HYRIG can supply the PARKER CPOM series. These are Manapak sandwich pilot-operated check valves, available in NG6, NG10, and NG16, with single or dual channel configurations.
Conatct For Details
DetailReview(0)Additional

PARKER CPOM Pilot Check Valve Series

Overview:

HYRIG can supply the PARKER CPOM series and related hydraulic components. These sandwich-mounted pilot-operated check valves allow free flow from the valve side to the manifold side and block reverse flow until pilot pressure is applied.

Key Specifications & Model Comparison

Model CodeSizeControlled PortsCracking PressureMax Flow
CPOM2DDNG6A & B1.0 bar54 L/min
CPOM2AANG6A1.0 bar54 L/min
CPOM2BBNG6B1.0 bar54 L/min
CPOM3DDNG10A & B0.8 bar303 L/min
CPOM4DDNG16A & B0.5 barContact factory

Data source: PARKER catalog HY14-2502/US and distributor listings.

For the NG6 dual A&B configuration, view PARKER CPOM2DD. For the NG10 dual A&B configuration, view PARKER CPOM3DD.

Dimensions (Text-Based)

ParameterNG6 (CPOM2)NG10 (CPOM3)NG16 (CPOM4)
Mounting StandardISO 4401-03ISO 4401-05ISO 4401-07
Mounting Bolt Pattern4 × M54 × M64 × M10
Approx. Weight1.8 kg4.0 kg7.4 kg

Cross-Reference & Replacement

AA = A-port lock, BB = B-port lock, DD = dual A&B lock. The control ratio and cracking pressure vary by size. All code positions must match when replacing.

Selection Support

Need to confirm whether single (AA/BB) or dual (DD) locking is required? Contact HYRIG with your circuit details.

Applications

Used for load-holding and pilot-line isolation in hydraulic systems. Common in clamping, mold-locking, and lifting circuits.

Disclaimer: PARKER is a registered trademark of Parker Hannifin Corporation. HYRIG is an independent supplier of hydraulic components and is not affiliated with Parker Hannifin Corporation.

Specifications:

  • Valve Type: Pilot-operated check valve (sandwich plate, hydraulic lock)
  • Sizes: NG6 (CPOM2), NG10 (CPOM3), NG16 (CPOM4)
  • Configurations: AA (A-port), BB (B-port), DD (A&B ports)
  • Maximum Operating Pressure: 350 bar (CPOM2/3); 210 bar (CPOM6, if applicable)
  • Cracking Pressure: CPOM2: 1.0 bar; CPOM3: 0.8 bar; CPOM4: 0.5 bar
  • Control Ratio: 1:3 or 1:7 (CPOM2); 1:3 or 1:6.5 (CPOM3); 1:2.4 (CPOM4)