HYRIG can supply the XBSY SB series solid control sand pumps range and its spare parts. This page provides answers to frequently asked questions about the operation and maintenance of the XBSY SB series sand pumps.
Q1: Can the XBSY sand pump run dry?
A: No. No-load running must not exceed 5 seconds. The pump must be filled with liquid before startup to avoid mechanical seal damage.
Q2: What is the primary and auxiliary seal?
A: The primary seal is a mechanical seal with hard alloy faces. The auxiliary seal is a packing seal. The packing should only be tightened after the mechanical seal fails.
Q3: What lubrication is required for the bearings?
A: Bearings can use No. 30 oil (change every 1500 hours) or No. 3 lithium-based grease (add 40-50 g every 1000 hours). Oil and grease must not be mixed.
Q4: What is the maximum operating temperature for the bearings?
A: The temperature at the bearings must not exceed 80°C during operation.
Q5: What should I do if the pump vibrates or makes abnormal noise?
A: Immediately shut off the power supply. Check for impeller wear, bearing wear, loose connections, or cavitation. Replace worn parts or improve suction conditions.
Q6: How often should the mechanical seal be replaced?
A: The mechanical seal should be replaced when it fails or shows visible damage. Disassembled mechanical seals should be replaced.
Q7: Does HYRIG supply XBSY sand pump spare parts?
A: Yes. HYRIG supplies the XBSY SB series sand pumps and matching spare parts, including mechanical seals, shaft sleeves, impellers, bearings, and oil seals.
For XBSY sand pump technical support and spare parts, contact HYRIG: info@hyrig.com