HYRIG can supply the DIN globe valve range. The DIN globe valve is a rising-stem throttling valve designed to BS 1873 and DIN 3230, with OS&Y design and metal-to-metal seating.
Conatct For Details
DetailReview(0)Additional

DIN Globe Valve

HYRIG can supply the DIN globe valve range. The DIN globe valve is a rising-stem throttling valve designed to BS 1873 and DIN 3230, with OS&Y design and metal-to-metal seating. It is available in PN16 to PN100, with face-to-face dimensions per DIN 3202 F1 or F2.

Key Facts

  • Design standard: BS 1873, DIN 3230
  • Pressure rating: PN16 / PN25 / PN40 / PN63 / PN100
  • Size range: DN15–DN350 (PN16–PN40), DN15–DN300 (PN63–PN100)
  • Stem design: OS&Y (outside screw and yoke), rising stem
  • Seat type: Metal-to-metal (Stellite or Cr13 overlay)
  • Face-to-face: DIN 3202 F1 (PN16/25/40), F2 (PN63/PN100)
  • Flange drilling: DIN 2543–2548 / EN 1092-1

Key Specifications

DNPN16 L (F1)PN40 L (F1)PN100 L (F2)
50230230300
100350350430
150480480550
200600600650
300850850900

Data source: Technical data table. Full DN15–DN350 table available on request.

Dimensions

DimensionStandard
Face-to-face (PN16–PN40)DIN 3202 F1
Face-to-face (PN63–PN100)DIN 3202 F2
Flange drillingDIN 2543–2548 / EN 1092-1

Structure and Working Principle

The valve uses a plug-type disc that moves linearly along the stem. As the valve opens, the disc lifts off the seat, gradually increasing the flow area. This design provides precise throttling control, making it suitable for frequent operation and flow regulation.

The OS&Y (outside screw and yoke) design places the stem threads outside the valve body, exposed to the atmosphere. This prevents the threads from contacting the process fluid, reducing corrosion and galling. The rising stem provides a clear visual indication of the valve position.

Important procurement note: DIN 3202 defines different face-to-face lengths for different pressure ratings. PN16–PN40 uses F1 (short pattern); PN63–PN100 uses F2 (long pattern). DN and PN alone do not define the length, so the face-to-face series must be stated explicitly in the RFQ.

Cross-Reference and Replacement

Replacing a DIN globe valve requires verification of four factors:

  1. Face-to-face series: Confirm whether the existing valve uses F1 or F2. DN and PN alone are not enough.
  2. Stem configuration: Confirm OS&Y (rising stem) vs NRS (non-rising stem). OS&Y requires headroom.
  3. Seat material: Standard is Cr13 or Stellite. Confirm the trim number (Trim 1, 8, or 5).
  4. Pressure rating: A PN40 valve does not share the same face-to-face length as a PN63 valve. Do not substitute across pressure ratings without checking the piping gap.

Applications

  • Throttling and flow control: The plug-type disc provides precise regulation in process lines.
  • High-temperature steam: Metal-to-metal seating and OS&Y design suit steam service.
  • Boiler feedwater: Reliable isolation and regulation for high-pressure water.
  • Chemical processing: Hard-faced trim handles corrosive and erosive media.

Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation. Verify the DIN 3202 face-to-face series against the existing piping gap before ordering.

Frequently Asked Questions

Q: What is the difference between a globe valve and a gate valve?

A globe valve is designed for throttling and frequent operation, while a gate valve is for on/off isolation with minimal pressure drop.

Q: Does DN and PN uniquely define the face-to-face length?

No. DIN 3202 defines multiple series (F1, F2). PN16–PN40 generally uses F1; PN63–PN100 uses F2. Always specify the series.

Q: What is the purpose of an OS&Y design?

An OS&Y (outside screw and yoke) design keeps the stem threads outside the process fluid, preventing corrosion and providing clear visual indication of valve position.

Q: What is the typical lead time?

Standard lead time is 4-6 weeks depending on size, PN rating, material, and actuation requirements.

Selection Support

To confirm the correct face-to-face series and trim for your line, provide the DN, PN rating, existing piping gap, medium, and temperature. Our engineering team will verify the DIN 3202 series and valve configuration.

Contact

For DIN globe valve selection, contact HYRIG: info@hyrig.com

Related Pages

Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit