A caustic pump handles sodium hydroxide (NaOH) solutions, commonly called caustic soda. Caustic is highly corrosive, especially at elevated temperatures and higher concentrations. It can cause stress corrosion cracking (SCC) in certain materials, particularly carbon steel and some stainless steels. Proper material selection is critical. Our API 610 OH2 centrifugal pump is specifically engineered for safe, reliable caustic service. This design fully complies with API 610 11th/12th edition (ISO 13709) .
Structure match check: API 610 OH2 is defined as a horizontal, single‑stage, overhung pump with foot‑mounted casing and back pull‑out design. This matches caustic service requirements because:
OH2 allows easy maintenance – back pull‑out for seal, impeller, bearing inspection without disturbing piping.
Corrosion resistant alloys (316SS, Alloy 20, Nickel, Monel, or Hastelloy) are readily available in OH2 construction.
High temperature capability – Caustic often handled at 50-120°C; centerline support optional for higher temperatures.
Sealing options – API 682 mechanical seals with appropriate flush plans to prevent caustic crystallization.
Why API 610 OH2 for caustic duty?
Corrosion resistance – Carbon steel is NOT acceptable for caustic above 50°C or higher concentrations. Wetted parts must be:
316SS for low temperature (<50°C), low concentration (<20%).
Alloy 20 (CN7M) for moderate temperature/concentration.
Nickel 200 or Monel 400 for high temperature (up to 120°C) and high concentration (up to 50%).
Hastelloy C276 for severe service (higher temps, chlorides).
High temperature capability – Caustic often handled at 80-120°C (e.g., in refinery caustic wash or neutralization). Specify centerline support above 100°C. Bearing housing cooling recommended above 120°C.
Sealing against crystallization – Caustic tends to crystallize on seal faces when temperature drops. API 682 Plan 11 (internal recirculation) with heated seal chamber or Plan 32 (external flush with water or dilute caustic) prevents crystallization. Double seals with heated barrier fluid for zero emissions.
Low NPSH – Caustic storage tanks may have low NPSHa. Optional inducer reduces NPSHr below 1 m, preventing cavitation and corrosion acceleration.
Wide hydraulic range – Flow 5 to 1500 m³/h, head up to 250 m, covering caustic transfer, metering, and circulation duties.
Key design features for caustic service
Materials – Casing: 316SS (CF8M, CF3M) for low duty; Alloy 20 (CN7M) for moderate; Nickel 200 or Monel 400 for high concentration/temperature; Hastelloy C276 for severe. Impeller/shaft: matching alloy. Gaskets: PTFE or expanded PTFE (no graphite). Fasteners: Alloy 20 or Hastelloy.
Stress corrosion cracking prevention – Avoid 304/316 austenitic stainless steels above 80°C in concentrated caustic (risk of SCC). Use Nickel or Alloy 20. Solution annealed condition.
Temperature management – Centerline support for >100°C. Thermally insulated stuffing box to maintain seal temperature above crystallization point. Steam tracing or electric heat tracing on seal housing optional.
Sealing – Cartridge mechanical seal. Plan 11 recirculation (if liquid is clean). Plan 32 external water flush to dilute caustic at seal face (common). Double seals with Plan 53A (pressurized barrier fluid) for zero leakage. Seal faces: SiC vs. SiC (chemically resistant).
Impeller – Closed, radially balanced. For low NPSH, optional inducer. For large flows, double‑suction first stage to reduce NPSHr.
Bearings – Anti‑friction, oil bath or oil mist. For hot caustic (>100°C), bearing housing cooling fan or water jacket required.
Drain and vent – Full drain for complete washing during maintenance (caustic is hazardous).
Typical performance range
| Parameter | Value |
|---|---|
| Flow rate | 5 – 1500 m³/h |
| Head | Up to 250 m |
| Temperature | Up to 120°C (higher with special alloys) |
| Pressure rating | Up to 25 bar |
| NPSHr (with inducer) | As low as 0.5 m |
| Speeds | 1450 / 2900 / 3600 rpm |
| Concentration range | Up to 50% NaOH (higher with heating) |
Typical applications
Caustic transfer from storage to day tank or process.
Caustic wash in refinery (mercaptan removal, neutralization).
Chemical plant caustic circulation (e.g., chlorine plants, pulp & paper).
Wastewater pH adjustment – caustic dosing.
Alumina refining – Bayer process caustic circulation.
Soap and detergent manufacturing.
Why choose our API 610 OH2 caustic pump?
Full API 610 compliance – Performance test, NPSH test (inducer), mechanical run test.
Correct material selection – We recommend the optimal alloy (316SS, Alloy 20, Nickel, Monel, Hastelloy) for your temperature and concentration to avoid SCC and general corrosion.
Prevention of caustic crystallization – Seal plans with heating or external flush keep seal faces clean.
Short lead time – Standard 316SS pumps ex‑stock; Alloy 20 / Nickel / Monel 10-14 weeks.
Global spare parts support – Casings, impellers, shafts, seal cartridges, bearings shipped worldwide.
Quality assurance
ISO 9001:2015 certified.
API 610 mechanical run test (4 hours minimum) with vibration and bearing temperature monitoring.
Hydrostatic test of casing.
Material traceability EN 10204 3.1 / 3.2.
PMI for alloy components.
NDE – MT, PT, UT (for nickel alloys) as required.
Stress corrosion cracking mitigation documented.
How to specify your caustic pump
Please provide: flow (m³/h), head (m), temperature (°C), NaOH concentration (%), NPSHa (m), presence of chlorides or other contaminants, and required emission regulation (zero leakage). We will recommend alloy grade, centerline support (yes/no), inducer (yes/no), seal plan (11/32/53A), bearing cooling, and driver details.
Contact us
For a quotation or technical discussion on caustic pumps (API 610 OH2) :
info@hyrig.com