HYRIG can supply the DIN bellows seal globe valve range. The valve uses a metal bellows as the primary stem seal, eliminating fugitive emissions from the stem passage.
Conatct For Details
DetailReview(0)Additional

DIN Bellows Seal Globe Valve

HYRIG can supply the DIN bellows seal globe valve range. The valve uses a metal bellows as the primary stem seal, eliminating fugitive emissions from the stem passage. It is designed to DIN 3356 and DIN 3202, suitable for toxic media, vacuum, and high-temperature service.

Key Facts

  • Design standard: DIN 3356, BS 1873
  • Pressure rating: PN16 / PN25 / PN40
  • Size range: DN15–DN350
  • Stem seal: Metal bellows (primary) + graphite packing (secondary)
  • Face-to-face: DIN 3202 F1
  • Flange drilling: DIN 2543–2545 / EN 1092-1

Key Specifications

DNPN16 L (F1)PN16 H (mm)PN40 L (F1)PN40 H (mm)
50230250230250
100350370350370
150480515480515
200600550600550
300850630850630

Data source: Technical data table.

Dimensions

DimensionStandard
Face-to-faceDIN 3202 F1
Flange drillingDIN 2543–2545 / EN 1092-1
InstallationVertical, handwheel up (recommended)

Structure and Working Principle

The valve uses a plug-type disc for throttling, identical to a standard globe valve. The difference is the stem seal. A multi-ply metal bellows is welded to the stem and bonnet, creating a hermetic barrier. The rising stem moves axially within the bellows, but the process media never contacts the dynamic packing area.

Above the bellows, flexible graphite packing sits as a secondary seal. If the bellows develops a fatigue crack, the packing limits external leakage until the valve can be serviced. This triple-layer design (bellows + packing + backseat) ensures zero fugitive emissions during normal operation.

Installation note: Bellows seal valves should be installed with the stem vertical (handwheel up). Horizontal or downward installation places the weight of the stem and bellows on the guiding surfaces, accelerating wear and potentially causing early bellows failure.

Cross-Reference and Replacement

When replacing a packed globe valve with a bellows seal design:

  1. Check the installation space: Bellows valves have a taller profile (H dimension) than standard globe valves. Confirm the available headroom.
  2. Verify the installation orientation: Ensure the stem can be vertical. Horizontal installation is not recommended.
  3. Check the face-to-face: Both use DIN 3202 F1, but confirm the specific DN and PN against the piping gap.
  4. Confirm the bellows material: Standard is SS304. For corrosive media, confirm if SS316 is required.

Applications

  • Toxic and hazardous media: Hermetic seal prevents leakage of chlorine, ammonia, and phosgene.
  • High-temperature steam: Metal bellows and graphite packing handle elevated temperatures.
  • Vacuum systems: The metal barrier prevents atmospheric ingress.
  • Fugitive emission control: Suitable for facilities with strict VOC or HAP regulations.

Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation. Bellows seal valves should be installed with the stem vertical (handwheel up) to ensure proper lubrication and prevent premature wear.

Frequently Asked Questions

Q: What is the difference between a bellows seal and a standard packed globe valve?

A bellows seal uses a metal barrier to isolate the stem, eliminating fugitive emissions. A standard valve relies on compression packing, which can degrade and leak over time.

Q: Can a bellows seal valve be installed horizontally?

It is not recommended. The weight of the stem and bellows can cause uneven wear. Vertical installation (handwheel up) is preferred.

Q: How do I know if the bellows has failed?

If a monitoring port is available, a pressure gauge can detect leakage. Without a port, the secondary graphite packing acts as a backup seal until inspection.

Q: What is the typical lead time?

Standard lead time is 4-6 weeks depending on size, PN rating, and bellows material.

Selection Support

To confirm the correct bellows seal valve for your line, provide the medium, operating temperature, pressure class, and available installation space. Our engineers will verify the bellows material and installation orientation.