This guide provides step-by-step instructions for the proper installation and standard operation of the KHT9625 Casing Power Tong. Following these procedures ensures safe, efficient, and reliable performance during casing make-up and break-out operations.
Proper installation is critical for safe operation and equipment longevity. Follow these steps carefully:
| Step | Procedure | Key Requirements |
|---|---|---|
| 1. Hanging | Use a 3-ton pulley and ≥1/2″ wire rope. Set the hanging height to align with the casing joint level. | Ensure pulley and rope are rated for the load. |
| 2. Leveling | Adjust front/rear and crosswise leveling screws to ensure the tong is perfectly horizontal. | Prevents gear slippage and uneven wear. |
| 3. Back Guy | Secure a back guy line using ≥5/8″ wire rope at a 90° angle to the tong centerline. | Provides stability during high-torque operations. |
| 4. Cylinder Oil Fill | Use a hand pump to fill cylinder oil when the piston rod extends less than 1/4″. | Maintains proper hydraulic cylinder function. |
| 5. Pipe Connection | Connect hydraulic lines: High pressure port: NPT1; Low pressure return port: NPT1 1/4″. | Ensure tight, leak-free connections. |
Follow these steps for proper casing make-up:
Backup tong clamps pipe – Engage the backup tong to secure the lower pipe section.
Master tong clamps casing – Engage the master tong to grip the upper casing.
Use high gear for spinning – Run at high speed for fast thread engagement.
Switch to lower gears for torque – Shift down as needed to achieve target torque.
Reach target torque – Monitor torque gauge; stop when specified torque is reached.
Release master & backup tong – Disengage both tongs.
Open safety door – Unlock and open the safety door.
Remove tong – Lift and move the tong away from the wellhead.
Follow these steps for proper casing break-out:
Use low gear to loosen connection – Engage low gear for high torque to break the thread connection.
Switch to high gear for fast unthreading – Once loosened, shift to high gear for rapid spinning.
Release tongs – Disengage both master and backup tongs.
Remove tong from wellhead – Lift and clear the tong.
Adhere to these critical rules at all times to prevent accidents and equipment damage:
No gear shifting during operation – Always stop the rotation before changing gears. Shifting under load can damage the transmission.
Safety door must be closed during working – Never operate the tong with the safety door open. The door interlock prevents operation when open.
Align tong center with casing center – Misalignment can cause uneven gripping, thread damage, or tong component failure.
Pre-start check – Verify all connections, hydraulic pressure, and safety devices before each operation.
Proper jaw selection – Use the correct jaw size for the casing being handled (see jaw size chart).
Regular maintenance – Inspect wire ropes, pulleys, and hydraulic hoses for wear before each shift.
Emergency stop – Know the location of emergency shutdown controls.
| Problem | Possible Cause | Solution |
|---|---|---|
| Gear slipping | Tong not level | Re-level using adjustment screws |
| Excessive vibration | Back guy not at 90° angle | Reposition back guy wire rope |
| Slow cylinder response | Low oil level in cylinder | Use hand pump to refill cylinder oil |
| Hydraulic leak | Loose pipe connections | Tighten NPT fittings |
For installation assistance, operator training, or replacement parts, please contact us:
info@hyrig.com
We provide full technical support for all TEDA casing power tongs, including the KHT9625.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.