HYRIG can supply the JL series choke valve range and its replacement parts. The JLG65-70 is a fixed (positive) choke valve with a 65 mm nominal bore, engineered to provide a constant, predetermined pressure drop in high-pressure wellhead and manifold applications. It is manufactured to API 6A and API 16C standards and features a flange connection.
| Model Number | Nominal Diameter | Pressure (MPa) | A (mm) | B (mm) | Connection Type | Adjusting Mode | Actuator |
|---|---|---|---|---|---|---|---|
| JLG65-35 | 65 mm | 35 | 260 | 200 | Flange | Fixed | N/A |
| JLG65-70 | 65 mm | 70 | 228 | 228 | Flange | Fixed | N/A |
Data source: Technical data table.
Need a lower pressure rating? View the JLG65-35 Fixed Choke Valve or explore the full JL Choke Valve Series.
The exact footprint for the JLG65-70 configuration is:
Note: The 70 MPa fixed choke has a different footprint compared to the 35 MPa version. Verify your flange and piping dimensions before ordering.
The JLG65-70 utilizes a fixed choke (positive choke) design. It works by installing a fixed-size bean into the flow path. This creates a constant pressure drop and flow rate.
The "G" in the model code indicates a fixed design. It has no moving internal parts, making it highly durable for continuous production where a specific, unchanging restriction is required.
Looking for a replacement for your existing fixed choke valve? Here’s what to check:
This valve is specifically suited for:
Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.
Need help determining the correct fixed bean size for your flow rate? Tell us your upstream pressure, desired downstream pressure, and flow rate, and our engineers will recommend the correct orifice size.
HYRIG provides replacement parts for the JLG series, including:
See our JL Choke Valve Parts page for compatible maintenance kits.
Q: What is the working pressure of this model?
A: The JLG65-70 is rated for a working pressure of 70 MPa (10,000 psi).
Q: Does this valve have an adjustable handwheel?
A: No. Fixed choke valves use a fixed-size bean and do not have an adjustment mechanism.
Q: What is the difference in dimensions between this and the 35 MPa model?
A: The 70 MPa model has overall dimensions of 228 x 228 mm, while the 35 MPa model is 260 x 200 mm. Ensure you check your pipeline clearance.
Q: What standards does this valve meet?
A: It is manufactured according to API 6A and API 16C standards.
For JLG65-70 fixed choke valve selection and replacement parts, contact HYRIG: info@hyrig.com
Page last updated: 2026-11-08
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.