An amine circulation pump is a critical component in gas sweetening units (amine treating) used to remove H₂S and CO₂ from natural gas, refinery fuel gas, and other hydrocarbon streams. The pump handles either lean amine (regenerated, low H₂S/CO₂) or rich amine (loaded with acid gases). Amine solutions (DEA, MEA, MDEA, etc.) are corrosive, can degrade with oxygen ingress, and often require low net positive suction head (NPSH). Our API 610 OH2 centrifugal pump is specifically engineered for reliable, long‑life amine circulation duty. This design fully complies with API 610 11th/12th edition (ISO 13709) .
Structure match check: API 610 OH2 is defined as a horizontal, single‑stage, overhung pump with foot‑mounted casing and back pull‑out design. This matches amine circulation requirements because:
OH2 provides easy maintenance – back pull‑out for seal, impeller, bearing inspection without disturbing piping.
Corrosion resistant materials (stainless steel, duplex) are readily available in OH2 design.
Low NPSH can be achieved with inducer or high‑suction specific speed impeller – critical for rich amine from flash drums.
Centerline support (for lower temperature amine) is foot‑mounted; higher temperature units (up to 120°C) may use centerline support.
Why API 610 OH2 for amine circulation duty?
Corrosion resistance – Amines are corrosive, especially when degraded or with H₂S/CO₂ in solution. Wetted parts available in 316SS, 904L, duplex (2205, 2507), or Alloy 20. Standard carbon steel is not recommended.
Low NPSH capability – Rich amine entering from flash drum often has NPSHa below 3 m. Optional inducer reduces NPSHr to as low as 0.5 m, preventing cavitation and amine degradation.
Good sealing – API 682 mechanical seals with Plan 11 (internal recirculation) or Plan 52/53A for zero emissions. Plan 32 (external clean flush) may be used to keep seal faces clean. For hot amine, Plan 23 (cooled recirculation) prevents coking.
Low oxygen ingress – Amine is oxygen‑sensitive (oxidation causes degradation). Proper seal design with double seals and barrier fluid prevents air ingress.
High efficiency – Amine pumps run continuously (24/7/365). CFD‑optimized impeller reduces power consumption, saving energy.
Wide hydraulic range – Flow from 10 to 2500 m³/h, head up to 250 m, covering typical amine circulation rates.
Temperature range – Ambient to 120°C (lean amine regenerator discharge).
Key design features for amine service
Materials – Casing: 316SS (CF8M), 317L, or duplex. Impeller / shaft: 316SS, duplex, or Alloy 20. Wear rings: hardened 17-4PH or Stellite. Gaskets: PTFE or spiral wound with PTFE filler.
NPSH improvement – Inducer option standard. Alternatively, larger impeller eye diameter reduces NPSHr.
Sealing – Cartridge single seal (Plan 11) for non‑hazardous. Double or tandem seals with Plan 52/53A for emission control (increasingly required). Seal face materials: SiC vs. carbon, or SiC vs. SiC for abrasive amine with particulates (e.g., iron sulfide).
Impeller – Closed, radially balanced. Trim to exact duty point.
Bearings – Anti‑friction, oil lubricated. For hot amine (>80°C), cooling fan or water jacket on bearing housing. Pure oil mist optional.
Vent and drain – 1/2" NPT connections on casing top and bottom for complete draining and venting.
Flush plans – Plan 11 standard. Plan 13 (suction recirculation) for horizontal seal chamber. Plan 32 with clean water/amine external flush to protect seal from degraded amine or solids.
Typical performance range
| Parameter | Value |
|---|---|
| Flow rate | 10 – 2500 m³/h |
| Head | Up to 250 m |
| Temperature | Up to 120°C |
| Pressure rating | Up to 25 bar |
| NPSHr (with inducer) | As low as 0.5 m |
| Speeds | 1450 / 2900 / 3600 rpm |
Typical applications
Lean amine pump – from regenerator (stripper) to absorber (high pressure).
Rich amine pump – from flash drum to regenerator (lower head).
Amine make‑up pump – transfer fresh amine to storage or feed.
Semi‑lean amine pump – in split‑flow configurations.
Amine circulation in refineries, gas plants (NG), LNG facilities, and petrochemical CO₂ removal (e.g., ammonia plants).
Why choose our API 610 OH2 amine circulation pump?
Full API 610 compliance – Performance test, mechanical run test, NPSH test (with inducer if specified).
Corrosion resistant materials – Full stainless steel or duplex construction ensures long life in aggressive amine service.
Low NPSH – Inducer prevents cavitation which degrades amine and damages pump.
Low life cycle cost – Energy efficient hydraulics + long seal life + easy maintenance.
Short lead time – Standard 316SS pumps ex‑stock; duplex / special alloys 8‑10 weeks.
Global spare parts support – Impellers, shafts, seals, bearings, casings shipped worldwide.
Experience – We supply amine pumps to refineries, gas plants, and petrochemical facilities globally.
Quality assurance
ISO 9001:2015 certified.
API 610 mechanical run test (minimum 4 hours) with vibration and bearing temperature monitoring.
NPSH test verification (with inducer if ordered).
Hydrostatic test of casing.
Material traceability EN 10204 3.1 (3.2 on request).
PMI (positive material identification) as standard for alloy construction.
NDE – MT, PT, UT as required.
How to specify your amine circulation pump
Please provide: flow (m³/h), head (m), operating temperature (°C), NPSHa (m), amine type (DEA, MEA, MDEA, etc.), concentration, whether lean or rich amine (corrosive level, solids like iron sulfide), H₂S content in gas (for material selection), required material (316SS, duplex, etc.), and emission regulations (if zero leakage seals needed). We will recommend impeller size, inducer (yes/no), seal type and flush plan, material class, and driver details.
Contact us
For a quotation or technical discussion on amine circulation pumps (API 610 OH2) :
info@hyrig.com
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.