HYRIG can supply Casappa PLP and PLM series gear pumps and motors. This guide explains the Casappa model code structure for ordering: type, rotation, version, drive shaft, mounting flange, ports, seals, and options.
| Parameter | Value |
|---|---|
| Applicable series | PLP 10, PLP 20, PLP 30, PLM 10, PLM 20, PLM 30 |
| Code fields | 13 positions (PLP) / 10-11 positions (PLM) |
| Rotation codes | S, D, R, L, B |
| Shaft codes | 81, 82, 83, 84, 86, 54, 55, 56, 46, 41, 03, 01, 02, 04, 05, 31, 32, 33, 12, A8, A5, 29, 30, 36, 95, B1, 48 |
| Flange codes | E1–E8, B1–B6, K2, S0–S9, R8, R9, W8, W9, U3 |
| Port codes | BB/BA, BE/BC, EA/EB, MA/MB, SA/SB, GC/GD/GE/GF/GG/GH, OA/OB/OC/OD/OF/OG/OH |
| Seal codes | N (Buna N), V (Viton) |
| Shaft seal codes | D (standard), H (high pressure), C (high pressure + wiper) |
PLP10 - 6.3 - L 0 81 E1 - L - BB/BA - N EL C L - GA - FS
1 2 3 4 5 6 7 8 9 10 11 12 13| Position | Field | Options |
|---|---|---|
| 1 | Type | PLP 10-1, PLP 10-1.5, PLP 10-2, PLP 10-2.5, PLP 10-3.15, PLP 10-4, PLP 10-5, PLP 10-5.8, PLP 10-6.3, PLP 10-8, PLP 10-10 |
| 2 | Rotation | S (left), D (right), R (reversible rear external drain), L (reversible side external drain), B (reversible internal drain) |
| 3 | Version | 0 (without outboard bearing) |
| 4 | Drive shaft | 81, 86, 02, 30, 36, 29 |
| 5 | Mounting flange | E1, E7, E8, B1, K2, S0, R9, R8, W9 |
| 6 | Ports position | L (side), P (rear) |
| 7 | Ports IN/OUT | BB/BA, GC/GC, OB/OA |
| 8 | Seals | N (Buna N), V (Viton) |
| 9 | Cover options | (blank) = cast iron, E = aluminum flange + cast iron rear, L = cast iron flange + aluminum rear, EL = aluminum flange + rear |
| 10 | Shaft seal | D (standard wiper), H (high pressure), C (high pressure + wiper) |
| 11 | Drain port position | (blank) = side, L = side drain with side port, * = side drain with bottom port |
| 12 | Drain port | GA (PLP 10-1 to 10-3.15), others |
| 13 | Shaft arrangement | FS (female spline) |
PLP20 - 14 - L 0 82 E2 - L - EA/EA - N EL C L - TA - FS
1 2 3 4 5 6 7 8 9 10 11 12 13| Position | Field | Options |
|---|---|---|
| 1 | Type | PLP 20-4 to PLP 20-31.5 (15 displacements) |
| 2 | Rotation | S, D, R, L, B |
| 3 | Version | 0 (without outboard bearing), W8, 4, 5, 6, 7, 8, 9 (with outboard bearing) |
| 4 | Drive shaft | 82, 54, 55, 46, 03, 01, 31, 04, 32, 12, 48, B1, 95 |
| 5 | Mounting flange | E2, B2, B4, B5, B6, S1, S2, S9, S5, W8 |
| 6 | Ports position | L (side), P (rear) |
| 7 | Ports IN/OUT | BE/BC, EA/EA, MA/MA, SA/SA, GD/GD, OC/OC |
| 8 | Seals | N, V |
| 9 | Cover options | (blank), E, L, EL |
| 10 | Shaft seal | D, H, C |
| 11 | Drain port position | (blank), L, * |
| 12 | Drain port | TA, GB, 03 |
| 13 | Shaft arrangement | FS (female spline) |
PLM30 - 34 - L 0 83 E3 - L - ED/EB - N C - FS
1 2 3 4 5 6 7 8 9 10 11| Position | Field | Options |
|---|---|---|
| 1 | Type | PLM 30-22 to PLM 30-90 (10 displacements) |
| 2 | Rotation | S, D, R |
| 3 | Version | 0 (without outboard bearing) |
| 4 | Drive shaft | 83, 84, 56, 41, A8, A5, 04, 05, 32, 33 |
| 5 | Mounting flange | E3, E4, B3, S5, U3 |
| 6 | Ports position | L (side) |
| 7 | Ports IN/OUT | BM/BL, ED/EB, MB/MA, SB/SA, GF/GF, OF/OD |
| 8 | Seals | N, V |
| 9 | Shaft seal | D, H, C |
| 10 | Shaft arrangement | FS (female spline) |
Data source: Technical data table
| Code | Description |
|---|---|
| S | Left-hand rotation (anti-clockwise looking at drive shaft) |
| D | Right-hand rotation (clockwise looking at drive shaft) |
| R | Reversible with rear external drain |
| L | Reversible with side external drain |
| B | Reversible with internal drain |
| Code | Description | Max Pressure |
|---|---|---|
| D | Standard seal with wiper | 3 bar (44 psi) |
| H | High pressure seal | 25 bar (363 psi) |
| C | High pressure seal with wiper | 25 bar (363 psi) |
Not sure how to build your Casappa model code? Send HYRIG your required displacement, rotation, mounting flange, shaft type, port connections, and seal preference. Our engineers will confirm the complete model code.
Q: What does the first number after PLP mean?
A: The first number indicates the group size: PLP 10 (compact), PLP 20 (medium), PLP 30 (large). Group size determines displacement range and mounting dimensions.
Q: What does the R suffix mean in the model code?
A: R indicates reversible rotation with external drain. Other options: S (left-hand), D (right-hand), L (reversible side external drain), B (reversible internal drain).
Q: How do I specify the mounting flange?
A: Use the flange code: E1–E8 (European), B1–B6 (German), K2 (German 4-bolt), S0–S9 (SAE), R8/R9 (SAE 2-4 bolt), W8/W9 (SAE/German), U3 (SAE B 2-bolt).
Q: What seal options are available?
A: N (Buna N standard) and V (Viton for high temperature). Shaft seal options: D (standard wiper), H (high pressure), C (high pressure + wiper).
Q: What is the lead time for a custom-configured Casappa pump?
A: Standard lead time is 4–6 weeks for most configurations. Urgent downtime situations can be prioritized.
Q: Can HYRIG help me confirm the correct model code?
A: Yes. Send us your nameplate details or system requirements, and our engineers will confirm the complete model code and configuration.
For Casappa model code assistance, contact HYRIG: info@hyrig.com
Explore: Casappa PLP 10 Gear Pumps, Casappa PLP 20 Gear Pumps, Casappa PLP 30 Gear Pumps, Casappa PLM 10 Gear Motors, Casappa PLM 20 Gear Motors, Casappa PLM 30 Gear Motors.