| Cause | Solution |
|---|---|
| Air in the suction line | Check pipe connections, bleed the pump, ensure the tank level is sufficient. |
| High oil viscosity | Use the recommended viscosity oil or warm up the system. |
| Suction pipe diameter too small | Increase the pipe diameter to reduce pressure drop. |
| Pump mechanical damage (e.g., bearing) | Contact the service team for repair/replacement. |
| Cause | Solution |
|---|---|
| Wrong rotation direction | Check the drive motor rotation and change if necessary. |
| Air in the system | Bleed the pump and the entire hydraulic circuit. |
| Pump worn out | Check internal leakage; replace the pump if wear is excessive. |
| Suction line blocked | Clean the suction filter and pipes. |
| Cause | Solution |
|---|---|
| Pressure valve setting too low | Adjust the relief valve or pressure control valve. |
| Internal leakage (wear) | Check the case drain flow; if it exceeds the limit, the pump/motor needs repair. |
| Drive power insufficient | Check the electric motor or engine output. |
| Cause | Solution |
|---|---|
| Incorrect oil viscosity | Use the recommended oil grade (e.g., VG46 or VG68). |
| Continuous operation at peak pressure | Review the duty cycle; consider a larger displacement or cooling system. |
| Cooling system failure | Check the oil cooler and fan. |
| Case drain blocked | Ensure the case drain line is unobstructed and returns to the tank below the oil level. |
Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.
Suspect a component failure? Explore our A2FO Pumps or contact our engineers for a diagnostic review.
Q: My hydraulic pump is very noisy. Where should I start?
A: Start by checking the suction line for air leaks and ensuring the oil level is correct. Also verify the oil viscosity and the suction pressure.
Q: Why is the flow rate lower than expected?
A: Check if the drive speed is correct. If the pump is worn, internal leakage can reduce the effective flow. Measure the case drain flow to assess wear.
Q: What causes the pump to overheat?
A: Overheating can be caused by operating at peak pressure for too long, using oil with high viscosity, or a failure in the cooling system. Ensure the case drain is not restricted.
For troubleshooting support, contact HYRIG: info@hyrig.com