The OH2 pump is an overhung, centerline-mounted, single-stage centrifugal pump fully compliant with API 610 11th/12th edition (ISO 13709) standards. The "OH" designation stands for Overhung – meaning the impeller is mounted on the end of a shaft that overhangs its bearing support, with no bearing between the impeller and the shaft end. The "2" suffix specifies a centerline-mounted foot arrangement, which keeps the pump centerline at the same elevation as the mounting feet to accommodate thermal expansion.
This configuration is the most widely used API 610 pump type for general refinery, petrochemical, and industrial process services. OH2 pumps offer a compact footprint, easy access to mechanical seals and bearings, and robust performance across a broad range of temperatures, pressures, and fluid types.
| Parameter | Range |
|---|---|
| Flow rate | Up to 720 m³/h (3,170 gpm) – typical; larger designs available |
| Head | Up to 255 m (837 ft) – single stage; higher with special hydraulics |
| Pressure rating | Up to 6.4 MPa (64 bar / 928 psi) |
| Temperature range | –80°C to +400°C (–112°F to +752°F) |
| Speed | 1,450 / 2,950 rpm (50 Hz) or 1,750 / 3,550 rpm (60 Hz) |
| Maximum casing pressure | Up to 10 MPa (100 bar) for special designs |
| Efficiency | 55% – 85% depending on hydraulic size |
| NPSHr | Optimized per size; inducer available for low NPSHa |
The impeller is mounted at the non-drive end of the shaft, with the bearing housing located immediately behind the impeller. No inboard bearing exists – the shaft is supported only by bearings at the drive end. This simplifies the pump, reduces parts count, and shortens the overall length.
The pump feet are cast integrally with the casing and are positioned on the horizontal centerline of the shaft. This allows the casing to expand uniformly when handling hot fluids, keeping the shaft aligned with the driver and preventing misalignment due to thermal growth.
A heavy-duty, finned bearing housing supports the shaft. Bearings are lubricated by oil bath (standard) or forced oil circulation (optional). Bearing life exceeds API 610 minimum L10 of 25,000 hours. Cooling coils or fins dissipate heat from the bearing housing when handling high-temperature fluids (>150°C).
The shaft is a one-piece forging with generous diameter to minimize deflection. The overhung impeller is keyed, dynamically balanced, and secured with a cap screw and locking washer. Wear rings (replaceable) are fitted on both casing and impeller to preserve clearances and efficiency.
Radially split, single-stage, centerline-mounted casing. Suction and discharge flanges are integral with the casing and face vertically upward (top suction / top discharge) – the standard OH2 nozzle arrangement. This provides easy piping alignment and allows removal of the rotor without disconnecting piping.
Heavy-duty steel baseplate, grouted, with drip lip and drain connection. The driver (electric motor or turbine) mounts on the same baseplate. Coupling is a flexible spacer type, allowing seal and bearing maintenance without moving the driver.
| Component | Carbon Steel (C-6) | 316L SS (S-8) | Duplex (D-1/D-2) |
|---|---|---|---|
| Casing | WCB / LCC | CF3M (316L) | CD4MCu / 2205 |
| Impeller | WCB / LCC | CF3M (316L) | CD4MCu / 2205 |
| Shaft | 4140 / 2Cr13 | 4140 (coated) or 316 SS | Duplex SS |
| Wear rings | Hardened 4140 | 316 SS + Stellite | Duplex + hard facing |
| Gaskets | Spiral wound (graphite filled) | Spiral wound (graphite filled) | Spiral wound / PTFE |
S-8 (316L stainless steel) is the most common selection for corrosive services including amine, sour water, caustic, and many chemical streams. C-6 (carbon steel) is used for clean hydrocarbons, hot oil, and BFW. Duplex (D-1/D-2) is specified for chloride-containing fluids or high H₂S environments with NACE MR0175 compliance.
