Proper safety practices and regular maintenance are essential for the safe and reliable operation of the KHT9625 Casing Power Tong. This guide provides critical safety cautions, a detailed maintenance schedule, and common troubleshooting solutions.
Adhere to all safety precautions to prevent injury and equipment damage:
Read manual completely before operation – Understand all functions, controls, and safety features before using the tong.
Wear protective clothing, helmet & safety boots – Always use appropriate personal protective equipment (PPE).
Operate only at the side of tong opening – Never stand in front of or behind the tong opening during operation.
Keep hands away from rotating parts – Do not touch moving components while the tong is running.
Cut off hydraulic supply during maintenance – Always disconnect hydraulic power before performing any inspection, repair, or cleaning.
Do not use over-pressure or over-torque – Stay within rated limits to avoid equipment failure and safety hazards.
Use only TEDA original spare parts – Non-original parts may compromise safety and performance, and void warranty.
Follow this maintenance schedule to ensure optimal performance and extended service life:
| Frequency | Maintenance Task |
|---|---|
| Before each use | Lubricate all fittings (grease points, rotating pins, and bearings). |
| Before each operation | Perform a test run without load to verify normal rotation and speed. |
| After each use | Clean the tong thoroughly. Apply anti-rust grease to exposed metal surfaces. |
| When moving | Seal all oil ports to prevent contamination and oil leakage. |
| Storage | Store in a dry, clean area away from the drill floor (avoid dust, moisture, and impact). |
| After 10 well jobs | Perform a full overhaul (disassemble, inspect, replace worn parts, re-calibrate). |
Quickly identify and resolve common issues with the KHT9625:
| Problem | Possible Cause | Solution |
|---|---|---|
| Tong not rotating | Hydraulic pressure too low / Valve failure | Check hydraulic system pressure. Replace faulty valve. |
| Slipping during operation | Incorrect jaw size / Tong not level / Worn dies | Verify jaw size matches casing. Re-level the tong. Replace worn dies. |
| Low torque output | Low cylinder oil / Worn or damaged seals | Replenish cylinder oil using hand pump. Inspect and replace seals. |
| Low speed (all gears) | Power station issue / Hydraulic motor failure | Repair or replace power station components. Service or replace hydraulic motor. |
Daily inspection – Before each shift, check hydraulic hoses, fittings, and wire ropes for wear or damage.
Hydraulic oil – Change hydraulic oil every 6 months or as specified by the power station manual.
Jaw dies – Inspect jaw die teeth regularly. Replace when wear exceeds 1 mm.
Fasteners – Check and retorque all bolts and nuts weekly.
Safety door interlock – Test the safety door interlock daily to ensure it stops operation when opened.
Keep the following genuine TEDA spare parts on site for quick replacement:
| Part | Recommended Quantity |
|---|---|
| Jaw dies (various sizes) | 2 sets per size |
| Seal kit | 1 kit |
| Brake belt | 1 piece |
| Hydraulic hoses | 2-3 pieces |
| Lubricating grease | As needed |
For safety training, maintenance assistance, or to order genuine TEDA spare parts, please contact us:
info@hyrig.com
We provide full technical support and original spare parts for all TEDA casing power tongs, including the KHT9625.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.