × M24 |
| 200 | 340 | 295 | 24 | 12 × M20 | 375 | 320 | 34 | 12 × M27 |
Data source: Technical data table. PN16 DN≤50 conforms to DIN 2545 (PN40 dimensions) per the standard note.
| Dimension | Standard |
|---|---|
| Flange OD (D) | EN 1092-1 |
| Bolt circle (k) | EN 1092-1 |
| Flange thickness (b) | EN 1092-1 |
| Raised face (d4, f) | EN 1092-1 Form B |
| Flange neck (d3, S0, S1) | EN 1092-1 Type 11 |
| Bolt hole (d2) | Metric, EN 1092-1 |
EN 1092-1 defines flanges by DN and PN, not by NPS and Class. The PN number is a nominal pressure reference, not the allowable pressure at temperature. The actual pressure-temperature rating must be read from the EN 1092-1 material-group tables: a PN16 carbon steel flange is rated at about 13.3 bar at 200 C, not 16 bar.
The Type 11 weld-neck flange has a tapered hub that transfers stress from the flange ring to the pipe wall. It is used for high-pressure, high-temperature, and cyclic service. The Type 01 plate flange is a flat plate with a bore, welded to the pipe by fillet welds. It is limited to lower pressure ratings and less severe service.
The face form determines the gasket and bolting logic. Form A is a full flat face and requires a full-face gasket. Form B is a raised face and is used with spiral wound or soft gaskets confined within the raised-face diameter. Omitting the face form in an RFQ is a common cause of gasket sealing failure.
Replacing an ASME B16.5 flange with an EN 1092-1 flange requires verification of four factors:
Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation. The PN rating is a nominal reference; verify the allowable pressure at operating temperature from the EN 1092-1 material-group table.
Q: Can a PN 16 flange replace a Class 150 flange?
No. The bolt circle, bolt thread, and pressure rating basis differ; they cannot be bolted together.
Q: What does PN 16 actually mean at 200 C?
A PN 16 carbon steel flange is rated at about 13.3 bar at 200 C; the PN number is not the allowable pressure at temperature.
Q: What is the difference between Type 11 and Type 01?
Type 11 is a weld-neck flange with a tapered hub for high-pressure and cyclic service. Type 01 is a plate flange for lower-pressure, less severe service.
Q: What is the difference between Form A and Form B?
Form A is a flat face requiring a full-face gasket. Form B is a raised face used with spiral wound or confined gaskets.
Q: What is the typical lead time?
Standard lead time is 4-6 weeks depending on size, PN rating, material, and documentation.
To confirm the correct flange type, face form, and bolting for your line, provide the DN, PN rating, existing piping standard, face form, and material requirement. Our engineering team will verify the EN 1092-1 dimensions and pressure-temperature rating.
For BS EN 1092-1 flange selection, contact HYRIG: info@hyrig.com