| Size | Displacement (cc/rev) | Nominal Pressure (bar) | Max Flow (L/min) | Max Speed (rpm) | Weight (kg) | Flange | Ports |
|---|---|---|---|---|---|---|---|
| 5 | 4.93 | 315 | 27.6 | 5,600 | 2.5 | ISO 3019-2 | DIN 3852 / SAE |
| 10 | 10.3 | 400 | 32 | 3,150 | 6.0 | ISO 3019-2 | DIN 3852 / SAE |
| 12 | 12 | 400 | 38 | 3,150 | 6.0 | ISO 3019-2 | DIN 3852 / SAE |
| 16 | 16 | 400 | 50 | 3,150 | 6.0 | ISO 3019-2 | DIN 3852 / SAE |
| 23 | 22.9 | 400 | 57 | 2,500 | 9.5 | ISO 3019-2 | DIN 3852 / SAE |
| 28 | 28.1 | 400 | 70 | 2,500 | 9.5 | ISO 3019-2 | DIN 3852 / SAE |
| 32 | 32 | 400 | 80 | 2,500 | 9.5 | ISO 3019-2 | DIN 3852 / SAE |
| 45 | 45.6 | 400 | 114 | 2,500 | 13.5 | ISO 3019-2 | DIN 3852 / SAE |
| 56 | 56.1 | 400 | 126 | 2,240 | 18.0 | ISO 3019-2 | DIN 3852 / SAE |
| 63 | 63 | 400 | 126 | 2,000 | 18.0 | ISO 3019-2 | DIN 3852 / SAE |
| 80 | 80.4 | 400 | 145 | 2,000 | 23.0 | ISO 3019-2 | DIN 3852 / SAE |
| 90 | 90 | 400 | 145 | 1,800 | 23.0 | ISO 3019-2 | DIN 3852 / SAE |
| 107 | 106.7 | 400 | 171 | 1,800 | 32.0 | ISO 3019-2 | DIN 3852 / SAE |
| 125 | 125 | 400 | 200 | 1,600 | 32.0 | ISO 3019-2 | DIN 3852 / SAE |
| 160 | 160.4 | 400 | 233 | 1,600 | 45.0 | ISO 3019-2 | SAE Flange |
| 180 | 180 | 400 | 261 | 1,450 | 45.0 | ISO 3019-2 | SAE Flange |
| 200 | 200 | 400 | 310 | 1,450 | 66.0 | ISO 3019-2 | SAE Flange |
| 250 | 250 | 350 | 375 | 1,500 | 73.0 | ISO 3019-2 | SAE Flange |
| 355 | 355 | 350 | 469 | 1,500 | 110.0 | ISO 3019-2 | SAE Flange |
| 500 | 500 | 350 | 600 | 1,200 | 155.0 | ISO 3019-2 | SAE Flange |
Data source: Technical data table.
The A2FO pump operates on the bent-axis principle. The cylinder block rotates with the drive shaft, and the pistons are angled relative to the shaft. As the shaft turns, the pistons reciprocate inside the cylinder bores, drawing oil from the suction port and pushing it out through the pressure port.
Used in hydrostatic drives for mobile and industrial applications:
Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.
Need help selecting the correct displacement or shaft type? Explore specific models: A2FO10 Pump or contact our engineers with your system specifications.
Q: What is the maximum pressure for the A2FO series?
A: For sizes 10 to 200, the nominal pressure is 400 bar with a peak of 450 bar. Sizes 5, 250, 355, and 500 have slightly lower ratings.
Q: Does the pump require a case drain?
A: Yes, the case drain (T port) must be connected to the tank to ensure proper lubrication and prevent seal damage.
Q: Can the rotation direction be changed?
A: The pump is designed for either clockwise or counter-clockwise rotation (specified at order). It cannot be reversed during operation.
For A2FO series pump selection and spare parts, contact HYRIG: info@hyrig.com
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.