An LPG transfer pump must handle liquefied petroleum gas (propane, butane, or mixtures) safely, with zero or minimal leakage, and often from pressurized storage. Our API 610 VS6 and OH2 pumps cover two distinct installation scenarios – in‑tank submerged service and above‑ground horizontal service. Both designs fully comply with API 610 11th/12th edition (ISO 13709) , but with different structural types as defined by the standard.
API 610 VS6 – Submerged In‑Tank LPG Pump
Structure match check: API 610 VS6 is defined as a vertical, single‑casing, submerged pump with the driver and hydraulics fully immersed in the pumped liquid. It is the correct standard type for in‑tank installation with no external shaft seal.
Why VS6 for LPG?
Zero dynamic seal – Eliminates mechanical shaft seal completely. The motor is submerged in oxygen‑free LPG, so no external leakage path. Meets strict environmental regulations (LDAR, fugitive emissions).
Top‑pull design – Entire assembly withdraws through the tank nozzle without emptying or degassing the tank. Maintenance downtime reduced over 70%.
Intrinsically safe – Submerged motor runs in LPG, no explosion risk, no external purging. ATEX / IECEx ready.
Low NPSH – Optional inducer prevents cavitation, critical for high‑vapour‑pressure LPG.
Typical performance – Flow 5 – 800 m³/h, head up to 600 m, temperature -45°C to +50°C, pressure up to 2.5 MPa.
Typical VS6 applications
LPG bullet tanks (mounded or above‑ground)
Spherical LPG storage vessels
Railcar/truck unloading from pressurized tanks
Peak‑shaving plants
API 610 OH2 – Horizontal Above‑Ground LPG Pump
Structure match check: API 610 OH2 is defined as a horizontal, single‑stage, overhung pump with foot‑mounted casing, back pull‑out design, and centerline support (or foot‑mounted for lower temperatures). It is widely used for above‑ground LPG transfer where NPSHa is sufficient and a mechanical seal is acceptable with proper seal plans.
Why OH2 for LPG?
Compact, economical – Lower cost than VS6 when NPSHa is adequate and above‑ground installation is preferred.
Easy maintenance – Back pull‑out allows seal and rotor removal without disconnecting piping.
API 682 seal compatibility – Tandem or double mechanical seals with Plan 52 (unpressurized buffer) or Plan 53A (pressurized barrier) ensure zero fugitive emissions.
High efficiency – Over 80% efficiency for LPG’s low viscosity.
Wide range – Flow 5 – 2000 m³/h, head up to 250 m, temperature -45°C to +80°C, pressure up to 25 bar.
VSD ready – For variable flow control.
Typical OH2 applications
LPG terminal truck / railcar loading racks
Pipeline booster stations (above ground)
Refinery LPG feed pumps
Bulk LPG transfer between storage spheres
Comparison & Selection Guide
| Feature | VS6 (Submerged) | OH2 (Horizontal) |
|---|---|---|
| API 610 type | VS6 – vertical submerged, single‑casing | OH2 – horizontal overhung, foot‑mounted |
| Location | Inside tank, fully submerged | Above ground, external |
| Mechanical seal | None – zero leakage | API 682 tandem/double seal with barrier fluid |
| NPSH requirement | Very low (inducer optional) | Requires sufficient NPSHa from tank |
| Maintenance | Top‑pull, no tank emptying | Back pull‑out, piping remains |
| Typical max head | 600 m | 250 m |
| Typical max flow | 800 m³/h | 2000 m³/h |
| Best for | Bullet tanks, spheres, tight NPSH | Terminals, pipelines, loading racks |
| Cost | Higher initial, lower seal maintenance | Lower initial, seal maintenance required |
Why choose our API 610 LPG pumps?
Full API 610 compliance – Both VS6 and OH2 types verified per standard definitions.
Safety first – VS6: zero leakage. OH2: tandem seals with leak detection.
Short lead time – Standard sizes ex‑stock; custom designs competitive delivery.
Global spare parts support – Impellers, shafts, bearings, seals, and full casings shipped worldwide.
Lower total cost – Competitive price + long MTBR + application‑matched selection.
Quality assurance (both types)
ISO 9001:2015 certified.
API 610 performance test, mechanical run test with vibration & bearing temperature monitoring.
NPSH test verification (VS6 with inducer test).
Hydrostatic test of pressure‑containing components.
Material traceability EN 10204 3.1 / 3.2.
How to specify your LPG transfer pump
Please provide: flow (m³/h), head (m), operating temperature (°C), NPSHa available (m), tank type (bullet, sphere, or above‑ground), installation preference (in‑tank VS6 or external OH2), and emission regulations. We will recommend the correct API 610 pump type, material class, seal plan (for OH2), and driver details.
Contact us
For a quotation or technical discussion on LPG transfer pumps (API 610 VS6 or OH2):
info@hyrig.com
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.