API 610 OH2 single‑stage, overhung pump for solvent service (e.g., toluene, xylene, hexane, acetone, methanol). Corrosion resistant 316SS or Alloy 20. Low NPSH design, zero leakage sealing options. Suitable for chemical transfer, extraction, and washing. China OH2 pump manufacturer.

Conatct For Details
DetailReview(0)Additional

A solvent pump must handle a wide variety of organic and polar solvents – from hydrocarbons (toluene, xylene, hexane) to oxygenated compounds (acetone, methanol, ethanol, MIBK). Solvents may be volatile, flammable, toxic, or corrosive. Many have very low viscosity and high vapour pressure, requiring careful attention to net positive suction head (NPSH) and sealing. Our API 610 OH2 centrifugal pump is specifically engineered for safe, reliable solvent transfer in chemical plants, refineries, pharmaceutical units, and extraction processes. This design fully complies with API 610 11th/12th edition (ISO 13709) .

Structure match check: API 610 OH2 is defined as a horizontal, single‑stage, overhung pump with foot‑mounted casing and back pull‑out design. This matches solvent service requirements because:

  • OH2 provides easy maintenance – back pull‑out for seal, impeller, bearing inspection without disturbing piping. Important for frequent solvent change‑over or cleaning.

  • Corrosion resistant materials (316SS, Alloy 20, Hastelloy) are available in OH2 construction.

  • Low NPSH – Many solvents have high vapour pressure; inducer or high‑suction specific speed impeller reduces NPSHr below 1 m.

  • Leak‑tight sealing – API 682 tandem or double mechanical seals with barrier fluid prevent fugitive emissions of volatile solvents.

Why API 610 OH2 for solvent duty?

  • Material compatibility – Solvents can attack elastomers, gaskets, and metals.

    • 316SS suitable for many organic solvents (toluene, xylene, hexane, acetone, methanol) – but verify compatibility with your specific solvent.

    • Alloy 20 or Hastelloy for aggressive solvents (e.g., acetic acid, chlorinated solvents, or high temperature aromatic mixtures).

    • Gaskets: PTFE or perfluoroelastomer (FFKM) – no nitrile or EPDM unless verified.

    • Mechanical seal faces: SiC vs. carbon (standard) or SiC vs. SiC for abrasive solvents.

  • Low NPSH – Many solvents (especially hydrocarbons) have high vapour pressure, causing cavitation risk. Inducer reduces NPSHr to as low as 0.5 m, allowing operation from low‑level tanks or drums.

  • Zero leakage sealing – Solvents are often volatile and flammable. Tandem seals with Plan 52 (unpressurized buffer) or double seals with Plan 53A (pressurized barrier) are standard recommendations. Plan 11 (internal recirculation) may be used for non‑volatile, non‑hazardous solvents.

  • Wide hydraulic range – Flow from 5 to 1000 m³/h, head up to 200 m. Solvent pumps typically operate at moderate heads. Higher speeds (3600 rpm) are common due to low viscosity.

  • Fire resistant – OH2 construction with fire‑safe seals and bearing housing materials supports plant safety requirements.

Key design features for solvent service

  • Materials – Casing: 316SS (CF8M/CF3M) or higher alloy. Impeller/shaft: 316SS, 17-4PH, or matching alloy. Wear rings: 17-4PH or Stellite. Gaskets: PTFE or FFKM.

  • Low NPSH design – Inducer standard if NPSHa < 3 m. For high vapour pressure solvents (e.g., pentane, hexane), inducer is strongly recommended.

  • Sealing – API 682 cartridge seals.

    • Plan 11 (recirculation) for clean, non‑volatile solvents (e.g., glycol, some alcohols).

    • Plan 52 (tandem, unpressurized) or Plan 53A (dual pressurized) for volatile, flammable, or toxic solvents.

    • For solvents with tendency to polymerize or crystallize, Plan 32 (external clean solvent flush) to keep seal faces clean.

  • Bearing housing – Standard oil bath for moderate temperatures. For high speed (3600 rpm) or hot solvents (>100°C), pure oil mist recommended. Labyrinth seals prevent contaminant ingress.

  • Casing – Foot‑mounted for temperatures below 100°C; centerline support if solvent is handled above 100°C (e.g., hot aromatics).

  • Static seals – All O‑rings and gaskets to be solvent‑resistant (PTFE, FFKM). No elastomers that swell or dissolve.

  • Vent and drain – Full connections for safe flushing and de‑inventory before maintenance – critical for flammable solvents.

Typical performance range

ParameterValue
Flow rate5 – 1000 m³/h
HeadUp to 200 m
Temperature-30°C to +150°C
Pressure ratingUp to 25 bar
NPSHr (with inducer)As low as 0.5 m
Speeds1450 / 2900 / 3600 rpm

Typical applications

  • Solvent transfer – from storage tanks to blending or process units.

  • Extraction processes – pumping solvent into extractors (e.g., aromatics extraction).

  • Washing / scrubbing – circulating solvent in wash columns.

  • Pharmaceutical manufacturing – handling alcohols, ketones, esters under clean conditions.

  • Paint and coating plants – pumping solvents to mix tanks or filling lines.

  • Refinery solvent deasphalting (SDA) – pumping propane or butane as solvent (high pressure, low NPSH – requires special attention).

Why choose our API 610 OH2 solvent pump?

  • Full API 610 compliance – Performance test, NPSH test (inducer), 4‑hour mechanical run test.

  • Material compatibility guarantee – We verify all wetted materials against your solvent safety data sheet (SDS) for corrosion, swelling, and elastomer compatibility.

  • Low NPSH reliability – Inducer ensures cavitation‑free operation for high vapour pressure solvents.

  • Zero fugitive emissions – Tandem/double seals with barrier fluid meet LDAR and environmental regulations.

  • Short lead time – Standard 316SS pumps with inducer and double seals available from stock; Alloy 20 / Hastelloy 8‑12 weeks.

  • Global spare parts support – Impellers, shafts, seal cartridges, bearings, casing shipped worldwide.

Quality assurance

  • ISO 9001:2015 certified.

  • API 610 mechanical run test with vibration and bearing temperature monitoring.

  • NPSH test verification (with inducer).

  • Hydrostatic test of casing.

  • Material traceability EN 10204 3.1 / 3.2.

  • PMI for alloy components.

  • NDE – MT, PT, UT as required.

How to specify your solvent pump

Please provide: flow (m³/h), head (m), solvent name and chemical composition, temperature (°C), specific gravity, vapour pressure (for NPSHa calculation), NPSHa available (m), presence of solids, toxicity / flammability classification, and any emission regulations. We will recommend inducer (yes/no), seal type and plan (11/52/53A), material grade (316SS/Alloy20/Hastelloy), gasket material, and driver details.

Contact us

For a quotation or technical discussion on solvent pumps (API 610 OH2) :

info@hyrig.com