| Component | Function | Replacement guidance |
|---|---|---|
| Shear ram body | Carries blade and interfaces with actuator | Inspect for deformation and sealing surface damage |
| Shear blade | Cuts tubing | Replace when cutting edge is worn or chipped |
| Blade screws | Secure blade to ram | Tighten to 45 ft.lbs; replace if damaged |
| Shear actuator | Provides high closing ratio | Verify closing ratio and seal condition |
| Parameter | Value |
|---|---|
| BOP vertical bore | 5 1/8″ |
| Working pressure | 15,000 psi max |
| Temperature range | -20°F to +250°F |
| Shear closing volume | 367 in3 per set |
| Shear opening volume | 367 in3 per set |
The shear ram closes with a dedicated shear actuator to cut tubing. The blade is mounted to the ram body and secured by screws tightened to 45 ft.lbs. After shearing, the blind ram above can seal the wellbore. Manual locks are not intended for shearing applications, and pressure must be equalized before opening sealing rams.
Looking to replace shear blades or a shear ram assembly? Check ram position, blade part number, screw torque and actuator type. HYRIG supplies replacement shear blades and related wear parts. See 5 1/8″ 15K Quad BOP and Quad BOP Parts.
Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.
Confirm tubing size, blade part number and actuator type before ordering. Send the BOP serial number and shear ram drawing reference for matching.
Q: What is the shear actuator closing ratio?
A: The shear actuator closing ratio is 19.25:1.
Q: What torque is used for shear blade screws?
A: Shear blade screws are tightened to 45 ft.lbs.
Q: Can manual locks be used for shearing?
A: No. Manual locks are not intended for shearing applications.
Q: Can shear blades be replaced separately?
A: Yes. Shear blades are wear components and can be replaced separately from the ram body.
Q: Is this an OEM catalog page?
A: No. It describes the configuration and parts documented in the operation and maintenance manual.
For shear ram selection and replacement blades, contact HYRIG: info@hyrig.com
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.