PARKER CPOM Pilot Check Valve Series
Overview:
HYRIG can supply the PARKER CPOM series and related hydraulic components. These sandwich-mounted pilot-operated check valves allow free flow from the valve side to the manifold side and block reverse flow until pilot pressure is applied.
| Model Code | Size | Controlled Ports | Cracking Pressure | Max Flow |
|---|---|---|---|---|
| CPOM2DD | NG6 | A & B | 1.0 bar | 54 L/min |
| CPOM2AA | NG6 | A | 1.0 bar | 54 L/min |
| CPOM2BB | NG6 | B | 1.0 bar | 54 L/min |
| CPOM3DD | NG10 | A & B | 0.8 bar | 303 L/min |
| CPOM4DD | NG16 | A & B | 0.5 bar | Contact factory |
Data source: PARKER catalog HY14-2502/US and distributor listings.
For the NG6 dual A&B configuration, view PARKER CPOM2DD. For the NG10 dual A&B configuration, view PARKER CPOM3DD.
| Parameter | NG6 (CPOM2) | NG10 (CPOM3) | NG16 (CPOM4) |
|---|---|---|---|
| Mounting Standard | ISO 4401-03 | ISO 4401-05 | ISO 4401-07 |
| Mounting Bolt Pattern | 4 × M5 | 4 × M6 | 4 × M10 |
| Approx. Weight | 1.8 kg | 4.0 kg | 7.4 kg |
AA = A-port lock, BB = B-port lock, DD = dual A&B lock. The control ratio and cracking pressure vary by size. All code positions must match when replacing.
Need to confirm whether single (AA/BB) or dual (DD) locking is required? Contact HYRIG with your circuit details.
Used for load-holding and pilot-line isolation in hydraulic systems. Common in clamping, mold-locking, and lifting circuits.
Disclaimer: PARKER is a registered trademark of Parker Hannifin Corporation. HYRIG is an independent supplier of hydraulic components and is not affiliated with Parker Hannifin Corporation.
Specifications:
Contact Us:
For PARKER CPOM series selection, contact HYRIG: info@hyrig.com
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.