| Parameter | Value |
|---|---|
| Working pressure | 15,000 psi max |
| Service | H2S |
| Equalizer valve | Needle valve |
| Valve adjustment | 5/16″ allen wrench |
| Capscrew torque | 30 ft.lbs max |
| Blanked ports | Shear and slip positions in standard configuration |
| Item | Value |
|---|---|
| Flange type | 15K flanged equalizing system |
| Capscrew torque | 30 ft.lbs max |
| Needle valve seat | Thread in until seated; do not over-torque |
Each sealing ram assembly uses a single-point equalizing system. Partially unthreading the needle valve opens a path from below the ram to above the ram, equalizing pressure. During normal operation, thread the needle valve in until it seats to block the path. The equalizer assembly must be used with sealing rams. Shear and slip ram equalizer ports are blanked off in the standard configuration.
Looking to replace an equalizer needle valve or equalizer assembly? Check flange type, needle valve part number and sealing ram position. See 5 1/8″ 15K Quad BOP, Quad BOP Parts and Pipe Seal Ram Assembly.
Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.
Confirm equalizer port location, sealing ram configuration and needle valve part number before ordering. HYRIG can review the BOP serial number and equalizer drawing reference.
Q: Why must pressure be equalized before opening rams?
A: Equalization prevents a pressure surge that can damage ram or hydraulic assemblies.
Q: How is the equalizer needle valve operated?
A: Partially unthread the needle valve with a 5/16″ allen wrench to equalize pressure.
Q: Which ram positions use equalizer assemblies?
A: Sealing ram positions use equalizer assemblies; shear and slip ports are blanked in the standard configuration.
Q: What torque is used for equalizer capscrews?
A: Equalizer capscrews are tightened to 30 ft.lbs maximum.
Q: Is this an OEM catalog page?
A: No. It describes equalizer operation documented in the operation and maintenance manual.
For 5 1/8″ 15K Quad BOP equalizer selection and replacement valves, contact HYRIG: info@hyrig.com