Standard shaft diameter: 2.5 inches (63.5 mm)
Standard configuration (P25MS/TT):
| Component | Material |
|---|---|
| Rotating / stationary seal faces | Silicon Carbide (SiC) / Tungsten Carbide (TC) or Tungsten Carbide (TC) / Tungsten Carbide (TC) — excellent wear and particle resistance |
| Auxiliary seal (O‑rings) | Viton, operating range: -20°C to +220°C |
| Metal components (springs, retainers, pins) | Stainless Steel 316 (SS316) — corrosion resistant |
Structure: Single‑ended, unbalanced, Type 1 mechanical seal
Pressure: ≤ 16 bar (short‑term up to 21 bar)
Temperature: -20°C to +220°C (depending on elastomer)
Surface speed: ≤ 20 m/s
Applicable media: Slurries, wastewater, fluids containing solid particles
Cleaning – Thoroughly clean the shaft, shaft sleeve and seal chamber to remove burrs and contaminants.
Positioning – Install the stationary ring with anti‑rotation pin into the gland, and mount the rotating seal assembly on the shaft, ensuring proper alignment.
Tightening – Tighten the gland bolts evenly in a crisscross pattern with a torque of approximately 7 N·m.
Inspection – Rotate the shaft manually to check for no seizure or uneven wear.
For further inquiries or technical support, please contact us at:
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.