HYRIG can supply DIN Y-strainers with mesh sizes from 5 to 300. This guide converts mesh count to micron opening, shows how open area changes with mesh, and matches the screen to downstream equipment including steam traps, control valves, pumps, and meters.

Key Facts

  • 20 mesh: approximately 356 micron at 51.8% open area.
  • 40 mesh: approximately 193 micron at 48.4% open area.
  • 100 mesh: approximately 102 micron at 35.8% open area.
  • 300 mesh: approximately 39 micron at 27.6% open area.
  • Specification rule: Specify the opening in micron, not mesh count alone, because wire diameter changes the actual opening at the same mesh.

Key Specifications

Downstream EquipmentRecommended MeshOpening (mm)
Centrifugal pumps10-200.71-1.83
Steam traps20-400.19-0.36
Control valves40-600.15-0.19
Flowmeters / instruments60-1000.10-0.15
General pipeline protection10-200.36-1.83

Dimensions

DimensionStandard
Face-to-faceDIN 3202 F1
Flange drillingDIN 2543–2551 / EN 1092-1
Screen materialASTM A182 F304

Structure and Working Principle

Mesh count alone does not define the filtration opening. At the same mesh number, a larger wire diameter reduces the open area and the actual opening. For example, the catalogue data shows that moving from 20 mesh (51.8% open area) to 300 mesh (27.6% open area) nearly halves the open area. A screen with lower open area blinds faster and produces higher clean pressure drop.

For steam service, a Dutch weave screen such as 30 x 160 is often preferred because it tolerates a higher differential pressure before rupture. For liquid service requiring 80 mesh or finer, the screen belongs in a basket strainer rather than a Y-strainer, because the Y-pocket cannot provide sufficient open area.

Cross-Reference and Replacement

When selecting a mesh for a DIN Y-strainer:

  1. Start from the downstream equipment tolerance: Identify the smallest particle the equipment can tolerate, then convert that to micron.
  2. Check the open area: A finer mesh has lower open area and blinds faster. Confirm the cleaning interval is acceptable.
  3. Match the strainer type to the mesh: For 80 mesh or finer in liquid service, use a basket strainer.

Applications

  • Steam trap protection: 20-40 mesh captures pipe scale without blinding too quickly.
  • Pump suction: 10-20 mesh protects the impeller from large debris.
  • Control valve protection: 40-60 mesh captures particles that could erode the trim.
  • Instrument protection: 60-100 mesh protects small passages in flowmeters and analyzers.

Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.

Frequently Asked Questions

Q: What mesh is 100 micron?

100 micron is approximately 150 mesh. A 100 mesh screen has an opening of about 102 micron.

Q: Is 40 mesh finer than 20 mesh?

Yes. Higher mesh number means finer screen. 40 mesh (about 193 micron) is finer than 20 mesh (about 356 micron).

Q: What mesh should I use for a steam trap?

20-40 mesh is standard for steam trap protection. Finer mesh blinds faster and may not be necessary.

Q: What is the typical lead time?

Standard lead time is 4–6 weeks depending on size, PN rating, material, and mesh requirement.

Selection Support

To select the correct mesh and screen material, provide the downstream equipment, maximum allowable particle size, medium, and cleaning interval. Our engineers will confirm the mesh and open area.

Contact

For DIN Y-strainer mesh selection, contact HYRIG: info@hyrig.com

Related Pages

Name:
Message:
Verification code:
Submit
Comment