HYRIG can supply the DIN globe valve range. The DIN globe valve is a rising-stem throttling valve designed to BS 1873 and DIN 3230, with OS&Y design and metal-to-metal seating. It is available in PN16 to PN100, with face-to-face dimensions per DIN 3202 F1 or F2.
| DN | PN16 L (F1) | PN40 L (F1) | PN100 L (F2) |
|---|---|---|---|
| 50 | 230 | 230 | 300 |
| 100 | 350 | 350 | 430 |
| 150 | 480 | 480 | 550 |
| 200 | 600 | 600 | 650 |
| 300 | 850 | 850 | 900 |
Data source: Technical data table. Full DN15–DN350 table available on request.
| Dimension | Standard |
|---|---|
| Face-to-face (PN16–PN40) | DIN 3202 F1 |
| Face-to-face (PN63–PN100) | DIN 3202 F2 |
| Flange drilling | DIN 2543–2548 / EN 1092-1 |
The valve uses a plug-type disc that moves linearly along the stem. As the valve opens, the disc lifts off the seat, gradually increasing the flow area. This design provides precise throttling control, making it suitable for frequent operation and flow regulation.
The OS&Y (outside screw and yoke) design places the stem threads outside the valve body, exposed to the atmosphere. This prevents the threads from contacting the process fluid, reducing corrosion and galling. The rising stem provides a clear visual indication of the valve position.
Important procurement note: DIN 3202 defines different face-to-face lengths for different pressure ratings. PN16–PN40 uses F1 (short pattern); PN63–PN100 uses F2 (long pattern). DN and PN alone do not define the length, so the face-to-face series must be stated explicitly in the RFQ.
Replacing a DIN globe valve requires verification of four factors:
Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation. Verify the DIN 3202 face-to-face series against the existing piping gap before ordering.
Q: What is the difference between a globe valve and a gate valve?
A globe valve is designed for throttling and frequent operation, while a gate valve is for on/off isolation with minimal pressure drop.
Q: Does DN and PN uniquely define the face-to-face length?
No. DIN 3202 defines multiple series (F1, F2). PN16–PN40 generally uses F1; PN63–PN100 uses F2. Always specify the series.
Q: What is the purpose of an OS&Y design?
An OS&Y (outside screw and yoke) design keeps the stem threads outside the process fluid, preventing corrosion and providing clear visual indication of valve position.
Q: What is the typical lead time?
Standard lead time is 4-6 weeks depending on size, PN rating, material, and actuation requirements.
To confirm the correct face-to-face series and trim for your line, provide the DN, PN rating, existing piping gap, medium, and temperature. Our engineering team will verify the DIN 3202 series and valve configuration.
For DIN globe valve selection, contact HYRIG: info@hyrig.com
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.