OH2 pumps are equipped with API 682 mechanical seals. The seal chamber is cast integrally with the casing and sized to accommodate all API 682 seal types (A, B, C) and arrangements (1, 2, 3) without modification.
| Service | Recommended Seal Type | API Plan | Notes |
|---|---|---|---|
| Clean hydrocarbon (diesel, gasoline) | Single cartridge (Type A) | Plan 11 / 21 | Standard self-flush |
| High-temperature oil (>200°C) | Single bellows (Type B) | Plan 21 + cooling | Plan 23 preferred for >250°C |
| Sour water / rich amine | Dual pressurized (Arr. 3) | Plan 53B | H₂S containment |
| Lean amine | Dual or tandem | Plan 52 / 53A | Emission control |
| Hot water / BFW | Single (Type B) with cooling | Plan 23 | Recirculation cooler |
| Caustic / amine | Dual (Arr. 2 or 3) | Plan 52 / 53B | Corrosion resistant faces (SiC/SiC) |
| Industry | Application | Medium Examples |
|---|---|---|
| Refining | Crude transfer, product rundown, reflux | Crude oil, diesel, kerosene, naphtha, gasoline |
| Refining | Amine circulation | Lean amine, rich amine, MDEA, MEA |
| Refining | Sour water | Sour water (H₂S/NH₃) |
| Petrochemical | Chemical feed, transfer | Acids, caustics, solvents, monomers |
| Power generation | Boiler feed booster | BFW, condensate |
| Gas processing | Glycol circulation | TEG, MEG |
| Water / wastewater | Raw water, service water | Fresh water, cooling water |
| Pump Type | Configuration | Best Use | Advantages |
|---|---|---|---|
| OH2 | Overhung, centerline, single stage | General refinery/petrochem duties up to moderate head | Compact, low cost, easy maintenance, thermal stability |
| OH1 | Overhung, foot mounted | Low temperature, clean services | Non-API for many specs; not centerline mounted |
| OH3 | Vertical, in-line, overhung | Space-limited, low NPSH | Vertical mounting |
| OH4 | Rigid coupled, vertical | Small capacity | Compact motor-pump unit |
| BB2 | Between bearings, single stage | High flow, moderate head | Higher flow capacity |
| BB3 | Between bearings, axially split, multistage | High head, high pressure | For head >250 m |
| BB5 | Barrel, radially split, multistage | Very high pressure | Up to 500 bar |
The OH2 pump is the most widely specified API 610 type – it meets the vast majority of refinery and petrochemical pumping requirements (excluding very high head or very high pressure services).
Head-capacity curve: Stable, continuously rising to shut-off – essential for parallel pump operation
Best Efficiency Point (BEP): Typically at 70-90% of rated flow for standard selections
Minimum flow: Usually 25-30% of BEP flow (continuous recirculation or automatic recirculation valve recommended)
NPSHr: Approximately 2-6 m for standard impellers; inducer reduces NPSHr by 40-60%
Back pull-out design – The complete rotating assembly (bearing housing, bearing bracket, shaft, impeller, seal chamber) can be removed from the casing without disconnecting piping.
Spacer coupling – Allows removal of the rotating assembly without moving the driver.
Cartridge mechanical seals – Replaceable as a unit without disassembling the pump.
Replaceable wear rings – Restore hydraulic clearances without replacing the casing or impeller.
Hydrostatic test: 1.5x design pressure
Performance test: Water, at rated speed (Grade 1 or 2)
Mechanical run test: Minimum 4 hours
NPSH test: Optional per specification
Material certification: EN 10204 3.1 (full traceability)
NDE: MPI, dye penetrant, or radiography per API 610
Full API 610 11th/12th edition compliance – design life 20 years, 3-year continuous service
Centerline mounting – maintains alignment during thermal cycling; essential for hot services (>150°C)
Broad hydraulic cover – single pump series covers most refinery duties
Minimum spare parts inventory – common bearing frames and seal chambers across multiple pump sizes
API 682 ready – accepts any seal arrangement without modification
Back pull-out design – reduces maintenance downtime by up to 50%
Material flexibility – carbon steel, 316L SS, duplex, and all API 610 Table H classes
Global installed base – thousands of units in reliable service across refineries, petrochemical plants, and power stations
| Component | Recommended Quantity |
|---|---|
| Mechanical seal cartridge | 1 set per pump |
| Bearing set (radial + thrust) | 1 set |
| Wear ring set (casing + impeller) | 1 set |
| Gasket / O-ring kit | 1 set per pump |
| Shaft (critical units) | 1 per 3 pumps |
For detailed selection of the correct OH2 pump for your process duty – including hydraulic sizing, material selection (C-6, S-8, D-1/D-2), seal plan (API 682), NPSH verification, and complete API 610 data sheet – please contact our engineering team.
Email: info@hyrig.com
*Our engineers support refinery, petrochemical, and industrial projects worldwide with reliable API 610 OH2 pumping solutions for every moderate-head process service.*
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.