HYRIG can supply Casappa multiple gear pumps in tandem and triple configurations. The Casappa Polaris series can be coupled together to provide multiple independent flow circuits from a single drive shaft, with combinations including PLP 10/10, PLP 20/20, PLP 30/30, and cross-series arrangements.
Conatct For Details
DetailReview(0)Additional

Casappa Multiple Gear Pumps | PLP Tandem & Triple

HYRIG can supply Casappa multiple gear pumps in tandem and triple configurations. The Casappa Polaris series can be coupled together to provide multiple independent flow circuits from a single drive shaft, with combinations including PLP 10/10, PLP 20/20, PLP 30/30, and cross-series arrangements.

Key Facts

ParameterValue
TypesTandem (2-stage) and triple (3-stage)
CombinationsPLP 10/10, PLP 20/20, PLP 30/30, PLP 30/20, PLP 30/10, PLP 20/10
Max pressureLimited by drive shaft torque
Max speedLowest rated speed of individual stages
Port arrangementCommon inlet or separated stages
Mounting flangesSame as single pumps

Multiple Pump Configurations

ConfigurationStagesTypical Application
PLP 10/102Compact dual-circuit systems
PLP 20/202Dual-circuit mobile hydraulics
PLP 20/102High/low flow combination
PLP 30/302Heavy-duty dual-circuit systems
PLP 30/202High/medium flow combination
PLP 30/102High/low flow combination
Triple combinations3Multi-function hydraulic systems

Data source: Technical data table

Dimensions

Drive Shaft Torque Limits

ConfigurationMax Torque (Nm)Max Torque (lbf in)
PLP 10/1030266
PLP 20/20110974
PLP 30/301701505

Port Arrangement

ArrangementDescription
StandardSeparate inlet and outlet for each stage
Common inletSingle inlet feeding all stages
Separated stagesIndependent inlet/outlet per stage

Structure / Working Principle

Casappa multiple gear pumps consist of two or three individual pump stages coupled in series on a common drive shaft. Each stage has its own inlet and outlet, allowing independent flow circuits from a single power source. The first stage (closest to the drive) transmits torque to the subsequent stages through the connecting shaft.

When selecting a multiple pump, the input power requirements of each section must be considered. The section with the greater power requirement must be at the drive shaft end. The maximum rotational speed is limited by the lowest rated speed of the individual units incorporated.

Cross-Reference & Replacement

Looking to replace a Casappa multiple pump? Here's what to check:/n/n1. Stage displacements — Confirm each stage's cm³/rev matches your flow requirements.

  1. Stage order — Verify which stage is at the drive end (higher power requirement).
  2. Mounting flange — Confirm the bolt pattern matches your existing bracket.
  3. Drive shaft — Verify shaft type and keyway dimensions.
  4. Port arrangement — Check whether common inlet or separated stages are required.
  5. Torque limit — Confirm total torque does not exceed drive shaft maximum.

Applications

Casappa multiple gear pumps are commonly used in:/n/n- Mobile hydraulic systems — dual-circuit steering and implement control on tractors and loaders

  • Industrial power units — multi-function press circuits, injection molding machine actuators
  • Material handling — forklift mast, tilt, and steering circuits from a single pump
  • Municipal equipment — snow plow blade and spreader circuits, sweeper brush and suction drives
Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.

Selection Support

Not sure which multiple pump configuration fits your system? Send HYRIG your required flow rates (L/min) for each circuit, operating pressures (bar), and mounting constraints. Our engineers will confirm the correct stage combination and model code.

Frequently Asked Questions

Q: What is the maximum torque for a Casappa multiple pump?
A: Torque limits depend on the drive shaft: PLP 10/10 = 30 Nm, PLP 20/20 = 110 Nm, PLP 30/30 = 170 Nm.

Q: How do I calculate total torque for a multiple pump?
A: Sum the torque of each stage: M_total = M1 + M2 + M3. The total must not exceed the drive shaft maximum torque.

Q: Can I order a custom multiple pump configuration?
A: Yes. Casappa multiple pumps can be configured with different stage displacements, flange types, shaft options, and port arrangements. Contact HYRIG with your requirements.

Q: What is the lead time for Casappa multiple pumps?
A: Standard lead time is 6–8 weeks for most configurations. Urgent downtime situations can be prioritized.

Q: What does the model code PLP 20/10 mean?
A: PLP 20/10 indicates a tandem pump with a PLP 20 stage at the drive end and a PLP 10 stage at the rear. See Casappa How to Order for full code breakdown.

Q: Can HYRIG support repair or replacement of a complete multiple pump?
A: Yes. HYRIG supplies complete Casappa multiple pump assemblies. Send us the nameplate details for confirmation.

Contact

For Casappa multiple gear pump selection, contact HYRIG: info@hyrig.com

Explore: Casappa PLP 10 Gear Pumps, Casappa PLP 20 Gear Pumps, Casappa PLP 30 Gear Pumps, Casappa How to Order.

Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit