Lean Amine Pump | API 610 OH2 Centrifugal Pump | China OH2 Pump Manufacturer

QR code
share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
copy Link
Facebook
X
LinkedIn
Pinterest
Line
Tumblr
API 610 OH2 single‑stage, overhung pump for lean amine (regenerated amine) circulation from stripper to absorber. Corrosion resistant stainless steel or duplex. Handles up to 120°C, low NPSH available. Continuous duty. China OH2 pump manufacturer.

Conatct For Details
DetailReview(0)Additional

A lean amine pump circulates regenerated amine solution (typically DEA, MEA, MDEA) from the stripper (regenerator) back to the absorber in gas sweetening units. Lean amine is nearly free of H₂S and CO₂ but is hot (typically 100-120°C), corrosive, and can contain degradation products. The pump operates continuously at relatively high pressure (to match absorber pressure). Our API 610 OH2 centrifugal pump is specifically engineered for lean amine service. This design fully complies with API 610 11th/12th edition (ISO 13709) .

Structure match check: API 610 OH2 is defined as a horizontal, single‑stage, overhung pump with foot‑mounted casing and back pull‑out design. This matches lean amine requirements because:

  • OH2 provides easy maintenance – back pull‑out for seal, impeller, bearing inspection without disturbing piping, essential for high‑availability continuous service.

  • Corrosion resistant materials (stainless steel, duplex) are standard in OH2 construction.

  • High temperature capability (up to 120°C) is accommodated by proper material selection and optional cooling on bearing housing.

  • Low NPSH – Lean amine may have limited NPSHa from stripper bottom. Inducer option solves this.

  • Centerline support is not required at 120°C but can be provided for future expansion or higher temps.

Why API 610 OH2 for lean amine duty?

  • Corrosion resistance – Lean amine is less aggressive than rich amine but still corrosive, especially if degraded. Wetted parts in 316SS, 317L, 904L, or duplex (2205/2507). Carbon steel is not acceptable for long life.

  • High temperature operation – Lean amine leaves the regenerator at 100-120°C. Materials chosen for this range. Bearing housing may require cooling fan or water jacket if ambient is high.

  • Low NPSH capability – Stripper bottoms often run at low headroom. Optional inducer reduces NPSHr below 1 m, preventing cavitation and amine degradation.

  • High efficiency – Lean amine pumps run 24/7/365. CFD‑optimized hydraulics reduce energy consumption – significant long‑term saving.

  • Sealing – API 682 Plan 11 (internal recirculation) is standard for clean lean amine. Plan 23 (cooled recirculation) for hotter lean amine. Plan 53A / double seals for zero emissions where required.

  • Flow range – 10 to 2500 m³/h, head up to 250 m. Typical lean amine heads are often higher than rich amine due to absorber pressure.

Key design features for lean amine service

  • Materials – Casing: CF8M (316SS), CF3M (316L), CD4MCu (duplex), or Alloy 20. Impeller / shaft: 316SS, duplex, or 17-4PH. Wear rings: 17-4PH H1150 or Stellite. Gaskets: PTFE / spiral wound with PTFE.

  • Vent and drain – Full vent at casing high point; full drain at low point. For lean amine, need to prevent air ingress (oxygen degrades amine).

  • Inducer – Recommended if NPSHa is below 3 m.

  • Impeller – Closed, radially balanced, trimmed to exact duty point. For larger flows, double‑suction first stage optional to reduce NPSHr and balance thrust.

  • Sealing – Cartridge mechanical seals. Face materials: Silicon carbide vs. carbon (standard). For abrasive amine (iron sulfide particles), SiC vs. SiC. Plan 11 (internal recirculation) typical. For hot lean amine (>100°C), Plan 23 (cooled recirculation) extends seal life. For environmental compliance, double or tandem seals with Plan 52/53A.

  • Bearings – Anti‑friction, oil bath or oil mist. For lean amine at 120°C, bearing housing with cooling fan or water jacket is recommended.

  • Flush plans – Plan 11 standard. Plan 13 (suction recirculation) optional for horizontal seal chamber. Plan 23 for hot amine.

Typical performance range

ParameterValue
Flow rate10 – 2500 m³/h
HeadUp to 250 m
TemperatureUp to 120°C (higher on request)
Pressure ratingUp to 50 bar (depending on absorber pressure)
NPSHr (with inducer)As low as 0.5 m
Speeds1450 / 2900 / 3600 rpm

Typical applications

  • Lean amine from regenerator to absorber (main circulation).

  • Lean amine to trim cooler or filter before absorber.

  • Lean amine for split‑flow configurations in large gas plants.

  • Lean amine transfer between storage and unit (make‑up).

Why choose our API 610 OH2 lean amine pump?

  • Full API 610 compliance – Performance test, mechanical run test, NPSH test (with inducer) included.

  • Corrosion resistant materials – Full stainless steel or duplex ensures long life in hot, corrosive amine.

  • Low NPSH design – Inducer prevents cavitation, which degrades amine and shortens pump life.

  • Energy efficient – High efficiency (-5-10% higher than off‑the‑shelf industrial pumps) reduces operating cost.

  • Easy maintenance – Back pull‑out with cartridge seals minimizes downtime.

  • Short lead time – Standard corrosion‑resistant pumps available ex‑stock or 6-8 weeks.

  • Global spare parts support – Impellers, shafts, seals, bearings, casings shipped worldwide.

Quality assurance

  • ISO 9001:2015 certified.

  • API 610 mechanical run test (4 hours minimum) with vibration and bearing temperature monitoring.

  • NPSH test verification (if inducer ordered).

  • Hydrostatic test of casing.

  • Material traceability EN 10204 3.1 / 3.2.

  • PMI (positive material identification) for alloy components.

  • NDE – MT, PT, UT as required.

How to specify your lean amine pump

Please provide: flow (m³/h), head (m), operating temperature (°C), NPSHa (m), amine type (DEA, MEA, MDEA etc.), concentration, presence of solids (e.g., iron sulfide), required material (316SS / duplex / Alloy 20), and any emission regulations (zero leakage). We will recommend inducer (yes/no), impeller size, seal type and flush plan, bearing cooling, and driver details.