A condensate pump must handle hot water or steam condensate at temperatures up to 200°C, often with low net positive suction head (NPSH) and potential for cavitation. Our API 610 OH2 and VS4 pumps cover two distinct installation configurations – horizontal above-ground and vertical suspended (in-pit or tank-mounted). Both designs fully comply with API 610 11th/12th edition (ISO 13709) , with different structural types as defined by the standard.
API 610 OH2 – Horizontal Condensate Pump
Structure match check: API 610 OH2 is defined as a horizontal, single-stage, overhung pump with foot-mounted casing, back pull-out design, and centerline support (for high temperature). This is suitable for above-ground condensate service where NPSHa is adequate and horizontal layout is preferred.
Why OH2 for condensate?
Horizontal, easy access for maintenance – back pull-out allows seal and rotor removal without disturbing piping.
High temperature capability – Centerline support handles thermal expansion up to 200°C typical (higher with special materials).
Low NPSH options – Inducer or oversized impeller eye reduces NPSHr, preventing cavitation on hot condensate.
API 682 seal compatibility – Single or tandem mechanical seals with proper flush plans (Plan 11, 13, 21, 23) for hot water.
Flow range – 5 to 1500 m³/h, head up to 250 m.
Typical OH2 applications
Power plant condensate extraction (above-ground installation)
Industrial boiler condensate return systems
HRSG condensate transfer
District heating condensate recovery
API 610 VS4 – Vertical Condensate Pump
Structure match check: API 610 VS4 is defined as a vertical, single-casing, rigid shaft, suspended pump with discharge head above the pit cover. It is designed for installation in sumps, tanks, or pits where flooded suction or low NPSH is required. This matches condensate applications where liquid level is below grade or NPSH is extremely low.
Why VS4 for condensate?
Vertical suspended – Installed in a pit or tank, allowing the pump to be fully immersed in condensate, ensuring flooded suction.
Extremely low NPSHr – Because the impeller is submerged, cavitation is virtually eliminated, ideal for hot condensate near boiling point.
Space saving – Small footprint, no external suction piping required.
Column pipe construction – For deeper pits (up to 6 m or more), with intermediate bearings.
Flow range – 10 to 3000 m³/h, head up to 150 m.
Easy maintenance – Entire pump assembly pulls out vertically without emptying the pit.
Typical VS4 applications
Power plant hotwell / condenser pit – Condensate extraction from turbine condenser hotwell.
Steam trap receiver pits – Collecting and pumping condensate from multiple steam traps.
Industrial condensate collection tanks – Where NPSHa is below 1 meter.
Combined cycle HRSG – Low-level condensate pumping.
Comparison & Selection Guide
| Feature | OH2 (Horizontal) | VS4 (Vertical Suspended) |
|---|---|---|
| API 610 type | OH2 – horizontal overhung, foot-mounted | VS4 – vertical single-casing, rigid shaft, suspended |
| Installation | Above ground on baseplate | In pit / tank / sump, submerged |
| NPSH requirement | Requires moderate NPSHa (inducer optional) | Very low (submerged impeller) |
| Space | Requires horizontal footprint | Small footprint, requires pit depth |
| Maintenance | Back pull-out | Top pull-out (vertical removal) |
| Typical max head | 250 m | 150 m |
| Typical max flow | 1500 m³/h | 3000 m³/h |
| Best for | Above-grade, moderate NPSHa, high head | Low NPSHa, pit installation, high flow |
Key design features for both OH2 & VS4 (condensate service)
High temperature hydraulics – Designed for water up to 200°C. Thermal expansion allowances built in.
Cavitation prevention – Inducer (OH2) or submerged impeller (VS4) ensures reliable operation on saturated or near-saturated water.
Sealing – API 682 mechanical seals with Plan 11 (recirculation) or Plan 23 (jacketed for high temp). Tandem seals if emission control is required (though water service typically not fugitive).
Materials – Cast iron or carbon steel casing. Stainless steel 304/316 impeller and shaft for corrosion resistance. Bronze fitted options for better wear.
Bearings – OH2: oil lubricated anti-friction bearings. VS4: product-lubricated carbon graphite or water-lubricated rubber bearings with line shaft bearings for deeper settings.
Motor – Standard TEFC motor (OH2) or vertical hollow‑shaft / solid‑shaft motor (VS4).
Why choose our API 610 condensate pumps?
Full API 610 compliance – Both OH2 and VS4 types verified per standard.
Low life cycle cost – High efficiency, reliable sealing, and robust hydraulics reduce maintenance.
Short lead time – Standard sizes ex‑stock; custom designs with competitive delivery.
Global spare parts support – Impellers, shafts, bearings, seals, and column assemblies shipped worldwide.
Application expertise – We help select OH2 or VS4 based on your pit depth, NPSHa, flow, head, and temperature.
Quality assurance (both types)
ISO 9001:2015 certified.
API 610 mechanical run test with vibration & bearing temperature monitoring.
NPSH test verification (OH2 with inducer; VS4 as standard due to submerged design).
Hydrostatic test of pressure boundaries.
Material traceability EN 10204 3.1 / 3.2.
How to specify your condensate pump
Please provide: flow (m³/h), head (m), temperature (°C), NPSHa available (m), installation type (above ground or pit/sump), pit depth (if VS4), and fluid cleanliness (e.g., debris content). We will recommend the correct API 610 type (OH2 or VS4), material class, seal plan, and driver details.
Contact us
For a quotation or technical discussion on condensate pumps (API 610 OH2 or VS4) :
info@hyrig.com