HYRIG can supply the TSC HM series desilters range and its spare parts. This page provides answers to frequently asked questions about the operation and maintenance of the TSC HM series desilters.
Q1: What is the normal working pressure for the HM desilter?
A: The normal working pressure is 0.2-0.4 MPa. If the pressure is too low, the underflow will be too much.
Q2: How do I judge if the hydrocyclone is working normally?
A: Observe the shape of the underflow at the nozzle. An umbrella shape means normal operation. A solid column means overfeeding, and the inlet valve should be partially closed.
Q3: What do I do if the inlet pipe is blocked by mud cake?
A: Clear the mud cake from the inlet pipe.
Q4: What kind of grease should be used for the vibrating motor?
A: Only LGHP2 high temperature lubricating grease (SKF company) is recommended. Using other grease may damage the motor.
Q5: How often should the vibrating motor be lubricated?
A: Add LGHP2 grease after the motor has worked for 2000 hours. If the motor case temperature exceeds 90°C, halve the lubrication cycle for every additional 10°C.
Q6: How often should the hydrocyclones be checked for wear?
A: Check periodically. Replace the worn parts if the thickness decreases by 50%.
Q7: Does HYRIG supply TSC HM desilter spare parts?
A: Yes. HYRIG supplies the TSC HM series desilters and matching spare parts, including hydrocyclone cones, screen decks, clamps, and collecting chutes.
For TSC desilter technical support and spare parts, contact HYRIG: info@hyrig.com