HYRIG can supply the FESTO air preparation range. This overview groups the main component types — filter regulators (LFR), pressure regulators (LR), lubricators (LOE), and pressure gauges (MA) — and helps match the size to the air demand. Specific models and dimensions are covered on the individual model pages.
| Component types | Filter regulator (LFR), pressure regulator (LR), lubricator (LOE), pressure gauge (MA) |
| Sizes | MINI (40 mm), MIDI (55 mm), MAXI (76 mm) |
| Flow range | ~200 l/min (MINI) … 8000 l/min (MAXI) |
| Pressure range | 0.5–7 bar (MINI), 0.5–12 bar (MIDI/MAXI) |
| Filtration grades | 5 μm (standard), 40 μm (coarse) |
| Drain options | Manual, fully automatic (-A suffix) |
| Component | Function | When to use | Example model |
|---|---|---|---|
| LFR (filter regulator) | Filtration + pressure regulation | Air supply contains condensate or particulate; downstream pressure must be set | LFR-1/2-D-5M-O-MIDI-A |
| LR (pressure regulator) | Pressure regulation only | Air supply is already clean and dry; only pressure needs to be set | LR-1/2-D-O-I-MIDI |
| LOE (lubricator) | Oil mist lubrication | Downstream equipment requires lubricated air (legacy tools, air motors) | LOE-1/2-D-MIDI |
| MA (pressure gauge) | Local pressure indication | Operator needs a visual reading of line pressure | MA-63-10-R1/4-E-RG |
Data source: Technical data table.
The MINI size (40 mm grid) is used for point-of-use regulation on small valve terminals or individual machines, with a 0.5–7 bar range. The MIDI size (55 mm grid) is the most common choice for machine-level air preparation, with a 0.5–12 bar range and flow rates up to ~3500 l/min. The MAXI size (76 mm grid) is used for main air lines and large valve terminals, with flow rates up to 8000 l/min.
If the air supply contains condensate or particulate, choose an LFR filter regulator rather than a plain LR regulator — the LFR combines filtration and regulation in one body. If the downstream equipment requires lubrication, add an LOE lubricator after the regulator. Most modern FESTO cylinders and valves are designed for oil-free air, so confirm the equipment requirement before adding a lubricator.
Not sure which air preparation size and component combination matches your flow demand and air quality requirement? Send your flow rate, supply pressure, required downstream pressure, air quality class, and panel space, and we will confirm the component sizes and drain configuration. Explore the FESTO LFR filter regulator overview for the filter regulator range, or the FESTO LR pressure regulator overview for the regulator-only range.
Q: What is the difference between LR and LFR?
A: LR is a pressure regulator without filtration. LFR combines a 5 μm filter and a pressure regulator in one body. Choose LFR when the air supply requires filtration before regulation.
Q: Which size should I choose — MINI, MIDI, or MAXI?
A: MINI for point-of-use regulation on small machines (up to ~7 bar), MIDI for machine-level air preparation (up to ~3500 l/min, 12 bar), MAXI for main air lines and large valve terminals (up to 8000 l/min).
Q: Do I need a lubricator?
A: Only if the downstream equipment requires lubricated air. Many modern FESTO cylinders and valves are designed for oil-free air. Once lubricated air is used, the system must continue with lubricated air.
Q: What does the "-A" suffix mean on an LFR?
A: The "-A" suffix indicates a fully automatic condensate drain. Without the suffix, the drain is manual.
Q: What is the filtration grade of the standard LFR?
A: 5 μm. A 40 μm coarse filter is available for applications where finer filtration is not required.
For FESTO air preparation component selection and size confirmation, contact HYRIG: info@hyrig.com.