| Component | Function | Replacement guidance |
|---|---|---|
| Ram body | Main structure and seal housing | Reuse after inspection; replace if sealing surface is pitted or gouged |
| Outer seal | Primary wellbore isolation | Wear component; replace when cuts or cracks appear |
| Inner seal | Secondary sealing around ram body | Wear component; replace with outer seal as a set |
| Retaining screws | Secure inner seal | Check torque and thread condition |
| Parameter | Value |
|---|---|
| BOP vertical bore | 5 1/8″ |
| Working pressure | 15,000 psi max |
| Temperature range | -20°F to +250°F |
| Top connection | 15K BX-169 studded flange |
| Bottom connection | 15K BX-169 open flange |
The blind seal ram closes across an empty wellbore. The outer seal contacts the BOP cavity sealing surface, while the inner seal provides a secondary barrier around the ram body. Both seals must be installed in the correct orientation, and the inner seal is secured by screws. Pressure must be equalized before opening; otherwise the sealing rams can be damaged by a pressure surge.
Looking to replace blind ram seals or a complete blind ram assembly? Check ram position, seal orientation, equalizer compatibility and the seal ram drawing reference. HYRIG supplies replacement parts including outer seals, inner seals and retaining screws. The ram body is typically reused after inspection. See 5 1/8″ 15K Quad BOP and Quad BOP Parts.
Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.
Send the ram drawing reference 1117435-XXX and BOP serial number to confirm the blind ram seal part number and replacement scope.
Q: What is the difference between blind and pipe seal rams?
A: The blind ram seals an empty wellbore; the pipe ram seals around tubing.
Q: Can blind ram seals be replaced without replacing the ram body?
A: Yes. Outer seal, inner seal and screws are wear components; inspect the ram body before reuse.
Q: Why must pressure be equalized before opening blind rams?
A: Opening with a pressure differential can cause a surge that damages ram or hydraulic assemblies.
Q: Is the blind seal ram suitable for H2S service?
A: Yes. The quad BOP is rated for H2S service up to 15,000 psi working pressure.
Q: Is this an OEM catalog page?
A: No. This page describes the configuration and parts documented in the operation and maintenance manual.
For blind seal ram selection and replacement parts, contact HYRIG: info@hyrig.com
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.