The KHT9625 casing power tong requires strict adherence to safety and maintenance procedures. Safety cautions: read manual before operation, wear protective clothing/helmet/boots, operate only at side of tong opening, keep hands away from rotating parts, cut hydraulic supply during maintenance, do not use over-pressure or over-torque, use only TEDA original spare parts. Maintenance schedule: lubricate fittings before each use, test run without load before operation, clean and apply anti-rust grease after use, store in dry clean area away from drill floor, seal oil ports when moving, full overhaul after 10 well jobs. Troubleshooting: no rotation (check pressure/replace valve), slipping (check jaw size/leveling/die wear), low torque (replenish cylinder oil/check seals), low speed (repair power station or hydraulic motor). Contact info@hyrig.com.

Conatct For Details
DetailReview(0)Additional

Proper safety practices and regular maintenance are essential for the safe and reliable operation of the KHT9625 Casing Power Tong. This guide provides critical safety cautions, a detailed maintenance schedule, and common troubleshooting solutions.


Safety Cautions (Must Read Before Operation)

Adhere to all safety precautions to prevent injury and equipment damage:

  • Read manual completely before operation – Understand all functions, controls, and safety features before using the tong.

  • Wear protective clothing, helmet & safety boots – Always use appropriate personal protective equipment (PPE).

  • Operate only at the side of tong opening – Never stand in front of or behind the tong opening during operation.

  • Keep hands away from rotating parts – Do not touch moving components while the tong is running.

  • Cut off hydraulic supply during maintenance – Always disconnect hydraulic power before performing any inspection, repair, or cleaning.

  • Do not use over-pressure or over-torque – Stay within rated limits to avoid equipment failure and safety hazards.

  • Use only TEDA original spare parts – Non-original parts may compromise safety and performance, and void warranty.


Maintenance Schedule

Follow this maintenance schedule to ensure optimal performance and extended service life:

FrequencyMaintenance Task
Before each useLubricate all fittings (grease points, rotating pins, and bearings).
Before each operationPerform a test run without load to verify normal rotation and speed.
After each useClean the tong thoroughly. Apply anti-rust grease to exposed metal surfaces.
When movingSeal all oil ports to prevent contamination and oil leakage.
StorageStore in a dry, clean area away from the drill floor (avoid dust, moisture, and impact).
After 10 well jobsPerform a full overhaul (disassemble, inspect, replace worn parts, re-calibrate).

Common Troubleshooting

Quickly identify and resolve common issues with the KHT9625:

ProblemPossible CauseSolution
Tong not rotatingHydraulic pressure too low / Valve failureCheck hydraulic system pressure. Replace faulty valve.
Slipping during operationIncorrect jaw size / Tong not level / Worn diesVerify jaw size matches casing. Re-level the tong. Replace worn dies.
Low torque outputLow cylinder oil / Worn or damaged sealsReplenish cylinder oil using hand pump. Inspect and replace seals.
Low speed (all gears)Power station issue / Hydraulic motor failureRepair or replace power station components. Service or replace hydraulic motor.

Additional Maintenance Tips

  • Daily inspection – Before each shift, check hydraulic hoses, fittings, and wire ropes for wear or damage.

  • Hydraulic oil – Change hydraulic oil every 6 months or as specified by the power station manual.

  • Jaw dies – Inspect jaw die teeth regularly. Replace when wear exceeds 1 mm.

  • Fasteners – Check and retorque all bolts and nuts weekly.

  • Safety door interlock – Test the safety door interlock daily to ensure it stops operation when opened.


Spare Parts Recommendation

Keep the following genuine TEDA spare parts on site for quick replacement:

PartRecommended Quantity
Jaw dies (various sizes)2 sets per size
Seal kit1 kit
Brake belt1 piece
Hydraulic hoses2-3 pieces
Lubricating greaseAs needed

Contact Us for Support

For safety training, maintenance assistance, or to order genuine TEDA spare parts, please contact us:

info@hyrig.com

We provide full technical support and original spare parts for all TEDA casing power tongs, including the KHT9625.


Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit