A vacuum residue pump (also called VTB pump, vacuum resid pump, or reduced crude pump) handles the heaviest fraction from the vacuum distillation unit – a high‑viscosity, high‑temperature liquid containing asphaltenes, metals, and often small amounts of coke fines or catalyst particles. This pump is one of the most demanding refinery services. Our API 610 BB2 multistage, axially split, between‑bearings pump is specifically engineered for this severe duty. This design fully complies with API 610 11th/12th edition (ISO 13709) .
Structure match check: API 610 BB2 is defined as a horizontal, axially split, multistage, between‑bearings pump with centerline support for high temperature. This is the correct standard type for vacuum residue service because:
Axially split casing allows full access to clean heavy, sticky residue deposits without disturbing suction/discharge piping.
Multistage design (typically 2-5 stages) provides the high head (up to 600 m) required to feed cokers, visbreakers, or send residue to storage at high backpressure.
Between‑bearings rotor offers superior rigidity and stability under high radial loads from high viscosity fluid.
Centerline support accommodates thermal expansion at operating temperatures up to 400°C.
Why API 610 BB2 for vacuum residue duty?
High head capability – Vacuum residue often needs heads of 200-600 m to overcome piping losses, control valve pressure drops, and elevation to downstream units. BB2 multistage achieves this without excessive speed or oversizing.
High viscosity handling – Vacuum residue can range from 100 cSt to over 5000 cSt at pumping temperature (typically 300-400°C). BB2 pump selection uses viscosity correction factors (HI standard) for head, flow, efficiency, and NPSH. Speed reduction (via VSD or gearbox) may be required.
Axially split casing for easy cleaning – Heavy residue tends to deposit coke and asphaltenes inside the casing. Removing the top half allows thorough cleaning and inspection without breaking pipe flanges.
High temperature capability – Centerline support, water‑cooled bearing housings, and elevated seal chambers with Plan 23 (cooled recirculation) or Plan 32 (external flush) prevent coking and maintain seal life.
Abrasion resistance – Vacuum residue may contain catalyst fines or coke particles (0.1-2 mm). Hardened wetted parts (12% chrome, Stellite wear rings) extend service life.
Heavy duty bearings – Pure oil mist lubrication recommended. Water cooled bearing housings for ambient heat radiation above 200°C.
Flow range – 50 to 3000 m³/h, head up to 600 m.
Temperature – Up to 400°C (API 610 material class I-4 or I-5).
Key design features for vacuum residue service
Casing – Axially split, with centerline support. Material options: carbon steel (WCB up to 425°C, WCC up to 425°C, WC6 for higher temperature). Pressure rating ASME Class 300 or 600.
Impellers – Enclosed radial design. First stage may be double‑suction for thrust balance. Hardened 12% chrome (CA6NM) with Stellite wear rings. Each impeller dynamically balanced.
Shaft – Through‑shaft design with close fitting keys or hydraulic fit. Material: AISI 4140, 17-4PH, or 12% chrome, hardened for wear.
Wear rings – Replaceable hardened stainless or Stellite, to protect casing and impellers from abrasion.
Bearings – Tilting pad journal bearings + Kingsbury type thrust bearing. Pure oil mist lubrication standard; forced lube optional. Cooling water jacket on bearing housing.
Sealing – API 682 Plan 23 (cooled recirculation) for clean residue; Plan 32 (external flush with clean oil) for dirty residue; Plan 62 with quench to prevent coke at seal face. Double seals with barrier fluid for zero emissions (increasingly required).
Steam/jacket provisions – Casing drains and seal chambers can be steam traced for preheat before start‑up.
Material class – Per API 610, vacuum residue typically requires material class S-4 (carbon steel with 12% chrome trim) or S-5 (alloy steel with 12% chrome trim), depending on H₂S and chlorine content. NACE MR0175 available for sour service.
Typical performance range
| Parameter | Value |
|---|---|
| Flow rate | 50 – 3000 m³/h |
| Head | Up to 600 m |
| Temperature | Up to 400°C |
| Discharge pressure | Up to 100 bar (depending on stages) |
| Viscosity at pumping temp | Up to 5000 cSt (select lower speed) |
| Solids passage | Up to 1 mm (with hardened parts) |
| Stages | 2 to 5 (typical) |
Typical applications
Vacuum residue feed to delayed coker – High head, moderate flow.
Vacuum residue feed to visbreaker – Lower head but high temperature.
Vacuum residue transfer to storage or shipping – Long distance, high pressure.
Heavy fuel oil blending – Pumping resid to blending header.
Asphalt / bitumen processing – For vacuum residue with low penetration index.
Why choose our API 610 BB2 vacuum residue pump?
Full API 610 compliance – Type BB2 verified. Performance test, mechanical run test, NPSH test (corrected for viscosity) as required.
High viscosity expertise – Correct hydraulic design using HI viscosity correction ensures reliable performance at actual duty point.
Abrasion and coking resistance – Hardened impellers, wear rings, and seal flush plans (Plan 23/32) maximize uptime.
Easy cleaning – Axially split casing allows full access without removing piping. Steam tracing option for preheating.
Short lead time – Standard frame sizes with custom hydraulics available in 10-14 weeks (vacuum residue pumps are typically engineered to order).
Global spare parts support – Casing halves, impellers, shafts, wear rings, bearings, seals, and stage pieces shipped worldwide.
Lower total cost – Competitive price + longer MTBR (with proper material selection and seal plan) + less frequent decoking.
Quality assurance
ISO 9001:2015 certified.
API 610 mechanical run test (minimum 4 hours) with vibration and bearing temperature monitoring. Test at ambient using reduced viscosity fluid (or with full temperature simulation if specified).
Hydrostatic test of casing at 1.5x working pressure.
Material traceability EN 10204 3.1 / 3.2.
NDE – MT, PT, UT, RT as required.
Impeller and rotor dynamic balancing per API 610 (grade 2.5 or better).
Hardness testing for wear components.
How to specify your vacuum residue pump
Please provide: flow (m³/h), head (m), operating temperature (°C), viscosity at pumping temperature (cSt), density (kg/m³), NPSHa (m), solids content and size (e.g., catalyst fines, coke), H₂S and chlorides content (for material selection), required material class (if known), and any emission regulation requirements (zero leakage seals). Also indicate if the pump will be used for coker feed (high pressure, high temperature) or transfer duty. We will recommend number of stages, impeller diameter, speed, material class (S‑4, S‑5, etc.), seal plan (Plan 23/32/52/53), heating/tracing provisions, bearing lubrication (oil mist standard), and driver details.
Contact us
For a quotation or technical discussion on vacuum residue pumps (API 610 BB2) :
info@hyrig.com
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.