| Parameter | 5 1/8″ 15K Quad BOP |
|---|---|
| Working pressure | 15,000 psi max |
| Operating vertical bore | 5 1/8″ |
| Hydraulic operating pressure | 2,200 psi; 3,000 psi max |
| Injection port | 15K BX-152 studded flange |
| Regular closing volume | 249 in3 per set |
| Regular opening volume | 265 in3 per set |
| Shear closing volume | 367 in3 per set |
| Shear opening volume | 367 in3 per set |
| Hydraulic connections | 1/2″ NPT |
| Item | Value |
|---|---|
| Top connection | 15K BX-169 studded flange |
| Bottom connection | 15K BX-169 open flange |
| Injection port | 15K BX-152 studded flange |
| Hydraulic port | 1/2″ NPT |
The quad BOP uses four ram sets in one body. The top blind set seals an empty wellbore; the second shear set cuts tubing; the third slip set holds tubing; the bottom pipe set seals around tubing. Actuators are hydraulic, with manual auxiliary stems for mechanical lock or manual closure if hydraulic power is lost. See Blind Seal Ram Assembly and Shear Ram Assembly for configuration details.
When reviewing a quad BOP configuration, confirm ram order, equalizer location, actuator type and flange connection. Sealing ram positions must use equalizer assemblies. Shear and slip positions use blanked equalizer ports in the standard configuration. Replacement seals and wear parts are listed on Quad BOP Parts.
Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.
Confirm ram arrangement, tubing size, H2S service and equalizer port locations before ordering. HYRIG can review the BOP serial number and ram drawing references to match replacement parts.
HYRIG supplies replacement parts for the 5 1/8″ 15K Quad BOP, including seal kits, equalizer needle valves and ram seals. See Quad BOP Parts.
Q: What ram sets are in the 5 1/8″ 15K Quad BOP?
A: The standard stack has blind, shear, slip and pipe ram sets, from top to bottom.
Q: What is the working pressure?
A: The quad BOP is rated for 15,000 psi maximum working pressure in H2S service.
Q: Can the rams be opened without hydraulic pressure?
A: No. The rams open hydraulically; manual stems are for locking or manual closure, not hydraulic opening.
Q: Are manual locks used for shearing?
A: No. Manual locks are not intended for shearing applications.
Q: Why must pressure be equalized before opening sealing rams?
A: Equalization prevents a pressure surge that can damage ram or hydraulic assemblies.
For 5 1/8″ 15K Quad BOP selection and spare parts, contact HYRIG: info@hyrig.com
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.