HYRIG can supply blind seal ram assemblies and replacement sealing components for the 5 1/8″ 15,000 psi Quad BOP.
Conatct For Details
DetailReview(0)Additional

Key Facts

  • Ram position: top set of the quad BOP stack
  • Function: full wellbore seal when no tubing is present
  • Working pressure: 15,000 psi
  • Service: H2S, NACE MR0175
  • Seal arrangement: outer seal and inner seal
  • Ram body: reusable after inspection
  • Equalizer: required at sealing ram positions
  • Data source: Technical data and parts list

Blind Seal Ram Specifications & Component Breakdown

ComponentFunctionReplacement guidance
Ram bodyMain structure and seal housingReuse after inspection; replace if sealing surface is pitted or gouged
Outer sealPrimary wellbore isolationWear component; replace when cuts or cracks appear
Inner sealSecondary sealing around ram bodyWear component; replace with outer seal as a set
Retaining screwsSecure inner sealCheck torque and thread condition

Dimensions

ParameterValue
BOP vertical bore5 1/8″
Working pressure15,000 psi max
Temperature range-20°F to +250°F
Top connection15K BX-169 studded flange
Bottom connection15K BX-169 open flange

Structure / Working Principle

The blind seal ram closes across an empty wellbore. The outer seal contacts the BOP cavity sealing surface, while the inner seal provides a secondary barrier around the ram body. Both seals must be installed in the correct orientation, and the inner seal is secured by screws. Pressure must be equalized before opening; otherwise the sealing rams can be damaged by a pressure surge.

Cross-Reference & Replacement

Looking to replace blind ram seals or a complete blind ram assembly? Check ram position, seal orientation, equalizer compatibility and the seal ram drawing reference. HYRIG supplies replacement parts including outer seals, inner seals and retaining screws. The ram body is typically reused after inspection. See 5 1/8″ 15K Quad BOP and Quad BOP Parts.

Applications

  • Top isolation when coiled tubing is out of the hole
  • Emergency shut-in after shear operations
  • Workover and completion with no tubing present
  • Pressure testing with equalizer operation

Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.

Selection Support

Send the ram drawing reference 1117435-XXX and BOP serial number to confirm the blind ram seal part number and replacement scope.

Frequently Asked Questions

Q: What is the difference between blind and pipe seal rams?
A: The blind ram seals an empty wellbore; the pipe ram seals around tubing.

Q: Can blind ram seals be replaced without replacing the ram body?
A: Yes. Outer seal, inner seal and screws are wear components; inspect the ram body before reuse.

Q: Why must pressure be equalized before opening blind rams?
A: Opening with a pressure differential can cause a surge that damages ram or hydraulic assemblies.

Q: Is the blind seal ram suitable for H2S service?
A: Yes. The quad BOP is rated for H2S service up to 15,000 psi working pressure.

Q: Is this an OEM catalog page?
A: No. This page describes the configuration and parts documented in the operation and maintenance manual.

Contact

For blind seal ram selection and replacement parts, contact HYRIG: info@hyrig.com

Related Pages

Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit