The Nitric Acid Pump is an API 610 Type OH2 horizontal, single‑stage, overhung, centerline‑mounted centrifugal pump specifically engineered for handling nitric acid (HNO₃) in chemical processing, fertilizer production, and metal treatment facilities. The pump fully complies with API 610 11th Edition and ISO 13709 standards.
In nitric acid plants, the pump transfers acid at various concentrations (typically 30–98%) and temperatures (ambient to 120°C) between absorption towers, bleachers, storage tanks, and loading stations. Nitric acid is strongly oxidizing and corrosive, requiring careful material selection and robust seal design.
The OH2 configuration — radially split casing, end‑suction top‑discharge, back pull‑out design — provides reliable, continuous operation with easy maintenance access.
As a specialized China API 610 pump manufacturer, we produce nitric acid pumps with corrosion‑resistant alloys to meet the demanding requirements of acid service.
Primary Media:
Nitric acid (HNO₃) — dilute to concentrated (5–98%)
Mixed acid (HNO₃ + H₂SO₄, HNO₃ + HF)
Nitrate solutions
Fluid Characteristics:
Corrosivity: Highly corrosive, especially at elevated temperatures and higher concentrations
Oxidizing nature: Promotes passive film formation on certain stainless steels (304/316), which actually resists corrosion
Temperature range: Ambient to 120°C (higher with special alloys)
Concentration: 0–100% — corrosion resistance varies with concentration
Material Selection (Critical for Nitric Acid):
| Concentration / Temp | Recommended Material |
|---|---|
| Dilute (≤30%), ambient | 304L or 316L stainless steel |
| Medium (30–70%), ambient | 304L or 316L |
| Concentrated (70–98%), ambient | 304L, 316L, or High Silicon Stainless Steel (SS920, SS940) |
| Concentrated, elevated (>50°C) | High Silicon Stainless Steel, Duplex 2205, Super Duplex 2507 |
| All concentrations, high temp | High Silicon SS (better resistance than standard 304/316) |
| Extremely corrosive | Zirconium, Titanium (TA2), Tantalum (high cost) |
Not suitable: Carbon steel, cast iron, aluminum, most copper alloys — rapid corrosion in nitric acid.
Elastomers:
Use PTFE, FEP, or FFKM (Kalrez). EPDM and Buna‑N degrade rapidly in nitric acid.
| Parameter | Range |
|---|---|
| Flow rate (Q) | 3 ~ 2,600 m³/h |
| Total head (H) | 4 ~ 300 m |
| Operating temperature | -20°C ~ +150°C (dependent on material) |
| Design pressure | Up to 7.5 MPa (75 bar) |
| Flange rating | ASME Class 150 / 300 |
| Materials | 304L/316L SS, high silicon SS, duplex, titanium |
| Seals | API 682 compliant, Plan 11/52/53 (tandem/double for fuming acid) |
Step 1: Define Operating Conditions
Flow, head, temperature, concentration (%HNO₃)
Presence of chlorides or other impurities (may require duplex)
Required NPSH available
Step 2: Select Material Based on Concentration & Temperature
Dilute/cold: 304L or 316L
Concentrated/cold: 316L or high silicon SS
Concentrated/hot (>60°C, >80%): High silicon SS (e.g., SS920) or duplex
Fuming red nitric acid: Titanium or high silicon SS
Step 3: Determine Pump Size and Speed
Single stage OH2 covers most nitric acid transfer duties
Select operating point at 70–120% of BEP for best reliability
Step 4: Specify Seal System
Single mechanical seal with Plan 11 (internal recirculation) acceptable for dilute/cold nitric acid
For concentrated or hot acid: Tandem seal with Plan 52 (buffer fluid) to prevent leakage
For fuming nitric acid (red fuming HNO₃): Double seal with Plan 53B, faces silicon carbide vs. carbon
Step 5: Auxiliary Features
Centerline mounting standard (acid may be warm)
Water‑cooled bearing housing if operating temperature >100°C
Casing drain with acid‑resistant valve
Minimum flow recirculation (ARC valve) recommended
| Feature | Benefit for Nitric Acid |
|---|---|
| Back pull-out design | Rotating assembly can be removed without disturbing piping — simplifies seal and bearing maintenance in corrosive environment |
| Centerline mounting | Accommodates thermal expansion at elevated temperatures; prevents misalignment |
| Radially split casing | Robust pressure containment; easy to inspect and clean |
| Closed impeller (316L/high silicon) | Dynamically balanced; renewable wear rings extend casing life |
| API 682 seal chamber | Accepts tandem/double seals for zero leakage of hazardous acid |
| Corrosion resistant bolting | A193 B8M (316 SS) or Hastelloy fasteners |
| Heavy duty shaft | Minimizes deflection, extends seal life |
| Renewable wear rings | Replaceable without changing casing; hard faced to resist galling |
| Parameter | Recommendation |
|---|---|
| Pump Type | API 610 Type OH2 — horizontal, single stage, overhung |
| Capacity | As required (typically 10–500 m³/h for acid transfer) |
| Head | As required (up to 150 m) |
| Temperature | Up to 120°C |
| Casing | 316L or High Silicon SS (SS920) |
| Impeller | 316L or High Silicon SS, closed |
| Shaft | 17-4PH SS (or High Silicon SS) |
| Wear rings | 316L with hard facing |
| Mechanical seal | Single Plan 11 (dilute), Tandem Plan 52 (concentrated), Double Plan 53B (fuming acid) |
| Seal faces | Silicon carbide vs. carbon |
| Gaskets | PTFE or FFKM |
| Flange rating | ASME Class 150 RF |
| Bearing cooling | Water cooled (if >100°C) |
API 610 11th Edition compliance — full international standard
Corrosion resistant alloys — 304L, 316L, high silicon SS, duplex, titanium available
Proven in nitric acid service — used in chemical and fertilizer plants
Competitive cost — typically 20–30% lower than Western brands
Lead time — 16–24 weeks for standard stainless steel
Complete documentation — performance curves, GA drawings, API datasheet, material certs
Factory testing — hydraulic performance, mechanical run, NPSH
Spare parts — seals, wear rings, bearings stocked
| Parameter | Specification |
|---|---|
| Pump Type | API 610 Type OH2 — horizontal, single stage, overhung, centerline mounted |
| Medium | Nitric acid (HNO₃), 5–98% |
| Temperature | -20°C to +120°C (higher optional) |
| Materials | 304L, 316L, High Silicon SS, duplex, titanium |
| Seals | API 682 Plan 11/52/53B |
| Maintenance | Back pull-out design |
| Certification | API 610 11th Edition |