KT20000 casing tong troubleshooting guide – systematic fault handling. General rules: stop operation on fault, isolate power, tag out. Inspect outside-in, simple-complex, electrical-mechanical. Hydraulic faults: no pressure (low oil, bypass valve open, pump air intake) → refill, close valve, bleed air; low pressure (relief valve, hose leak, filter clog) → reset to 18MPa, tighten fittings, replace filter; overheating (low oil, wrong viscosity, blockage) → cool 30 min, top up, clean cooler; hose bulge/leak → replace with OEM hose. Mechanical: jaw slipping (worn rollers, brake belt gap) → adjust belt, replace rollers; rotation sticking (lack of grease, gear debris) → grease bearings, clean gearbox; safety door not closing (latch sticking, cam wear) → clean, lube, replace cam; pin breakage → replace with OEM pin. Control: torque gauge inaccurate → calibrate or use backup; shift lever stuck → grease shaft, tap gearbox. Torque insufficient → check pressure, adjust brake belt. Emergency: cle
Conatct For Details
DetailReview(0)Additional

Subtitle: Full-Scene Fault Coverage for Hydraulic, Mechanical & Control Systems, Plus Emergency Response Plans


I. General Troubleshooting Principles: Safety First, Scientific Diagnosis

  • Stop operation immediately when a fault occurs: shut down hydraulic pump motor, cut hydraulic supply (close bypass valve), hang "Under Repair – Do Not Operate" tag. Prevent secondary faults or safety incidents.

  • Inspection sequence: Outside → inside, simple → complex, electrical → mechanical. Do not blindly disassemble core components (gearbox, hydraulic pump).

  • Safety rules: Wear PPE during inspection. Do not touch rotating parts or hot hoses. Do not disconnect fittings or open tank before relieving hydraulic pressure.

  • Authority limits: Routine faults (loose fittings, lack of grease) can be handled by field maintenance. Core component faults (broken gear, pump failure) require factory technical support – do not disassemble without authorization.


II. Common Fault Classification & Solutions (Table Format)

(A) Hydraulic System Faults (High Frequency)

FaultPossible CauseStep-by-Step SolutionEmergency Action
Pump runs but no pressure1. Low oil level
2. Bypass valve open
3. Pump air intake
4. Pump wear
1. Top up oil to mark
2. Slowly close bypass valve (watch pressure gauge)
3. Loosen pump bleed valve, expel air, retighten
4. If pump has noise/heat, stop and replace
Top up oil, bleed air, test. If fails, switch to backup pump.
Low hydraulic pressure (≤10 MPa)1. Relief valve set too low
2. Hose leak
3. Filter clogged
4. Wrong oil viscosity
1. Reset relief valve to 18 MPa (calibrate with gauge)
2. Check fittings – tighten or replace seals; replace damaged hose
3. Remove and clean filter (or replace)
4. Replace with manufacturer-recommended oil
Replace with spare filter, tighten fittings, temporarily resume, then overhaul.
Hydraulic overheating (oil >80°C)1. Low oil level
2. Wrong viscosity
3. Line blockage
4. Relief valve sticking
5. Poor cooling
1. Top up oil
2. Replace with correct viscosity (ISO VG46 for high temp, VG32 for low temp)
3. Clean lines, remove blockage
4. Remove relief valve, clean spool, reinstall
5. Clean cooler fins, check cooling fan
Shut down, cool 30 min, top up oil, clean cooler, then test.
Hydraulic hose bulge/leak1. Aging/quality
2. Overpressure
3. Poor connection
4. Twisting/squeezing
1. Immediately replace with OEM hose (no substitutes)
2. Check relief valve, ensure pressure ≤18 MPa
3. Reconnect, ensure full engagement (self-sealing couplers must lock)
4. Reroute hose to avoid twisting
Cut hydraulic supply, replace with spare hose, test for leaks before resuming.

