HYRIG can supply API globe valves for throttling and flow control applications. This guide explains the plug-type disc design, the resulting pressure drop, and the engineering risks of cavitation and flashing in high-pressure reduction.
| Feature | Globe Valve | Gate Valve |
|---|---|---|
| Flow Path | S-shaped | Straight-through |
| Throttling Capability | Excellent | Poor |
| Pressure Drop | Moderate to high | Very low |
| Cavitation Risk | High if pressure drop is extreme | Low |
| Dimension | Standard |
|---|---|
| Face-to-face | ASME B16.10 |
| Flanged ends | ASME B16.5 / B16.47 |
| Butt weld ends | ASME B16.25 |
The globe valve uses a plug-type disc that moves along the stem axis. As the disc lifts off the seat, the flow area increases, allowing more fluid to pass. This linear movement provides precise control over the flow rate, making the globe valve the standard choice for throttling.
However, the S-shaped flow path creates a significant pressure drop. In high-pressure reduction applications, this pressure drop can cause cavitation. When the fluid accelerates through the seat and the pressure drops below its vapor pressure, vapor bubbles form. As the fluid exits the seat and the pressure recovers, these bubbles collapse violently, causing erosion and noise. If the downstream pressure remains below the vapor pressure, flashing occurs, and the fluid stays as a gas.
When selecting a globe valve for throttling:
Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation. For throttling service with high pressure drops, verify cavitation and flashing risks with the manufacturer.
Q: Why do globe valves have a higher pressure drop?
The S-shaped flow path forces the fluid to change direction, creating turbulence and energy loss. This design is necessary for the disc to control the flow area.
Q: What is cavitation in a globe valve?
Cavitation occurs when the pressure drop causes the fluid to vaporize. As the pressure recovers downstream, the vapor bubbles collapse, causing noise, vibration, and erosion of the valve components.
Q: Can I use a globe valve for on/off service?
Yes. A globe valve provides tight shutoff. However, if the valve is fully open or fully closed for long periods without throttling, a gate valve is often more economical.
Q: What is the typical lead time?
Standard lead time is 4 to 6 weeks depending on size, class, and trim material.
To select the correct globe valve for your throttling application, provide the flow rate, upstream and downstream pressure, and fluid properties. Our engineers will evaluate the cavitation risk and recommend the appropriate trim.
For globe valve flow control selection, contact HYRIG: info@hyrig.com