YUKEN MPA/MPB/MPW Pilot Check Valve Series (Hydraulic Lock)
Overview:
HYRIG can supply the YUKEN MPA, MPB, and MPW series and related hydraulic components. These sandwich-mounted pilot-operated check valves allow free flow in one direction and blocked flow in reverse, which can be released by pilot pressure.
| Model Code | Size | Controlled Lines | Cracking Pressure | Max Flow |
|---|---|---|---|---|
| MPW-03-2-40 | NG10 | A & B | 0.2 MPa | 70 L/min |
| MPW-01-2-40 | NG6 | A & B | 0.2 MPa | 30 L/min |
| MPA-03-2-40 | NG10 | A | 0.2 MPa | 70 L/min |
| MPB-03-2-40 | NG10 | B | 0.2 MPa | 70 L/min |
| MPW-06-2-10 | NG20 | A & B | 0.2 MPa | 200 L/min |
Data source: YUKEN catalog and distributor listings.
For the NG10 A&B dual-line configuration, view YUKEN MPW-03-2-40.
Note: MPA/MPB/MPW are for load-holding only. For smooth control of vertical loads, consider a counterbalance valve (MHA/MHB).
| Parameter | 01 (NG6) | 03 (NG10) | 06 (NG20) |
|---|---|---|---|
| Mounting Standard | ISO 4401-03 | ISO 4401-05 | ISO 4401-06 |
| Mounting Bolt Pattern | 4 × M5 | 4 × M6 | 4 × M8 |
| Approx. Weight | 1.1 kg | 2.0 kg | 4.5 kg |
MPA = A-line lock, MPB = B-line lock, MPW = dual A&B lock. The cracking pressure code (2/4 = 0.2/0.4 MPa) must match the original circuit. The 40 series (01/03 size) and 10 series (06 size) have unchanged installation dimensions.
Need to confirm whether single (MPA/MPB) or dual (MPW) locking is required? Contact HYRIG with your circuit details, and we will recommend the correct configuration.
Used for load-holding and pilot-line isolation in hydraulic systems, particularly where a pilot signal is available to release the check valve. Common in clamping, mold-locking, and lifting circuits.
Disclaimer: YUKEN is a registered trademark of YUKEN KOGYO CO., LTD. HYRIG is an independent supplier of hydraulic components and is not affiliated with YUKEN KOGYO CO., LTD.