API 610 BB2 horizontal, axially split, multistage pump for process feed duties (e.g., FCC, hydrotreating, reforming). Designed for high heads (up to 1000 m), high temperatures (up to 400°C), and continuous reliable operation. China BB2 pump manufacturer.

Conatct For Details
DetailReview(0)Additional

A feed pump in oil refineries and petrochemical plants delivers feedstock to a high‑pressure process unit – such as a fluid catalytic cracking (FCC) reactor, hydrotreating or hydrocracking reactor, catalytic reformer, or coker. These pumps operate continuously at high discharge pressures, moderate to high flow, and often at elevated temperatures. Our API 610 BB2 multistage, axially split, between‑bearings pump is specifically engineered for such demanding feed service. This design fully complies with API 610 11th/12th edition (ISO 13709) .

Structure match check: API 610 BB2 is defined as a horizontal, axially split, multistage, between‑bearings pump with centerline support for high temperature. This matches feed pump requirements because:

  • Multistage design (2 to 10+ stages) achieves the high heads required to feed pressure vessels (e.g., 200‑1000 m, up to 200 bar).

  • Axially split casing allows removal of the top half for inspection and maintenance without disconnecting suction/discharge piping – critical for high‑availability processes.

  • Centerline support accommodates thermal expansion at elevated feed temperatures (up to 400°C).

  • Between‑bearings rotor ensures stability at high speeds and under high radial loads.

  • High efficiency reduces energy cost for pumps that run 8,000+ hours/year.

Why API 610 BB2 for feed pump duty?

  • High head capability – Single‑stage pumps cannot achieve the heads required for most hydroprocessing or FCC feed. BB2 multistage provides 200‑1000 m head with safe, proven stage design.

  • High temperature – Feeds (such as vacuum gas oil, heavy naphtha, or preheated crude) often enter process at 150‑400°C. Centerline support, water‑cooled bearing housings, and high temperature metallurgy (WC6 grade) are standard.

  • Reliability – Feed pump failure means immediate process shut‑down. BB2 with heavy duty oil film bearings (or anti‑friction), stellite wear rings, and API 682 sealing ensures >3‑5 years MTBR.

  • Easy maintenance – Axially split design simplifies stage replacement, bearing inspection, and seal change without alignment loss.

  • Wide hydraulic coverage – Flow from 50 to 3000 m³/h, covering hydrotreater, FCC, reformer, and hydrocracker feed rates.

Key design features for feed pump service

  • Casing – Axially split, centerline support. Material: carbon steel (WCB) for moderate temp, WC6 (1¼Cr-½Mo) for up to 450°C. Pressure rating: ASME Class 600 to 1500 per discharge head. Impeller passages generously sized for slightly dirty feed.

  • Impellers – Closed, radial, multistage. Opposed impeller arrangement (back‑to‑back) for hydraulic thrust balance, eliminating need for balance drum. Hardened 12% chrome (CA6NM) or 17-4PH. Replaceable wear rings (Stellite or hardened 17-4PH).

  • Diffusers – Stationary vanes converting velocity to pressure, also hardened stainless steel.

  • Shaft – Through‑shaft at minimal deflection. Material: 12% chrome or 17-4PH. Shaft sleeves replaceable under seals.

  • Bearings – Tilting pad journal bearings for high speed; double‑acting Kingsbury thrust bearing. Pure oil mist lubrication standard. For high temperature, bearing housing with cooling water jacket.

  • Sealing – API 682 Plan 23 (cooled recirculation) for hot feed (most common). For volatile feeds (light naphtha, light hydrocarbons), double seals with Plan 53A. Seal faces: SiC vs. SiC. Tandem seals with Plan 52 for non‑volatile but hazardous feeds.

  • NPSH – First stage often double‑suction or with inducer to minimize NPSHr. Feed pump suction often from atmospheric storage or from preceding unit, requiring low NPSHr.

  • Materials for sour feed – NACE MR0175 compliance (e.g., LCC casing, 12% chrome impellers) for feeds containing H₂S (many hydroprocessing feeds).

Typical performance range

ParameterValue
Flow rate50 – 3000 m³/h
Head200 – 1000 m
Discharge pressureUp to 200 bar
TemperatureUp to 400°C
Speeds1500 – 6000 rpm
Stages2 – 10

Typical applications

  • FCC (fluid catalytic cracking) feed pump – preheated vacuum gas oil.

  • Hydrotreater feed pump – light gas oil, naphtha, or diesel.

  • Hydrocracker feed pump – heavy gas oil, VGO (very high pressure).

  • Catalytic reformer feed pump – naphtha to platformer.

  • Coker feed pump – vacuum residue or heavy gas oil.

  • Recycle feed pump – within the same process loop.

Why choose our API 610 BB2 feed pump?

  • Full API 610 compliance – Type BB2 verified. Performance test, NPSH test, 4‑hour mechanical run test with vibration monitoring.

  • High pressure/high temperature design – WC6 casings, centerline support, cooled bearings, Plan 23 seals.

  • Hydraulic thrust balance (opposed impellers) – eliminates balance drum wear, reduces maintenance.

  • Easy maintenance – Axially split casing allows access without pipe disturbance.

  • Short lead time – Standard sizes with WC6 casing and 12% chrome internals available 28‑32 weeks.

  • Global spare parts support – Stage pieces, impeller sets, shafts, wear rings, bearings, seal cartridges shipped worldwide.

Quality assurance

  • ISO 9001:2015 certified.

  • API 610 mechanical run test with vibration and bearing temperature monitoring.

  • Hydrostatic test of casing at 1.5× working pressure.

  • Material traceability EN 10204 3.1 (3.2 on request).

  • NDE – MT, PT, UT, RT as required.

  • Rotor dynamic analysis report.

How to specify your feed pump

Please provide: flow (m³/h), head (m), operating temperature (°C), feed liquid (e.g., VGO, naphtha, gas oil, resid), specific gravity, viscosity (cSt), NPSHa (m), H₂S content (for NACE), required discharge pressure (bar), and driver type. We will recommend number of stages, impeller orientation, seal plan (23/53A), material class (WCB/WC6), and bearing lubrication.

Contact us

For a quotation or technical discussion on feed pumps (API 610 BB2) :

info@hyrig.com