HYRIG can supply the API 6D fire safe ball valve range. The API 6D fire safe ball valve is designed to maintain sealing integrity even if the primary soft seats (PTFE) are destroyed by high temperatures. It utilizes a secondary metal-to-metal seal to meet API 607 requirements.
| Component | Standard Design | Fire-Safe Feature |
|---|---|---|
| Seat Ring | PTFE / RPTFE | Secondary metal seat provides shutoff after PTFE degrades. |
| Stem Seal | O-ring / PTFE packing | Graphite packing maintains seal under high heat. |
| Body Gasket | PTFE | Spiral wound / Graphite ensures flange tightness. |
| Anti-Static | Standard | Prevents static build-up during operation. |
| Dimension | Standard |
|---|---|
| Face-to-Face | ASME B16.10 |
| Flange Ends | ASME B16.5 / B16.47 |
| Butt Weld Ends | ASME B16.25 |
In a standard valve, the soft PTFE seats provide the primary seal. In a fire event, the PTFE seats melt or degrade. The fire-safe design incorporates a secondary metal seat that automatically engages the ball when the PTFE is lost. Similarly, the stem packing is upgraded to graphite, and the body gasket is designed to withstand extreme heat. This ensures both internal (seat) and external (stem/body joints) leakage is minimized.
When replacing standard soft-seated valves in high-risk areas, verify: 1. API 607 certification for the exact size, class, and material. 2. Secondary seal material (metal-to-metal). 3. Stem packing material (graphite). 4. Cavity relief design for trapped pressure.
Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.
Need a fire-safe valve for your specific pipeline? Share your pressure class, medium, and certification requirements, and our engineers will confirm the correct configuration.
Q: How does a fire-safe ball valve work?
A fire-safe valve uses a secondary metal-to-metal seal. If the PTFE seat melts during a fire, the metal components contact each other to maintain a seal and prevent the spread of flammable media.
Q: What standard covers fire-safe testing?
API 607 is the standard fire test for quarter-turn valves with soft seats. API 6FA is the equivalent standard for API 6D valves.
Q: Can this valve be repaired after a fire?
If the valve has been exposed to fire, the soft seals and potentially the metal components will need inspection. The valve should be disassembled and parts replaced as necessary before returning to service.
For API 6D fire safe ball valve selection, contact HYRIG: info@hyrig.com