Operators must read the KT20000 Casing Tong Operation & Maintenance Manual in full and pass safety and operation assessments before working.
Wear full PPE: flame-resistant coverall, impact-resistant helmet, puncture-resistant boots, non-slip gloves. No loose clothing or jewelry (risk of entanglement).
Clear role assignment: 1 main operator (controls), 1 field supervisor (safety and assistance). Single-person operation is prohibited.
Appearance & Components:
No deformation or cracks on tong body. Safety door operates smoothly and locks securely.
Jaws installed firmly. Rollers free of wear or breakage. Locating pins free of deformation or rust.
Hydraulic hoses – no damage or bulges. Fittings sealed with no oil leaks.
Torque gauge and pressure gauge display normally; pointer returns to zero with no sticking.
Hydraulic System:
Oil level between tank marks. Oil clean, no contamination or emulsification.
Hydraulic pump and motor connections secure, no looseness or aging. Grounding good.
Confirm high-pressure hose (1″) and return hose (1-1/4″) are correctly connected. Self-sealing couplers must click locked.
Auxiliary Tools:
Required: torque wrench, pipe wrench, grease, cleaning cloth, emergency tool kit.
Safety items: warning cones, safety tape, fire extinguisher (placed nearby).
Clear work area of debris and obstacles. Set safety zone within 5 m radius – no unauthorized personnel.
Check suspension and fixing:
Suspension wire rope ≥5/8″ – no broken strands or rust. Connection points secure.
Level tong using turnbuckles. Align with casing center axis (tolerance ≤2°).
Backup line (≥5/8″ wire rope) connected horizontally at 90° to rear dynamometer. Anchor point secure (e.g., rig floor anchor) with no slack.
Supervisor confirms site safety and signals operator to start.
Operator opens hydraulic system bypass valve, starts hydraulic pump motor, circulates oil for warm-up (5-10 minutes at ambient temperature; 20 minutes at -40°C to 0°C).
During warm-up, check hydraulic pressure (idle ≤200 PSI). Inspect hoses for leaks, listen for abnormal noise.
Move shift lever to neutral. Lightly push throttle control rod to test forward/reverse rotation. Confirm safety door interlock works (unit cannot start if door not locked).
Verify jaw size matches casing specification and locating pins are fully inserted.
| Step | Action | Caution |
|---|---|---|
| 1 | Position tong: Operator and supervisor align tong opening with casing joint. Slide smoothly to gripping position. Ensure jaw contacts casing without gap. | |
| 2 | Lock safety door: Close door until double lock click (or lock indicator light). Supervisor confirms locked. | |
| 3 | Insert locating pin: Insert pin into make-up hole (not break-out hole). Tap fully to secure. Prevents pin falling during operation. | |
| 4 | Shift to high gear: Move lever from neutral down to high gear (23 rpm). For fast thread engagement. | |
| 5 | Controlled torque application: ① Push throttle 1/3 stroke for slow thread engagement (avoid damage). ② After full engagement, push throttle fully until tong nearly stops (initial tightening). ③ Shift to low gear (3 rpm), apply throttle to reach target torque per job requirement (range 10,000-70,000 N·m). | |
| 6 | Release and reset: Release throttle, move control rod to reverse to disengage jaw. Rotate tong to align safety door opening with casing. Unlock door, move tong away to designated position. |
| Step | Action | Caution |
|---|---|---|
| 1 | Position tong: Align tong opening with casing joint. Ensure jaws fully wrap joint. Clean gripping surface (use cloth if oily or dirty). | |
| 2 | Lock safety door: Close and lock door. Supervisor reconfirms. Prevents tong falling if door not locked. | |
| 3 | Insert locating pin: Insert pin into break-out hole (marked with shadow). Ensure secure fit, no looseness. | |
| 4 | Low gear reverse operation: Shift lever up to low gear (3 rpm). Pull throttle fully to reverse direction. Use high torque (70,000 N·m) to break thread lock. | |
| 5 | Full loosening and removal: After joint loosens, continue low gear until threads separate. Lightly push throttle forward to disengage jaw. Align door opening with casing and move tong away. |
Shutdown sequence: Release throttle → shift lever to neutral → close hydraulic pump motor → open bypass valve to release system pressure → cut main power.
Clean equipment: Wipe tong body, jaw gripping surfaces, hose fittings. Remove oil, mud, and debris. Pay attention to safety door gaps.
Site organization: Remove safety tape and cones. Move tong to designated storage location. Hang "Cleaned – Ready for next use" tag. Fill out operation log (time, casing size, torque parameters, equipment condition).
Maintain clear communication throughout operation. Operator and supervisor use fixed hand signals or two-way radio. No unauthorized operation.
Torque adjustments must follow job plan. Do not exceed rated torque (prevents pipe damage and gear fracture).
Pause after every 10 casing joints to inspect: jaw wear, locating pin condition, hydraulic hose sealing.
In extreme cold, hydraulic oil warm-up must be at least 20 minutes. Do not force start at low temperature.
Do not start equipment with safety door unlocked or locating pin missing.
Do not use "snap break" (sudden throttle pull) for break-out – causes gear impact damage.
Do not place hands near rotating parts or step across hydraulic hoses. Do not stand under or place tools below tong body.
Do not use tong outside rated casing range (7″-20″).
Do not adjust relief valve pressure or remove safety interlock devices without authorization.
For operation training, safety support, or to request a copy of the full manual, please contact us:
info@hyrig.com
We provide comprehensive technical support and training for all TEDA casing power tongs, including the KT20000.