The MCM 250 Mechanical Seal, available in P25MS/TT and PM25MS/TT, is a high-performance Type 1 single-ended unbalanced seal engineered for MCM 250 series slurry pumps and centrifugal pumps. Featuring a standard 2.5-inch (63.5mm) shaft diameter, it boasts wear-resistant friction pairs (SiC/TC or TC/TC), corrosion-resistant SS316 metal components, and Viton O-rings (-20°C~+220°C) to handle harsh working conditions. With a maximum pressure of 16 bar (21 bar short-term) and surface speed up to 20 m/s, this seal excels in sealing slurries, wastewater, and fluids with solid particles. Easy to install with precise alignment and uniform bolt tightening (7 N・m torque), it ensures reliable, long-lasting performance. Ideal as a direct replacement for compatible seal part numbers, it delivers exceptional durability and leak-proof sealing for industrial pumping applications. Contact info@hyrig.com for inquiries or technical support.
Conatct For Details
DetailReview(0)Additional

Mechanical Seal for MCM 250 P25MS/TT & PM25MS/TT

1. Shaft Size

  • Standard shaft diameter: 2.5 inches (63.5 mm)

2. Material Configuration

Standard configuration (P25MS/TT):

ComponentMaterial
Rotating / stationary seal facesSilicon Carbide (SiC) / Tungsten Carbide (TC) or Tungsten Carbide (TC) / Tungsten Carbide (TC) — excellent wear and particle resistance
Auxiliary seal (O‑rings)Viton, operating range: -20°C to +220°C
Metal components (springs, retainers, pins)Stainless Steel 316 (SS316) — corrosion resistant

3. Performance Parameters

  • Structure: Single‑ended, unbalanced, Type 1 mechanical seal

  • Pressure: ≤ 16 bar (short‑term up to 21 bar)

  • Temperature: -20°C to +220°C (depending on elastomer)

  • Surface speed: ≤ 20 m/s

  • Applicable media: Slurries, wastewater, fluids containing solid particles

4. Installation Notes

  1. Cleaning – Thoroughly clean the shaft, shaft sleeve and seal chamber to remove burrs and contaminants.

  2. Positioning – Install the stationary ring with anti‑rotation pin into the gland, and mount the rotating seal assembly on the shaft, ensuring proper alignment.

  3. Tightening – Tighten the gland bolts evenly in a crisscross pattern with a torque of approximately 7 N·m.

  4. Inspection – Rotate the shaft manually to check for no seizure or uneven wear.