(B) Mechanical Structure Faults (Core Components)

FaultPossible CauseStep-by-Step SolutionEmergency Action
Jaw cannot grip casing (slips/loose)1. Worn/broken jaw rollers
2. Brake belt misadjusted
3. Wrong jaw size for casing
4. Jaw cam surface dry
1. Replace worn/broken rollers; check jaw bolts
2. Tighten brake belt bolt clockwise to reduce gap to ≤0.5 mm
3. Install correct jaw size (7″-20″)
4. Apply grease to cam surface
Temporarily tighten brake belt, add grease. Replace jaw after emergency job.
Tong body rotation sticks / unusual noise1. Insufficient bearing grease
2. Worn/poorly meshed gears
3. Debris in gearbox
4. Shift shaft sticking
1. Grease bearings (focus on idler bearings, roller cup bearings)
2. Open gearbox window, check gears for broken teeth/severe wear; apply gear grease
3. Remove debris from gearbox (depressurize first)
4. Remove shift shaft, clean, grease, reinstall
Grease and test. If still sticking, stop to prevent further gear damage.
Safety door won't close/lock1. Latch sticking
2. Door lock cam worn
3. Debris blocking
4. Lock spring failed
1. Clean latch, apply oil
2. Check cam wear; replace if severe
3. Remove debris from door gaps
4. Replace failed spring (OEM part)
Temporarily clean and lubricate; ensure locked before operation. Replace parts later.
Locating pin broken / difficult to insert/remove1. Pin material fatigue
2. Rust sticking
3. Improper side force during operation
4. Hole deformed
1. Immediately replace with OEM pin (no substitutes)
2. Remove rust, apply anti-rust grease
3. Follow SOP – avoid side loads on pin
4. Minor deformation: file; severe: replace tong body component
Replace with spare pin, apply grease, ensure fully seated before operation.

(C) Control & Display Faults (Operation & Monitoring)

FaultPossible CauseStep-by-Step SolutionEmergency Action
Torque gauge no display / inaccurate1. Poor power contact
2. Calibration失效
3. Load cell failure
4. Loose wiring
1. Check torque gauge power, ensure connections tight
2. Calibrate with calibrated torque wrench; if error >±2%, contact service
3. Check load cell connections, tighten mounting bolts
4. Reconnect plugs, ensure good contact
Switch to backup torque gauge, or use manual torque wrench for monitoring. Calibrate later.
Shift lever stuck (cannot shift)1. Shift shaft dry
2. Shift fork worn
3. Gear stuck
4. Lever deformed
1. Grease shift shaft, gently move lever back and forth
2. Remove clutch inspection plate, check fork for wear
3. Run unit unloaded, tap gearbox side to help unlock
4. Replace deformed lever
Grease and manually assist shift. Avoid brute force. If fails, stop for repair.
Throttle control unresponsive (cannot adjust speed/direction)1. Valve spool sticking
2. Hydraulic oil contaminated
3. Control rod worn
4. Spring failed
1. Remove throttle valve, clean spool, reinstall
2. Replace hydraulic oil and clean filter
3. Check control rod – no wear, secure connection
4. Replace failed spring
Temporarily use spare control valve, or manually adjust bypass valve for speed control.

(D) Operational Performance Faults (Affects Quality/Efficiency)

FaultPossible CauseStep-by-Step SolutionEmergency Action
Insufficient torque output (cannot reach target)1. Low hydraulic pressure
2. Poor jaw grip
3. Low gear transmission efficiency
4. Torque gauge error
1. Check hydraulic system pressure – ensure 18 MPa
2. Adjust brake belt / replace jaws for secure grip
3. Check gear engagement, add grease
4. Calibrate torque gauge
Increase pressure (do not exceed 18 MPa), adjust jaws, test. If still low, stop.
Low casing thread connection pass rate (cross-thread / over-tight)1. Torque control inaccurate
2. Tong not leveled
3. Casing threads contaminated
4. Jaw positioning error
1. Calibrate torque control system
2. Adjust suspension to align tong with casing (tolerance ≤2°)
3. Clean casing threads before operation
4. Check locating pin position, adjust jaw alignment
Clean threads, re-level tong, use manual torque monitoring for critical joints.

III. Emergency Response Summary

Fault CategoryImmediate ActionAfter Stabilization
Hydraulic leakCut hydraulic supply, isolate area, no ignitionReplace hose or seal, test pressure
No rotationCheck pressure, bleed air, inspect pumpReplace pump or valve as needed
Jaw slipTighten brake belt, add greaseReplace worn rollers or jaws
Safety door issueStop operation, manually secure door if possibleRepair lock mechanism
Torque reading abnormalUse backup gauge or manual wrenchCalibrate or replace torque gauge

IV. Contact for Technical Support

For complex faults not resolved by the above, or to order genuine spare parts, contact TEDA technical support:

info@hyrig.com

Provide fault description, photos/videos if possible, and equipment operating hours for faster diagnosis.