Product Overview
The HYRIG BB4 Hydrotreating Charge Pump is a heavy-duty, multi-stage, horizontal split case (axially split), between-bearing centrifugal pump, fully compliant with API 610 (ISO 13709) standards. Specifically engineered for hydrotreating (hydrodesulfurization, hydrodenitrogenation) unit charge service in refineries – including naphtha, kerosene, diesel, gas oil (VGO), and other middle distillate hydrotreaters – this pump features a horizontal split casing (upper and lower half) and between-bearing rotor support with multi-stage diffuser hydraulics to achieve high heads (500 – 2500 m) while handling high pressure, high temperature, hydrogen rich hydrocarbon feedstocks mixed with recycle gas.
Hydrotreating charge pumps boost feed from low pressure (typically 5–20 bar) up to reactor pressure (up to 250 bar) in a single machine. The BB4 horizontal split case design offers exceptional maintainability: the entire rotor, bearings, and seals can be inspected by removing the upper casing half without disturbing suction or discharge piping – a critical advantage in refinery turnarounds where speed is essential.
Key Technical Parameters
Pump Type: API 610 BB4 Horizontal Split Case, Multi‑Stage (3 to 12 stages), Between‑Bearing Centrifugal Pump
Flow Range: 50 – 1200 m³/h (depending on hydrotreater capacity)
Head Range: 500 – 2500 m (higher with additional stages)
Working Temperature: Up to 400°C (typical: 150°C for naphtha, 350°C for VGO)
Design Pressure: Up to 250 bar (reactor loop pressure)
Structure: Horizontal split case (axially split), between-bearing dual support, with single suction or double suction first stage impeller for low NPSH.
Seal Standard: API 682 mechanical seal – typically tandem dry gas seal (Plan 72+75) for high pressure hydrogen/hydrocarbon service, or optional pressurized dual seal (Plan 53B).
Materials: High strength chrome steel casing (ASTM A217 WC6, WC9, or C12A for high temperature); 12% chrome (CA‑15) or 17-4 PH for impellers and diffusers; hardened stellited wear rings; materials selected per NACE MR0175/ISO 15156 for H₂S and hydrogen embrittlement resistance.
Application: Hydrotreating unit charge pump (feed from storage or upstream unit to reactor) for naphtha, kerosene, diesel, light gas oil (LGO), heavy gas oil (HGO), vacuum gas oil (VGO).
Key Features
API 610 BB4 Compliance – Built to the highest international standard for heavy duty, high pressure, continuous refinery pumps.
Horizontal Split Casing Maintainability – Upper half casing removal exposes the complete rotor, internal clearances, bearings, and seals without disturbing piping, dramatically reducing maintenance time during turnarounds.
Extreme High Head & Pressure – Up to 12 stages deliver up to 2500 m head, boosting feed directly to reactor pressure in a single pump.
Hydrogen & H₂S Service – Materials strictly controlled for hydrogen embrittlement, high temperature hydrogen attack (HTLA), and wet H₂S cracking.
High Temperature Integrity – Centerline support feet on lower casing maintain alignment up to 400°C; water jacketed bearing housings and thermal barrier zones protect bearings and seals.
Low NPSH First Stage – Double suction first impeller or inducer option for low available suction head typical of hydrotreater feed surge drums.
High Efficiency Hydraulics – CFD optimized diffuser/impeller stages achieve up to 86% efficiency, reducing power consumption over 20+ year operation.
Fugitive Emission Control – API 682 tandem dry gas seal (Plan 72 nitrogen buffer + Plan 75 primary vent) ensures zero hydrogen/hydrocarbon leakage to atmosphere.
Superior Rotor Dynamics – Between-bearing design with short span, precision balanced multi-stage rotor (API 610 Grade G), tilting pad bearings, and forced oil or oil mist lubrication for vibration‑free high speed operation.
Ease of Inspection – Horizontal split allows internal clearance checks (wear rings, interstage bushings) without rotor removal – a significant time saver.
Typical Applications
Naphtha hydrotreater (NHT) charge pump – feed to reactor for sulfur removal from reformer feed
Kerosene / jet fuel hydrotreater charge pump
Diesel hydrodesulfurization (DHDS) unit charge pump (high pressure, moderate temperature)
Gas oil hydrotreater (GOHDS) / VGO hydrotreater charge pump (high temperature, high pressure)
Hydrotreating sections in integrated hydrocracking complexes (pre‑treat feed to hydrocracker)
Replacement of older radially split (BB3) pumps when maintenance access is a priority
Why HYRIG?
HYRIG combines refinery hydroprocessing expertise with API 610 BB4 design. Each BB4 Hydrotreating Charge Pump is engineered with horizontal split convenience, finite element verified pressure boundary, rotordynamics analysis for high speed stability, CFD optimized multi‑stage hydraulics, and API 682 seal support systems tailored to high pressure hydrogen service. Our BB4 pumps are installed in hydrotreaters worldwide, providing the reliability, efficiency, and maintainability demanded by modern refinery operations.
Contact Us
For technical quotation, multi‑stage hydraulic selection, or custom engineered solutions for your hydrotreating charge application, please email us at: info@hyrig.com
Our engineering team will respond within 24 hours with a pump selection optimized for your feed type, flow, head, and hydrogen service conditions.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.