Butane Pump | API 610 VS6 Submerged In-Tank Pump | China VS6 Pump Manufacturer

QR code
share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
copy Link
Facebook
X
LinkedIn
Pinterest
Line
Tumblr
API 610 VS6 vertical submerged pump for butane (LPG) service. Fully seal-less design, motor immersed in butane. Top-pull withdrawal for easy maintenance. Zero leakage, low NPSH. For bullet tanks, spheres, and pressurized storage. China VS6 pump manufacturer.

Conatct For Details
DetailReview(0)Additional

A butane pump must handle liquefied butane (a hydrocarbon with moderate vapour pressure, boiling point approximately -1°C) safely, with zero leakage and reliable operation from pressurized storage. Our API 610 VS6 submerged in-tank pump is specifically engineered for butane, commercial LPG, and high-butane blends. This design fully complies with API 610 11th/12th edition (ISO 13709) for vertical submerged pumps.

Structure match check: API 610 VS6 is defined as a vertical, single-casing, submerged pump where the driver and hydraulics are fully immersed in the pumped liquid. There is no external shaft seal. This matches exactly the requirements for butane in-tank pumping: zero leakage, intrinsic safety, and low NPSH (especially important for winter operation or when tank pressure is low).

Why API 610 VS6 for butane duty?

  • Zero dynamic seal – Eliminates mechanical shaft seals completely. The motor runs submerged in oxygen-free butane, so there is no external leakage path. Meets strict environmental regulations (LDAR, EPA, EU Seveso).

  • Intrinsically safe – Submerged motor operates inside butane liquid (vapour-free). No explosion risk, no external purging required. ATEX / IECEx Zone 0 ready.

  • Top-pull maintenance – The entire pump assembly (hydraulics + motor) can be withdrawn through the tank top nozzle without emptying or degassing the tank. Downtime reduced by over 70% compared to external pumps.

  • Low NPSH capability – Optional first-stage inducer reduces NPSHr to below 1 m, preventing cavitation and vapour lock – important for butane during cold weather or when tank pressure drops.

  • Wide performance range – Handles pure butane, commercial LPG (propane/butane mixes), and high-butane blends with varying vapour pressure.

  • High reliability – No seal wear, no fugitive emissions, no external mechanical failures.

Key design features (API 610 VS6 for butane)

  • Single casing construction – Outer can withstand tank pressure (up to 2.5 MPa / 25 bar standard; higher on request). Inner diffuser casing contains multistage impellers.

  • Submerged permanent magnet synchronous motor (PMSM) – Self-cooled by liquid butane. High efficiency (over 85% at design point).

  • Bearings – Carbon-graphite or ceramic-lined, lubricated by butane. No external lube system.

  • Inducer on first stage – Optional but recommended for butane if NPSHa is marginal (e.g., storage near vapour pressure).

  • Wetted materials – Ductile iron or carbon steel for clean butane. Stainless steel 316 for sour butane (H₂S) or higher corrosion resistance. NACE MR0175 optional.

  • Temperature range – -30°C to +50°C (butane typically stored near ambient, but can be colder in winter).

  • Discharge pressure – Up to 2.5 MPa (25 bar) standard; higher on request.

  • Flow range – 5 to 800 m³/h.

  • Head range – Up to 500 m (multistage design; butane typically requires lower head than propane due to lower vapour pressure).

Typical applications

  • Butane bullet tanks – Mounded or above-ground pressurized vessels.

  • Spherical butane storage – High-pressure spheres in terminals.

  • Butane railcar / truck unloading – Pumping from transport tanks into storage.

  • LPG peak-shaving plants – Transfer butane or butane/propane mixtures to vaporizers.

  • Refinery butane feed – To alkylation units or blending for gasoline.

  • Butane export / import terminals – Ship loading/unloading where in-tank pumps are required.

Why choose our API 610 VS6 butane pump?

  • Full API 610 compliance – Type VS6 verified per standard. Performance test, NPSH test, mechanical run test included.

  • Zero leakage – No mechanical seal, no packing, no fugitive emissions – best available technology (BAT) for butane.

  • Low NPSHr – Inducer option allows operation at low NPSHa (below 1 m), preventing pump cavitation damage.

  • Easy installation – Complete assembly supplied with top flange ready to bolt to tank nozzle.

  • Short lead time – Standard sizes (e.g., 6”, 8”, 10” discharge) available ex-stock; custom hydraulics 8-12 weeks.

  • Global spare parts support – Impellers, inducer, bearings, motor stator, and complete replacement cartridges shipped worldwide.

  • Lower total cost – Competitive initial price plus zero seal maintenance and long MTBR.

Quality assurance

  • ISO 9001:2015 certified manufacturing.

  • API 610 mechanical run test (minimum 4 hours) with vibration and bearing temperature monitoring.

  • NPSH test with inducer (if specified) to verify cavitation performance.

  • Hydrostatic test of outer can and pressure boundary.

  • Material traceability EN 10204 3.1 / 3.2.

  • NDE – MT, PT, UT as required.

How to specify your butane pump

Please provide: flow (m³/h), head (m), operating temperature (°C), tank pressure (bar or MPa), NPSHa available (m), butane purity (pure, commercial LPG, or H₂S content), and tank type (bullet, sphere, etc.). We will recommend pump size, stage count, inducer (optional), material class, and motor rating.

Contact us

For a quotation or technical discussion on butane pumps (API 610 VS6) :

info@hyrig.com


Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code