This page presents verified field cases of our API 610 OH6 horizontal single-stage overhung pumps with separate baseplate and flexible coupling configuration, operating reliably in variable speed (VFD) applications. Each case demonstrates the pump's ability to adjust flow and head to match changing process demands, saving energy and improving process control.
Case 1 – Refinery Variable Flow Transfer (Middle East)
Background: A refinery needed to transfer crude oil and intermediate products from tank farm to process units with varying feed rates. Fixed-speed pumps required control valves, wasting energy and causing high maintenance on valves and seals.
OH6 Pump Solution:
Flow: 450 m³/h (rated), 180–550 m³/h (operating range)
Head: 95 m (rated), 45–105 m (range)
Speed: 1,200–2,980 rpm (VFD controlled)
Material: Carbon steel casing, 316L impeller
Seal: API 682 Plan 11
Mounting: Foot mounted
Results:
Energy saving – VFD reduced pump speed when demand was low, cutting power consumption by 28%
Stable pressure regulation – no pressure spikes or valve throttling losses
Reduced seal wear – lower speed during low demand extended seal life by 40%
Easy integration – separate baseplate allowed use of plant-standard VFD motors
Available references: Site layout photo, VFD energy saving report, pressure trend log.
Case 2 – Petrochemical Circulation System (Southeast Asia)
Background: A petrochemical plant required a high temperature (310°C) circulation pump for a heat transfer fluid loop. Flow demand varied with reactor load. Fixed-speed pump caused thermal cycling issues and temperature overshoot.
OH6 Pump Solution:
Flow: 220 m³/h (rated), 120–280 m³/h (range)
Head: 85 m
Temperature: 310°C
Material: Carbon steel casing, stainless steel impeller
Seal: API 682 Plan 23 (jacketed)
Mounting: Centerline mounted (for high temperature stability)
VFD: Speed control based on outlet temperature
Results:
Low vibration – centerline mount eliminated thermal misalignment, vibration <2.0 mm/s
Long service life – over 2.5 years continuous operation without bearing or seal replacement
Precise temperature control – VFD adjusted flow to match reactor heat demand, reducing temperature swings
Back pull-out maintenance – scheduled inspection completed in one shift
Available references: Installation photo, vibration log, temperature control chart.
Case 3 – Power Plant Cooling Water (Asia)
Background: A combined cycle power plant needed cooling water pumps for the condenser and auxiliary cooling system. Plant load varied from 40% to 100% depending on grid demand. Fixed-speed pumps wasted energy and required frequent valve adjustment.
OH6 Pump Solution:
Six OH6 pump sets (3× cooling water, 3× auxiliary)
Flow per pump: 650 m³/h (rated), 220–700 m³/h (VFD range)
Head: 32 m
Speed: 800–1,480 rpm (VFD controlled by plant DCS)
Material: Cast iron casing, bronze impeller
Seals: Gland packing (for water service)
Results:
Automatic flow adjustment – pump speed follows plant load signal from DCS, no manual intervention
Energy savings – 32% reduction in cooling water pumping power compared to constant speed + control valve
Reliable operation – all pumps ran 18+ months with zero failures
Low maintenance – back pull-out design allowed bearing inspection without pipe disconnection
Available references: Site layout photo, DCS integration diagram, energy savings calculation.
Case 4 – Chemical Plant Corrosive Medium (Europe)
Background: A chemical plant required a pump for hydrochloric acid transfer from storage to process. Flow rate varied with batch production. The corrosive nature demanded high alloy materials and leak-free sealing.
OH6 Pump Solution:
Flow: 45 m³/h (rated), 15–65 m³/h (VFD range)
Head: 55 m
Temperature: 50°C (ambient)
Material: 316L stainless steel (casing, impeller, shaft)
Seal: API 682 Plan 53B dual mechanical seal (with barrier fluid)
Mounting: Foot mounted
Results:
Leak-free – dual seal with barrier fluid contained hydrochloric acid completely, zero emissions
Low maintenance – VFD reduced speed when not at full flow, lowering wear on seals and bearings
Corrosion resistance – 316L material withstood acid exposure for 2+ years without pitting
Flexible operation – operator adjusts pump speed from control room, no valve throttling
Available references: Site photo, material certificate (EN 10204 3.1), seal performance log.
What You Can Request From Us for Each Case
Site layout photos and installation images
Project parameter sheet (flow, head, speed range, material, seal, mounting)
Performance data (VFD energy savings, vibration logs, temperature control charts)
DCS integration diagrams (where available)
Why Real Project Cases Matter
Field references prove that our OH6 pumps deliver:
Energy savings (20–35% reduction) in variable flow refinery and power plant services (VFD advantage)
Low vibration and long service life in high temperature petrochemical circulation (centerline mount)
Automatic load-following in power plant cooling water systems
Leak-free, low maintenance operation in corrosive chemical service (316L + dual seals)
Get the Complete OH6 Pump Case Study Package
We can match your variable speed application conditions to similar successful installations. Request the OH6 pump project case PDF or ask for references in your specific industry.
Email: info@hyrig.com
Please specify your industry (refinery variable flow / petrochemical high temp / power plant VFD cooling / chemical corrosive) and we will send relevant case studies, site layout photos, and performance data within 24 hours. We also welcome inquiries for custom OH6 VFD pump selection and factory direct pricing.