Correct installation of the Upper IBOP 110103-500 on a VARCO TDS-4SA top drive ensures reliable well control and prevents thread damage or leakage.
Inspect the IBOP – Check for shipping damage, clean all surfaces.
Verify threads – Confirm top connection (4-1/2" IF female) matches TDS-4SA spindle.
Check seal condition – Ensure NBR seals are not cracked or hardened.
Prepare thread compound – Use API 7-1 approved thread lubricant (e.g., 31% zinc compound).
| Step | Action |
|---|---|
| 1 | Apply thread compound evenly to both the IBOP top threads and TDS-4SA spindle threads. |
| 2 | Hand-thread the IBOP onto the spindle until finger tight. |
| 3 | Use a torque wrench to tighten to 13,500 – 15,000 N·m (10,000 – 11,000 ft·lbs). |
| 4 | Attach the T-handle and verify smooth operation. |
| 5 | Connect the bottom string to 3-1/2" IF male thread (use same compound). |
Per API 16D, perform these tests before drilling:
Low-pressure test: Close the IBOP and apply 500 psi from below. Hold 5 minutes. No visible leakage.
High-pressure test: Apply 5,000 psi from below. Hold 5 minutes. No pressure drop.
Shell test (optional): Open the IBOP, apply 7,500 psi to the body. No leakage.
| Interval | Action |
|---|---|
| Daily / each tour | Cycle the valve fully open and closed. Check for smooth operation. |
| Weekly | Visual inspection for damage or corrosion. |
| Per API 16D (14 days) | Pressure test (low and high). Record results. |
| After 300 cycles or 6 months | Replace seals (repair kit). Inspect ball and seats. |
| After a well control event | Disassemble, inspect, replace seals regardless of cycle count. |
The 110103-500 uses a standard NBR seal kit. Replacement procedure:
Remove IBOP from top drive.
Unscrew end pieces (use proper tools).
Extract ball, seats, and seals.
Clean all components with solvent.
Install new seals (lubricate with silicone grease).
Reassemble and torque end pieces to specification.
Pressure test before returning to service.
Repair kit part number: Contact info@hyrig.com for kit details.
| Problem | Possible Cause | Solution |
|---|---|---|
| Hard to turn | Mud residue inside | Flush with clean fluid, lubricate |
| Hard to turn | Differential pressure too high | Equalize pressure before operating |
| Leaks when closed | Worn seat or ball | Replace seals, inspect ball |
| Thread galling | Insufficient thread compound | Clean threads, reapply compound |
| Cannot close fully | Debris in ball cavity | Remove IBOP, disassemble and clean |
Always verify zero pressure before removing the IBOP.
Use proper lifting equipment – IBOP weight approx. 55 kg (120 lbs).
Wear gloves when handling thread compound.
Never use pipe wrenches on the IBOP body – use the T-handle only.
For repair kits, special tools, or field service assistance:
Email: info@hyrig.com
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.